Some technical, characteristics of magnetic fluids transducers for aerodynamic measurements

被引:3
|
作者
Popa, NC [1 ]
Siblini, A [1 ]
Jorat, L [1 ]
机构
[1] Acad Romana, Timisoara Branch, CAFTR, Timisoara 1900, Romania
来源
关键词
sensors; inductive transducers; magnetic fluids; aerodynamics; gas flow; numerical simulation;
D O I
10.1117/12.468260
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Inductive transducers with magnetic fluids (MF) for aerodynamic measurements have as essential components one or two pairs of identical electrical coils of circular cross section, uniformly wound. The carcasses of every pair of coils have the role of vertical cylindrical reservoir and communicate at the bottom creating a vertical U-shaped tube. At the equilibrium this tube is half filled with MF. The W has the role of a magnetic liquid core. This U system measure a pressure difference in gases at the top ends of the carcasses, this one is proportional to the difference between the inductances of the coils. For these transducers the paper presents the mechanical functioning principle, the detailed correction solution for inclination and acceleration, a theoretical electronic measuring system having only one element for zero adjustment and also some technical characteristics of these transducers obtained by a numerical simulation method.
引用
收藏
页码:149 / 159
页数:11
相关论文
共 50 条
  • [31] SOME MEASUREMENTS OF THE TIME DEPENDENCE OF THE VISCOSITY OF THIXOTROPIC FLUIDS
    BILLINGTON, EW
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1960, 75 (481): : 40 - 50
  • [32] THE AERODYNAMIC CHARACTERISTICS OF FURNACES BASED ON MODEL EXPERIMENTS AND HEAT MEASUREMENTS
    GUZOWSKI, J
    GUZOWSKI, J
    ENERGIETECHNIK, 1983, 33 (08): : 307 - 310
  • [33] In vitro measurements of aerodynamic characteristics of an improved tracheostoma valve for laryngectomees
    A. A. Geertsema
    M. P. de Vries
    H. K. Schutte
    J. Lubbers
    G. J. Verkerke
    European Archives of Oto-Rhino-Laryngology, 1998, 255 : 244 - 249
  • [34] SOME MEASUREMENTS OF THE ELASTIC AND VISCOUS PROPERTIES OF THIXOTROPIC FLUIDS
    BILLINGTON, EW
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1960, 76 (487): : 127 - 136
  • [35] In vitro measurements of aerodynamic characteristics of an improved tracheostoma valve for laryngectomees
    Geertsema, AA
    de Vries, MP
    Schutte, HK
    Lubbers, J
    Verkerke, GJ
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1998, 255 (05) : 244 - 249
  • [36] LONG-TERM STABILITY MEASUREMENTS ON MAGNETIC FLUIDS
    BISSELL, PR
    CHANTRELL, RW
    SPRATT, GWD
    BATES, PA
    OGRADY, KD
    IEEE TRANSACTIONS ON MAGNETICS, 1984, 20 (05) : 1738 - 1740
  • [37] MAGNETIC SUSPENSION DENSIMETER FOR MEASUREMENTS ON FLUIDS OF CRYOGENIC INTEREST
    HAYNES, WM
    HIZA, MJ
    FREDERICK, NV
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (10): : 1237 - 1250
  • [38] AC susceptibility measurements in the investigation of aggregation in magnetic fluids
    Fannin, PC
    Charles, SW
    ACTA PHYSICA POLONICA A, 2000, 97 (03) : 591 - 594
  • [39] Investigating magnetic fluids by means of complex susceptibility measurements
    Fannin, PC
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2003, 258 : 446 - 451
  • [40] High frequency ferromagnetic resonance measurements in magnetic fluids
    Fannin, PC
    Scaife, BKP
    Giannitsis, AT
    Mac Oireachtaigh, C
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 289 : 159 - 161