Cellulose I crystallinity determination using FT-Raman spectroscopy: univariate and multivariate methods

被引:230
|
作者
Agarwal, Umesh P. [1 ]
Reiner, Richard S. [1 ]
Ralph, Sally A. [1 ]
机构
[1] US Forest Serv, Forest Prod Lab, USDA, Madison, WI 53705 USA
关键词
Cellulose; Crystallinity; Raman spectroscopy; FT-Raman; Univariate; Multivariate; PLS; X-ray; X-RAY-DIFFRACTION; WOOD; NMR; SPECTRA; TRANSMISSION; FIBERS; POWDER; SIZE;
D O I
10.1007/s10570-010-9420-z
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
Two new methods based on FT-Raman spectroscopy, one simple, based on band intensity ratio, and the other using a partial least squares (PLS) regression model, are proposed to determine cellulose I crystallinity. In the simple method, crystallinity in cellulose I samples was determined based on univariate regression that was first developed using the Raman band intensity ratio of the 380 and 1,096 cm(-1) bands. For calibration purposes, 80.5% crystalline and 120-min milled (0% crystalline) Whatman CC31 and six cellulose mixtures produced with crystallinities in the range 10.9-64% were used. When intensity ratios were plotted against crystallinities of the calibration set samples, the plot showed a linear correlation (coefficient of determination R (2) = 0.992). Average standard error calculated from replicate Raman acquisitions indicated that the cellulose Raman crystallinity model was reliable. Crystallinities of the cellulose mixtures samples were also calculated from X-ray diffractograms using the amorphous contribution subtraction (Segal) method and it was found that the Raman model was better. Additionally, using both Raman and X-ray techniques, sample crystallinities were determined from partially crystalline cellulose samples that were generated by grinding Whatman CC31 in a vibratory mill. The two techniques showed significant differences. In the second approach, successful Raman PLS regression models for crystallinity, covering the 0-80.5% range, were generated from the ten calibration set Raman spectra. Both univariate-Raman and WAXS determined crystallinities were used as references. The calibration models had strong relationships between determined and predicted crystallinity values (R (2) = 0.998 and 0.984, for univariate-Raman and WAXS referenced models, respectively). Compared to WAXS, univariate-Raman referenced model was found to be better (root mean square error of calibration (RMSEC) and root mean square error of prediction (RMSEP) values of 6.1 and 7.9% vs. 1.8 and 3.3%, respectively). It was concluded that either of the two Raman methods could be used for cellulose I crystallinity determination in cellulose samples.
引用
收藏
页码:721 / 733
页数:13
相关论文
共 50 条
  • [21] Classification of Frankfurters by FT-Raman Spectroscopy and Chemometric Methods
    Campos, Naira da Silva
    Oliveira, Kamila de Sa
    Almeida, Mariana Ramos
    Stephani, Rodrigo
    Cappa de Oliveira, Luiz Fernando
    MOLECULES, 2014, 19 (11) : 18980 - 18992
  • [22] Biomolecular investigations using FT-Raman spectroscopy
    Bhandare, PS
    Jakobsen, R
    Krishnan, K
    MIKROCHIMICA ACTA, 1997, : 739 - 740
  • [23] PALAEODENTAL STUDIES USING FT-RAMAN SPECTROSCOPY
    EDWARDS, HGM
    WILLIAMS, AC
    FARWELL, DW
    BIOSPECTROSCOPY, 1995, 1 (01): : 29 - 36
  • [24] Determination of wood properties by FT-Raman spectroscopy in Eucalyptus
    Ona, T
    Sonoda, T
    Ohshima, Y
    Yokota, S
    Yoshizawa, N
    55TH APPITA ANNUAL CONFERENCE, PROCEEDINGS, 2001, : 45 - 49
  • [25] Characterisation of biomaterials using FT-Raman spectroscopy
    Soderholm, S
    Roos, YH
    Meinander, N
    Hotokka, M
    FOURIER TRANSFORM SPECTROSCOPY, 1998, (430): : 316 - 319
  • [26] OPTIMIZATION IN FT-RAMAN SPECTROSCOPY
    CHASE, DB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 42 - POLY
  • [27] ARTIFACTS IN FT-RAMAN SPECTROSCOPY
    CHASE, DB
    7TH INTERNATIONAL CONFERENCE ON FOURIER TRANSFORM SPECTROSCOPY, 1989, 1145 : 172 - 173
  • [28] Transformations of wood-cellulose ultrastructure: Investigations of molecular-conformation, extent of disorder, and crystallinity by FT-Raman spectroscopy
    Agarwal, Umesh
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [29] Neutral geopolymer foams reinforced with cellulose studied with the FT-Raman spectroscopy
    Szechynska-Hebda, M.
    Marczyk, J.
    Ziejewska, C.
    Hordynska, N.
    Mikula, J.
    Hebda, M.
    DEVELOPMENT OF ECO-FRIENDLY COMPOSITE MATERIALS BASED ON GEOPOLYMER MATRIX AND REINFORCED WITH WASTE FIBERS, 2019, 706
  • [30] Quantitative determination of captopril and prednisolone in tablets by FT-Raman spectroscopy
    Mazurek, S
    Szostak, R
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (05) : 1225 - 1230