Experimental evaluation of safety performance of emergency passive residual heat removal system in HPR1000

被引:22
|
作者
Sun, D. C. [1 ]
Li, Y. [1 ]
Xi, Z. [1 ]
Zan, Y. F. [1 ]
Li, P. Z. [1 ]
Zhuo, W. B. [1 ]
机构
[1] Nucl Power Inst China, CNNC Key Lab Nucl Reactor Thermal Hydraul Technol, 328 Changshun Ave, Chengdu 610213, Peoples R China
关键词
HPR1000; EPRHR; ESPRIT; Transient experiment; Safety evaluation; TRANSIENT ANALYSES; INTEGRAL REACTOR; DESIGN; CIRCULATION; CPR1000;
D O I
10.1016/j.nucengdes.2017.04.003
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The steam generator secondary side emergency passive residual heat removal system (EPRHR) is innovatively introduced into the Hualong Pressurized Reactor (HPR1000) to enhance its safety performance in station blackout (SBO) scenarios. The Emergency Secondary Passive Residual heat removal system Integral Test facility (ESPRIT) was constructed to obtain the safety performance of EPRHR under various initial and boundary conditions. The scaling ratio of power/volume between ESPRIT and HPR1000 is 1:62.5. The resistance matching experiments were conducted in the first place to restore the prototypical pressure drop characteristics of the EPRHR. Three transient experiments, each with the duration of 72 h, were conducted under prototypical, elevated heating power and elevated resistance conditions to evaluate the safety performance of HPR1000 under SBO conditions. The experimental results reveal that the steam generator pressure decreases dramatically in the early stage after the startup of EPRHR. The safety injection rate decreases dramatically in the elevated resistance condition compared with the prototypical one. The liquid level in the cooling water tank decreases by 5.4% in the steam generator power elevation condition. The designed volume of cooling water tank satisfies the heat removal demand in SBO accident within 72 h. The heat sink possesses sufficient cooling ability under elevated power condition. The system temperature remains decreasing with the decrease of residual heat in each of the transient experiment. It is also found that effective natural circulation and continuous heat exchanger cooling always remain in three experiments. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 60
页数:7
相关论文
共 50 条
  • [1] Experimental investigation on natural circulation characteristics of emergency passive residual heat removal system in HPR1000
    Sun, D. C.
    Xi, Z.
    Li, Y.
    Zan, Y. F.
    Xiong, W. Y.
    Li, P. Z.
    Zhuo, W. B.
    [J]. PROGRESS IN NUCLEAR ENERGY, 2018, 103 : 1 - 7
  • [2] HPR1000 passive containment heat removal system
    Xing, Ji
    Sun, Zhongning
    Yu, Yong
    Ding, Ming
    [J]. Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2023, 44 (07): : 1089 - 1095
  • [3] Research on Design Method of HPR1000 Emergency Residual Heat Removal System Based on System Engineering Method
    Chen, Guocai
    Li, Feng
    Tang, Huapeng
    Qiu, Zhifang
    Dengjian
    [J]. Hedongli Gongcheng/Nuclear Power Engineering, 2021, 42 (02): : 93 - 98
  • [4] Design, Experiment, and Commissioning of the Passive Residual Heat Removal System of China's Generation III Nuclear Power HPR1000
    Li, Feng
    Lu, Yazhe
    Chu, Xiao
    Zheng, Qiang
    Wu, Guanghao
    [J]. SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2021, 2021
  • [5] CFD investigation on start-up transient of HPR1000 secondary side passive residual heat removal heat exchanger
    Lang, Xutong
    Hou, Ting
    Zhang, Junming
    Guo, Yilong
    Guo, Zehua
    Ding, Ming
    [J]. ANNALS OF NUCLEAR ENERGY, 2024, 206
  • [6] HPR1000: Advanced Pressurized Water Reactor with Active and Passive Safety
    Xing, Ji
    Song, Daiyong
    Wu, Yuxiang
    [J]. ENGINEERING, 2016, 2 (01) : 79 - 87
  • [7] Analysis on containment thermal hydraulic behaviour under passive containment heat removal system operation condition for HPR1000
    Sun, Jing
    Wang, Hui
    Li, Jingjing
    [J]. International Journal of Advanced Nuclear Reactor Design and Technology, 2022, 4 (01): : 36 - 42
  • [8] AN INTEGRATED EXPERIMENTAL TEST FACILITY TO SUPPORT DEVELOPMENT OF THE PASSIVE CONTAINMENT COOLING SYSTEM OF HPR1000
    Li, Wei
    Du, Shuhong
    Gu, Weiquan
    Zhang, Nan
    Ding, Ming
    Sun, Zhongning
    Meng, Zhaoming
    [J]. PROCEEDINGS OF THE 2020 INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE2020), VOL 3, 2020,
  • [9] Research on Thermal Hydraulic Characteristic of HPR1000 Passive Containment Cooling System
    Ge, Kui
    Wang, Hui
    Wang, Mingjun
    Tian, Wenxi
    Su, Guanghui
    Qiu, Suizheng
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2021, 55 (05): : 769 - 777
  • [10] Design and transient analyses of emergency passive residual heat removal system of CPR1000
    Zhang, Y. P.
    Qiu, S. Z.
    Su, G. H.
    Tian, W. X.
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2012, 242 : 247 - 256