Study of long-term biocompatibility and bio-safety of implantable nanogenerators

被引:67
|
作者
Li, Jun [1 ]
Kang, Lei [2 ,3 ]
Yu, Yanhao [1 ]
Long, Yin [1 ]
Jeffery, Justin J. [6 ]
Cai, Weibo [2 ,4 ,5 ,6 ]
Wang, Xudong [1 ]
机构
[1] Univ Wisconsin, Dept Mat Sci & Engn, 1509 Univ Ave, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53705 USA
[3] Peking Univ, Hosp 1, Dept Nucl Med, Beijing 100034, Peoples R China
[4] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[5] Univ Wisconsin, Sch Pharm, Madison, WI 53705 USA
[6] Univ Wisconsin, Carbone Canc Ctr, Madison, WI 53705 USA
基金
美国国家卫生研究院;
关键词
Implantable Nanogenerator; Biocompatibility; In Vivo imaging; PVDF; Biomechanical energy harvesting; HARVESTING ENERGY; THIN-FILM; DRIVEN;
D O I
10.1016/j.nanoen.2018.07.008
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Implantable nanogenerator (i-NG) has shown great promises for enabling self-powered implantable medical devices (IMDs). One essential requirement for practical i-NG applications is its long-term bio-compatibility and bio-safety. This paper presents a systematic study of polydimethylsiloxane (PDMS) and PDMS/Parylene-C packaged polyvinylidene fluoride (PVDF) NGs implanted inside female ICR (Institute of Cancer Research) mice for up to six months. The PVDF NG had a stable in vitro output of 0.3 V when bended for 7200 cycles and an in vivo output of 0.1 V under stretching. Multiple advanced imaging techniques, including computed tomography (CT), ultrasound, and photoacoustic were used to characterize the embedded i-NGs in vivo. The i-NGs kept excellent adhesion to the adjacent muscle surface, and exhibited stable electrical output during the entire examine period. No signs of toxicity or incompatibility were observed from the surrounding tissues, as well as from the whole body functions by pathological analyses and blood and serum test. The PDMS package was also able to effectively insulate the i-NG in biological environment with negligible stray currents at a pA scale. This series of in-vivo and in-vitro studies confirmed the biological feasibility of using i-NG in vivo for biomechanical energy harvesting.
引用
收藏
页码:728 / 735
页数:8
相关论文
共 50 条
  • [21] LONG-TERM SAFETY AND BIOCOMPATIBILITY OF THE COHEREX WAVECRESTTM LEFT ATRIAL APPENDAGE OCCLUDER IN A CANINE MODEL
    Cheng, Yanping
    McGregor, Jennifer
    Edmiston, Daryl
    Sommer, Robert
    Gray, William
    Yi, Geng-Hua
    Conditt, Gerard
    Rousselle, Serge
    Granada, Juan
    Kaluza, Greg
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1677 - A1677
  • [22] Long-Term Implantable Medical Wireless Telemetry
    Topsakal, Erdem
    [J]. 2017 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2017, : 1845 - 1846
  • [23] LONG-TERM USE OF AN IMPLANTABLE VENOUS CATHETER
    PERSSON, B
    JEPPSSON, B
    HELLSTROM, M
    WESTHOLM, D
    BENGMARK, S
    [J]. EUROPEAN JOURNAL OF CANCER, 1990, 26 (07) : 853 - 854
  • [24] IMPLANTABLE TELEMETRY SYSTEM FOR LONG-TERM EMG
    MARQUES, M
    DUTOURNE, B
    [J]. BIOTELEMETRY, 1977, 4 (01) : 28 - 33
  • [25] THE LONG-TERM RESULTS OF THE AUTOMATIC IMPLANTABLE DEFIBRILLATOR
    LEENHARDT, A
    THOMAS, O
    BEL, A
    BIZOT, J
    COUMEL, P
    SLAMA, R
    [J]. ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1994, 87 (11): : 1617 - 1622
  • [26] Safety of long-term doxycycline administration: a retrospective study
    Lee, J.
    Kim, E. J.
    Park, H. S.
    Yoon, H. S.
    Cho, S.
    [J]. HONG KONG JOURNAL OF DERMATOLOGY & VENEREOLOGY, 2017, 25 (03): : 109 - 114
  • [27] Study evaluates long-term efficacy and safety of alprostadil
    Spivack, AP
    [J]. AMERICAN FAMILY PHYSICIAN, 1997, 56 (08) : 2073 - 2073
  • [28] A long-term in vitro biocompatibility study of a biodegradable polyurethane and its degradation products
    van Minnen, B
    Stegenga, B
    van Leeuwen, MBM
    van Kooten, TG
    Bos, RRM
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2006, 76A (02) : 377 - 385
  • [29] Long-term transcutaneous neuromuscular electrical stimulation in patients with bipolar sensing implantable cardioverter defibrillators: A pilot safety study
    Crevenna, R
    Wolzt, M
    Fialka-Moser, V
    Keilani, M
    Nuhr, M
    Paternostro-Sluga, T
    Pacher, R
    Mayr, W
    Quittan, M
    [J]. ARTIFICIAL ORGANS, 2004, 28 (01) : 99 - 102
  • [30] Preclinical safety study of a fully implantable, sub-scalp ring electrode array for long-term EEG recordings
    Benovitski, Yuri B.
    Lai, Alan
    Saunders, Alexia
    McGowan, Ceara C.
    Burns, Owen
    Nayagam, David A. X.
    Millard, Rodney
    Harrison, Mark
    Rathbone, Graeme D.
    Williams, Richard A.
    May, Clive N.
    Murphy, Michael
    D'Souza, Wendyl J.
    Cook, Mark J.
    Williams, Chris E.
    [J]. JOURNAL OF NEURAL ENGINEERING, 2022, 19 (03)