Capsule-Based dry powder inhaler evaluation using CFD-DEM simulations and next generation impactor data

被引:12
|
作者
Almeida, Lucilla C. [1 ]
Bharadwaj, Rahul [1 ]
Eliahu, Avi [2 ]
Wassgren, Carl R. [3 ]
Nagapudi, Karthik [4 ]
Muliadi, Ariel R. [4 ]
机构
[1] Engn Simulat & Sci Software, Rua Orlando Phillipi 100, BR-88032700 Florianopolis, SC, Brazil
[2] Genentech Inc, Device Dev, 1 DNA Way, South San Francisco, CA 94080 USA
[3] Purdue Univ, Sch Mech Engn, 585 Purdue Mall, W Lafayette, IN 47907 USA
[4] Genentech Inc, Small Mol Pharmaceut, Res & Early Dev gRED, 1 DNA Way, South San Francisco, CA 94080 USA
关键词
CFD-DEM; Dry powder inhalers; Discrete element method; Computational fluid dynamics; Inhalation drug delivery; COMPUTATIONAL FLUID-DYNAMICS; OROPHARYNGEAL DEPOSITION; PHARMACEUTICAL IMPACTOR; PARTICLE-SIZE; DEVICE DESIGN; PERFORMANCE; COMPARABILITY; FORMULATION; MODEL; FLOW;
D O I
10.1016/j.ejps.2022.106226
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Capsule-based, single-dose dry powder inhalers (DPIs) are commonly-used devices to deliver medications to the lungs. This work evaluates the effect of the drug/excipient adhesive bonding and the DPI resistances on the aerosol performance using a combination of empirical multi-stage impactor data and a fully-coupled computational fluid dynamics (CFD) and discrete element method (DEM) model. Model-predicted quantities show that the primary modes of powder dispersion are a function of the device resistance. Lowering the device resistance increases its capacity to transport a wider range of particle size classes toward the outlet and generate more intense turbulence upstream therein. On the other hand, a higher device resistance increases the velocity of the tangential airflow along the device walls, which in turn increases the intensity of particle/device impaction. Correlating model data and experimental results shows that these differing powder dispersion mechanisms affect different formulations differently, with finer aerosols tending to result when pairing a lower resistance device with formulations that exhibit low API/excipient adhesion, or when pairing a high resistance device with more cohesive formulations.
引用
收藏
页数:19
相关论文
共 27 条
  • [21] CFD-DEM simulations of a continuous square-based spouted bed and evaluation of the solids residence time distribution
    Marchelli, Filippo
    Moliner, Cristina
    Curti, Massimo
    Bosio, Barbara
    Arato, Elisabetta
    POWDER TECHNOLOGY, 2020, 366 : 840 - 858
  • [22] Assessment of the efficacy and safety of fluticasone propionate and salmeterol delivered as a combination dry powder via a capsule-based inhaler versus a multi-dose inhaler in patients with chronic obstructive pulmonary disease
    Chan, Robert
    Sousa, Ana R.
    Hynds, Peter
    Homayoun-Valiani, Farshid
    Edwards, Dawn
    Tabberer, Maggie
    PULMONARY PHARMACOLOGY & THERAPEUTICS, 2017, 43 : 12 - 19
  • [23] Comparative Evaluation of Fine Particle Fraction and T2 Fraction by Using Next Generation Impactor (NGI) and Glass Twin Impinger (GTI) on Formoterol Fumarate and Tiotropium Dry Powder Inhaler (DPI) Marketed Products
    P. S. Gondhale
    M. J. Deshmukh
    R. V. Omase
    A. N. Arbune
    P. Kolsure
    S. G. Bhope
    S. Padmanabhan
    Pharmaceutical Chemistry Journal, 2022, 56 : 720 - 726
  • [24] Comparative Evaluation of Fine Particle Fraction and T2 Fraction by Using Next Generation Impactor (NGI) and Glass Twin Impinger (GTI) on Formoterol Fumarate and Tiotropium Dry Powder Inhaler (DPI) Marketed Products
    Gondhale, P. S.
    Deshmukh, M. J.
    Omase, R., V
    Arbune, A. N.
    Kolsure, P.
    Bhope, S. G.
    Padmanabhan, S.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2022, 56 (05) : 720 - 726
  • [25] Effect of Sampling Volume on Dry Powder Inhaler (DPI)-Emitted Aerosol Aerodynamic Particle Size Distributions (APSDs) Measured by the Next-Generation Pharmaceutical Impactor (NGI) and the Andersen Eight-Stage Cascade Impactor (ACI)
    Hlack Mohammed
    Daryl L. Roberts
    Mark Copley
    Mark Hammond
    Steven C. Nichols
    Jolyon P. Mitchell
    AAPS PharmSciTech, 2012, 13 : 875 - 882
  • [26] Effect of Sampling Volume on Dry Powder Inhaler (DPI)-Emitted Aerosol Aerodynamic Particle Size Distributions (APSDs) Measured by the Next-Generation Pharmaceutical Impactor (NGI) and the Andersen Eight-Stage Cascade Impactor (ACI)
    Mohammed, Hlack
    Roberts, Daryl L.
    Copley, Mark
    Hammond, Mark
    Nichols, Steven C.
    Mitchell, Jolyon P.
    AAPS PHARMSCITECH, 2012, 13 (03): : 875 - 882
  • [27] Evaluation of DEM generation based on Interferometric SAR using TanDEM-X data in Tokyo
    Avtar, Ram
    Yunus, Ali P.
    Kraines, Steven
    Yamamuro, Masumi
    PHYSICS AND CHEMISTRY OF THE EARTH, 2015, 83-84 : 166 - 177