Determination of nitrobenzene in wastewater using a hanging mercury drop electrode

被引:30
|
作者
Liang, Shu-Xuan [1 ]
Zhang, Huan-Kun [1 ]
Lu, Da [1 ]
机构
[1] Hebei Univ, Coll Chem & Environm Sci, Baoding 071002, Peoples R China
关键词
determination; hanging mercury drop electrode; linear scan voltammetry; nitrobenzene wastewater;
D O I
10.1007/s10661-006-9366-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The determination of trace amount nitrobenzene in wastewater on a hanging mercury drop electrode was studied. The determination conditions of pH, supporting electrolyte, accumulation potential, accumulation time, and voltammetric response were optimized. The sharp peak of the nitrobenzene was appeared at 0.05 V. The peak electric current was proportional to the concentration of nitrobenzene in the range of 1.47 x 10(-5) similar to 1.0 x 10(-3) mol/l with relative standard deviations of 3.99 similar to 8.94%. The detection limit of the nitrobenzene in water was 5 x 10(-6) Mol/l. The proposed method offered low limit of determination, easy operation, the use of simple instrumentation, high sensitivity and good reproducibility. It was applied to the determination of nitrobenzene in wastewater with an average recovery of 94.0% similar to 105%. The proposed method provided fast, sensitive and sometimes real time detection of nitrobenzene.
引用
收藏
页码:331 / 337
页数:7
相关论文
共 50 条
  • [31] Adsorptive stripping voltammetric determination of quinoline yellow at the hanging mercury drop electrode
    Nevado, JJB
    Flores, JR
    Llerena, MJV
    QUIMICA ANALITICA, 1997, 16 (01): : 51 - 58
  • [32] Determination of Amitraz Pesticide by Adsorptive Stripping Voltammetry on the Hanging Mercury Drop Electrode
    Mohamed S. Ibrahim
    Mohamed S. El-Maazawi
    Khaled M. Al-Magboul
    Moustafa M. Kamal
    Microchimica Acta, 2001, 137 : 215 - 220
  • [33] CATHODIC STRIPPING VOLTAMMETRIC DETERMINATION OF PENTAMIDINE ISETHIONATE AT A HANGING MERCURY DROP ELECTRODE
    ZANONI, MVB
    FOGG, AG
    ANALYST, 1993, 118 (09) : 1163 - 1166
  • [34] DIRECT DETERMINATION OF TRACES OF SILVER IN MERCURY BY VOLTAMMETRY AT THE HANGING MERCURY DROP ELECTRODE IN ACETONITRILE MEDIUM
    GLODOWSKI, S
    KUBLIK, Z
    ANALYTICA CHIMICA ACTA, 1984, 156 (JAN) : 61 - 69
  • [35] Determination of amitraz pesticide by adsorptive stripping voltammetry on the hanging mercury drop electrode
    Ibrahim, MS
    El-Maazawi, MS
    Al-Magboul, KM
    Kamal, MM
    MIKROCHIMICA ACTA, 2001, 137 (3-4) : 215 - 220
  • [36] DETERMINATION OF CHLORIDE-IONS IN PERCHLORATE SOLUTION ON THE HANGING MERCURY DROP ELECTRODE
    PASCIAK, J
    HUREK, J
    CHEMIA ANALITYCZNA, 1982, 27 (5-6): : 401 - 409
  • [37] Cathodic stripping voltammetric determination of ceftazidime in urine at a hanging mercury drop electrode
    Ferreira, VS
    Zanoni, MVB
    Fogg, AG
    MICROCHEMICAL JOURNAL, 1997, 57 (01) : 115 - 122
  • [38] Polarographic and voltametric determination of carcinogenic nitrobiphenyls at a static and hanging mercury drop electrode
    Stepán, R
    Barek, J
    Mejstrík, V
    Moreira, JC
    Zima, J
    ANALYTICAL LETTERS, 2004, 37 (13) : 2753 - 2770
  • [39] ADSORPTIVE CATHODIC STRIPPING VOLTAMMETRIC DETERMINATION OF THEOPHYLLINE AT A HANGING MERCURY DROP ELECTRODE
    SHUBIETAH, RM
    ABUZUHRI, AZ
    FOGG, AG
    ANALYST, 1994, 119 (09) : 1967 - 1970
  • [40] DETERMINATION OF METHOPROTRYNE AND TERBUTRYN BY ADSORPTIVE STRIPPING VOLTAMMETRY ON THE HANGING MERCURY DROP ELECTRODE
    PEDRERO, M
    CALVO, V
    DEVILLENA, FJM
    PINGARRON, JM
    POLO, LM
    ANALYST, 1993, 118 (11) : 1405 - 1410