Design and transient analyses of emergency passive residual heat removal system of CPR1000

被引:33
|
作者
Zhang, Y. P. [1 ]
Qiu, S. Z. [1 ]
Su, G. H. [1 ]
Tian, W. X. [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Nucl Sci & Technol, Xian 710049, Peoples R China
关键词
SAFETY SYSTEMS;
D O I
10.1016/j.nucengdes.2011.09.036
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The steam generator secondary emergency passive residual heat removal system (EPRHRs) is a new design for traditional generation II + reactor CPR1000. The EPRHRs is designed to improve the safety and reliability of CPR1000 by completely or partially replacing traditional emergency water cooling system in the event of the station blackout or loss of heat sink accident. The EPRHRs consists of steam generator (SG), heat exchanger (HX), emergency makeup tank (EMT), cooling water tank (CWT), and corresponding pipes and valves. In order to improve the safety and reliability of CPR1000, the model of the primary loop and the EPRHRs was developed to investigate residual heat removal capability of the EPRHRs and the transient characteristics of the primary loop affected by the EPRHRs using RELAP5/MOD3.4. The transient characteristics of the primary loop and the EPRHRs were calculated in the event of station blackout accident. Sensitivity studies of the EPRHRs were also conducted to investigate the response of the primary loop and the EPRHRs on the main parameters of the EPRHRs. The EPRHRs could supply water to the SG shell side from the EMT successfully. The calculation results showed that the EPRHRs could take away the decay heat from the primary loop effectively, and that the single-phase and two-phase natural circulations were established in the primary loop and EPRHRs loop, respectively. The results also indicated that the effect of isolation valve open time on the transient characteristics of the primary loop was little. However, the effect of isolation valve open time on the EPRHRs condensate flow was relatively greater. The isolation valves should not be opened too rapidly during the isolation valve opening process, and the isolation valve opening time should be greater than 10 s, which could avoid the steam impact on the EPRHRs, and improve the stability of the system. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:247 / 256
页数:10
相关论文
共 50 条
  • [1] Design and transient analyses of emergency passive residual heat removal system of CPR1000. Part I: Air cooling condition
    Zhang, Yapei
    Qiu, Suizheng
    Su, Guanghui
    Tian, Wenxi
    [J]. PROGRESS IN NUCLEAR ENERGY, 2011, 53 (05) : 471 - 479
  • [2] Transient analysis of passive emergency feedwater system of CPR1000
    Zhang, Ya-Pei
    Tian, Wen-Xi
    Qiu, Sui-Zheng
    Su, Guang-Hui
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2011, 45 (10): : 1198 - 1202
  • [3] Research on the designed emergency passive residual heat removal system during the station blackout scenario for CPR1000
    Wang, Mingjun
    Zhao, Hao
    Zhang, Yapei
    Su, Guanghui
    Tian, Wenxi
    Qiu, Suizheng
    [J]. ANNALS OF NUCLEAR ENERGY, 2012, 45 : 86 - 93
  • [4] Transient analyses of passive residual heat removal system
    Zang, Xi'nian
    Huang, Bing
    Guo, Weijun
    [J]. 2000, Press of Tsinghua University (40):
  • [5] Transient analyses of the passive residual heat removal system
    Zang, XN
    Guo, WJ
    Huang, B
    Shen, SF
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2001, 206 (01) : 105 - 111
  • [6] Analysis of loss of residual heat removal system for CPR1000 under cold shutdown operation
    Gou, Junli
    Ma, Haifu
    Yang, Zijiang
    Shan, Jianqiang
    [J]. ANNALS OF NUCLEAR ENERGY, 2017, 105 : 25 - 35
  • [7] Analysis of SBLOCA on CPR1000 with a passive system
    Yang, Zi-Jiang
    Gou, Jun-Li
    Shan, Jian-Qiang
    Wu, Pan
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (01)
  • [8] Analysis of SBLOCA on CPR1000 with a passive system
    Zi-Jiang Yang
    Jun-Li Gou
    Jian-Qiang Shan
    Pan Wu
    [J]. Nuclear Science and Techniques, 2017, 28
  • [9] Analysis of SBLOCA on CPR1000 with a passive system
    Zi-Jiang Yang
    Jun-Li Gou
    Jian-Qiang Shan
    Pan Wu
    [J]. Nuclear Science and Techniques, 2017, 28 (01) : 92 - 101
  • [10] SGTR analysis on CPR1000 with a passive safety system
    Yang, Zijiang
    Shan, Jianqiang
    Gou, Junli
    Ishii, Mamoru
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2018, 332 : 319 - 328