Potentiometric determination of pantoprazole using an ion-selective sensor based on polypyrrole doped films

被引:11
|
作者
Noronha, Barbara V. [1 ]
Bindewald, Eduardo H. [1 ]
de Oliveira, Michelle C. [1 ]
Papi, Mauricio A. P. [1 ]
Bergamini, Marcio F. [1 ]
Marcolino-, Luiz H., Jr. [1 ]
机构
[1] Univ Fed Parana UFPR, Dept Quim, Lab Sensores Eletroquim LabSensE, BR-81531980 Curitiba, PR, Brazil
关键词
Pantoprazole determination; Disposable potentiometric sensor; Polypyrrole doped film; Low cost analysis; CARBON ELECTRODE; NANOPARTICLES; OXIDE;
D O I
10.1016/j.msec.2014.07.060
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The present work reports for the first time the use of polypyrrole (PPy) doped film for development of a potentiometric disposable sensor for determination of pantoprazole (PTZ), a drug used for ulcer treatment. Selective potentiometric response has been found by using a membrane of PPy doped with PTZ anions prepared under galvanostatic conditions at graphite pencil electrode (GPEM/PPy-PTZ) surface. Potentiometric response has been influenced for conditions adopted in polymerization and measurement step. After optimization of experimental (e.g. pH and time of conditioning) and instrumental parameters (e.g. current density and electrical charge) a linear analytical curve from 1.0 x 10(-5) to 1.1 x 10(-2) mol L-1 with a slope of calibration of the 57.6 mV dec(-1) and limit of detection (LOD) of 6.9 x 10(-6) mol L-1 was obtained. The determination of the PTZ content in pharmaceutical samples using the proposed methodology and official method recommended by Brazilian Pharmacopeia are in agreement at the 95% confidence level and within an acceptable range of error. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:517 / 520
页数:4
相关论文
共 50 条
  • [1] Determination of lactate levels in biological fluids using a disposable ion-selective potentiometric sensor based on polypyrrole films
    Mengarda, Priscilla
    Dias, Fernando A. L.
    Peixoto, Joao V. C.
    Osiecki, Raul
    Bergamini, Marcio F.
    Marcolino-Junior, Luiz H.
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 296
  • [2] Potentiometric determination of Diclofenac using an ion-selective electrode prepared from polypyrrole films
    Oliveira, Michelle C.
    Bindewald, Eduardo H.
    Marcolino, Luiz H., Jr.
    Bergamini, Marcio F.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 732 : 11 - 16
  • [3] Nitrate ion-selective sensor based on electrochemically prepared conducting polypyrrole films
    Sun, BT
    Fitch, PG
    ELECTROANALYSIS, 1997, 9 (06) : 494 - 497
  • [4] An ion-selective potentiometric sensor for hexafluoroarsenate
    A. V. Kopytin
    A. F. Zhukov
    E. G. Il’in
    Journal of Analytical Chemistry, 2015, 70 : 485 - 487
  • [5] An ion-selective potentiometric sensor for hexafluoroarsenate
    Kopytin, A. V.
    Zhukov, A. F.
    Il'in, E. G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (04) : 485 - 487
  • [6] POTENTIOMETRIC DETERMINATION OF SULFATE-ION WITH USING OF ION-SELECTIVE ELECTRODES
    KONDRATENKO, LA
    LYUBINA, VA
    IZVESTIYA SIBIRSKOGO OTDELENIYA AKADEMII NAUK SSSR SERIYA KHIMICHESKIKH NAUK, 1989, (01): : 91 - 97
  • [7] POTENTIOMETRIC DETERMINATION OF GOLD IN ELECTROLYTES USING ION-SELECTIVE ELECTRODES
    BOROVSKII, ES
    RAKHMANKO, EM
    STAROBINETS, GL
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1985, 40 (08): : 1127 - 1130
  • [8] POTENTIOMETRIC DETERMINATION OF IODIPAMIDE USING AN IODIPAMIDE ION-SELECTIVE ELECTRODE
    YAO, SZ
    LIU, DZ
    NIE, LH
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (04) : 373 - 377
  • [9] Ion-selective potentiometric determination of lead in minerals
    Vlasov, YG
    Ermolenko, YE
    Kolodnikov, VV
    Murzina, YG
    JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 54 (11) : 1056 - 1062
  • [10] POTENTIOMETRIC DETERMINATION OF PENICILLINS WITH ION-SELECTIVE ELECTRODES
    YAO, SZ
    SHIAO, J
    NIE, LH
    TALANTA, 1989, 36 (12) : 1249 - 1252