Optimal placement and decentralized robust vibration control for spacecraft smart solar panel structures

被引:26
|
作者
Jiang, Jian-ping [1 ]
Li, Dong-xu [1 ]
机构
[1] Natl Univ Def Technol, Coll Aerosp & Mat Engn, Changsha 410073, Hunan, Peoples R China
关键词
MATRIX INEQUALITY APPROACH; SUPPRESSION; FEEDBACK; ACTUATORS; SYSTEMS; DESIGN;
D O I
10.1088/0964-1726/19/8/085020
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The decentralized robust vibration control with collocated piezoelectric actuator and strain sensor pairs is considered in this paper for spacecraft solar panel structures. Each actuator is driven individually by the output of the corresponding sensor so that only local feedback control is implemented, with each actuator, sensor and controller operating independently. Firstly, an optimal placement method for the location of the collocated piezoelectric actuator and strain gauge sensor pairs is developed based on the degree of observability and controllability indices for solar panel structures. Secondly, a decentralized robust H-infinity controller is designed to suppress the vibration induced by external disturbance. Finally, a numerical comparison between centralized and decentralized control systems is performed in order to investigate their effectiveness to suppress vibration of the smart solar panel. The simulation results show that the vibration can be significantly suppressed with permitted actuator voltages by the controllers. The decentralized control system almost has the same disturbance attenuation level as the centralized control system with a bit higher control voltages. More importantly, the decentralized controller composed of four three-order systems is a better practical implementation than a high-order centralized controller is.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Optimal solar panel placement in mobile edge computing
    Vaezpour, Seyed Yahya
    INTERNATIONAL JOURNAL OF AD HOC AND UBIQUITOUS COMPUTING, 2021, 37 (02) : 61 - 73
  • [32] Study of hierarchical decentralized vibration control of structures
    Zhou, Qingsheng
    Duan, Zhongdong
    SMART STRUCTURES AND MATERIALS 2006: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL , AND AEROSPACE SYSTEMS, PTS 1 AND 2, 2006, 6174
  • [33] Robust adaptive vibration control of an underactuated flexible spacecraft
    MoradiMaryamnegari, H.
    Khoshnood, A. M.
    JOURNAL OF VIBRATION AND CONTROL, 2019, 25 (04) : 834 - 850
  • [34] ROBUST ATTITUDE AND VIBRATION CONTROL OF A NONLINEAR FLEXIBLE SPACECRAFT
    Malekzadeh, Maryam
    Naghash, Abolghasem
    Talebi, H. A.
    ASIAN JOURNAL OF CONTROL, 2012, 14 (02) : 553 - 563
  • [35] OPTIMAL SENSOR PLACEMENT IN DECENTRALIZED CONTROL-SYSTEMS
    OLOOMI, H
    SAWAN, ME
    INTERNATIONAL JOURNAL OF SYSTEMS SCIENCE, 1989, 20 (06) : 939 - 943
  • [36] Optimal active random vibration control for smart truss structures based on reliability
    Gao, W.
    Zhang, N.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2007, 221 (11) : 1299 - 1308
  • [37] Symmetries in the optimal control of solar sail spacecraft
    Kim, M
    Hall, CD
    CELESTIAL MECHANICS & DYNAMICAL ASTRONOMY, 2005, 92 (04): : 273 - 293
  • [38] Symmetries in the Optimal Control of Solar Sail Spacecraft
    M. Kim
    C. D. Hall
    Celestial Mechanics and Dynamical Astronomy, 2005, 92 : 273 - 293
  • [39] OPTIMAL-CONTROL OF A SPACECRAFT WITH A SOLAR SAIL
    GULYAEV, VI
    KOSHKIN, VL
    VASILEV, AB
    INTERNATIONAL APPLIED MECHANICS, 1994, 30 (09) : 721 - 726
  • [40] Decentralized and distributed MIMO H-infinity robust control of vibration suppression of planar structures
    Sika, Z.
    Hromcik, M.
    Svoboda, F.
    Volech, J.
    Zavrel, J.
    Karlicek, J.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2018) / INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2018), 2018, : 309 - 323