CUBATURES FOR MEDIUM-SIZED PLUS ENERGY BUILDINGS

被引:2
|
作者
Sick, Friedrich [1 ]
Ross, Lioba [2 ]
机构
[1] HTW Berlin Univ Appl Sci, Renewable Energies, Wilhelminenhofstr 75A, D-12459 Berlin, Germany
[2] Stahl Weiss, Basler Str 55, D-79100 Freiburg, Germany
来源
JOURNAL OF GREEN BUILDING | 2017年 / 12卷 / 02期
关键词
building surfaces; power generation potential; building shape and energy demand; photovoltaic facades; solar energy; dynamic building simulations;
D O I
10.3992/1943-4618.12.2.28
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
On the basis of dynamic building simulations within a maximal realistic framework, it may be useful with respect to the overall energy balance to dispense with pursuing a minimal surface/volume ratio of buildings-thus minimizing heat losses across the building shell-in favor of solar energy use. The specific use of the building (here: office or residential) plays a crucial role. Balancing the energy demand for heating and cooling and a possible photovoltaic yield, a surplus is possible in all cases under investigation. Long, low unobstructed buildings perform best due to large portions of roof area suitable for solar energy use. For tall buildings with less roof area, parts of the facades may be used for solar applications which makes them also perform better than compact designs. If the total energy demand including auxiliary energy for HVAC and especially electricity for the office and residential usages, respectively, is considered, compact cubatures of the size considered here (about 3500 m(2)) are not capable of providing positive energy balances. Residential usage performs worse than office use. Investigations are performed for the climatic conditions of Berlin, Germany.
引用
收藏
页码:28 / 37
页数:10
相关论文
共 50 条
  • [31] Alternative energy as a tool for the development of small and medium-sized enterprises in Russia
    Teslyuk, L.
    Boyarinov, A.
    Dukmasova, N.
    Plastinina, I.
    Romanova, O.
    INTERNATIONAL CONFERENCE ON SUSTAINABLE CITIES, 2018, 2018, 177
  • [32] Study of the energy intensity by built areas in a medium-sized Spanish hospital
    Juan Aunión-Villa
    Miguel Gómez-Chaparro
    Justo García-Sanz-Calcedo
    Energy Efficiency, 2021, 14
  • [33] ENERGY ANALYSIS ON SMALL TO MEDIUM-SIZED H-BONDED COMPLEXES
    DIVE, G
    DEHARENG, D
    GHUYSEN, JM
    THEORETICA CHIMICA ACTA, 1993, 85 (06): : 409 - 421
  • [34] ORGANIZATION OF MAINTENANCE IN A MEDIUM-SIZED ENTERPRISE
    GEIGER, F
    STAHL UND EISEN, 1981, 101 (22): : 47 - 47
  • [35] CONTROL OF HYPERTENSION IN A MEDIUM-SIZED COMMUNITY
    DEGER, GE
    ANDERSON, JA
    WESTERN JOURNAL OF MEDICINE, 1979, 130 (02): : 184 - 187
  • [36] IT readiness in small and medium-sized enterprises
    Haug, Anders
    Pedersen, Soren Graungaard
    Arlbjorn, Jan Stentoft
    INDUSTRIAL MANAGEMENT & DATA SYSTEMS, 2011, 111 (3-4) : 490 - 508
  • [37] Performance Management in Medium-Sized Enterprises
    Wickramasinghe, Vathsala
    PERFORMANCE IMPROVEMENT QUARTERLY, 2016, 29 (03) : 307 - 331
  • [38] REACTIONS IN MEDIUM-SIZED CYCLIC SULFIDES
    OVERBERGER, CG
    RINGSDORF, H
    BARKAN, P
    LUSI, A
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1962, 84 (14) : 2814 - &
  • [39] Spectral functions for medium-sized nuclei
    Ankowski, Artur M.
    Sobczyk, Jan T.
    NEUTRINO-NUCLEUS INTERACTIONS IN THE FEW-GEV REGION, 2007, 967 : 106 - 108
  • [40] ACTION MODEL FOR MEDIUM-SIZED FIRMS
    NEUBERT, H
    BETRIEB, 1973, 26 (49): : 2409 - 2411