Evaluation of the photon dose calculation accuracy in radiation therapy of malignant pleural mesothelioma

被引:5
|
作者
Mahmoudi, Golshan [1 ,2 ]
Farhood, Bagher [2 ]
Shokrani, Parvaneh [3 ]
Amouheidari, Alireza [4 ]
Atarod, Maryam [5 ]
机构
[1] Sabzevar Univ Med Sci, Dept Med Phys, Sabzevar, Iran
[2] Univ Tehran Med Sci, Sch Med, Dept Med Phys & Biomed Engn, Tehran, Iran
[3] Isfahan Univ Med Sci, Sch Med, Dept Med Phys, Esfahan, Iran
[4] Milad Hosp, Dept Radiat Oncol, Esfahan, Iran
[5] Shahrekord Univ Med Sci, Sch Med, Dept Med Phys, Shahrekord, Iran
关键词
EGSnrc Monte Carlo code; inhomogeneity; malignant pleural mesothelioma; radiation therapy; TiGRT; EXTERNAL-BEAM RADIOTHERAPY; TREATMENT PLANNING SYSTEMS; MONTE-CARLO; AIR CAVITIES; 6; MV; LUNG; EQUILIBRIUM; ALGORITHMS; SIMULATION; MEDIA;
D O I
10.4103/0973-1482.187284
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Photon dose distribution of malignant pleural mesothelioma (MPM) in matched photon-electron technique is influenced by media inhomogeneity, lateral electronic disequilibrium at interfaces and narrow field. These may influence the dose calculation accuracy, calculated by treatment planning systems (TPS). This study aimed to evaluate the dose calculation accuracy of TiGRT TPS in radiation therapy of MPM. Materials and Methods: 18 MV photon beams of ONCOR Siemens linear accelerator was simulated using EGSnrc Monte Carlo (MC) code. Data of four patients were used to compare TPS and MC results in different regions included: Open and in-field, under shied and out of field regions. Results: Compared to MC results, the TPS overestimated the pleura dose coverage (90% of prescribed dose) about 3-12 mm, and also it overestimated the dose in under the shielded regions of lung (4-74%). While the TPS underestimated the dose profile width about 1-16 mm in low dose region (<50% prescribed dose) as well as the out of field region dose (4-100%). Conclusions: Results showed that TPS underestimated the dose in out of field and overestimated the dose in under the shielded regions. Unlike MC measurements, TPS calculation showed adequate pleural dose coverage. Based on the results, MC calculation can be used in matched photon-electron beam radiation therapy of MPM to modify the TPS photon dose calculations in the presence of heterogeneity, interfaces, and shield in MPM radiotherapy.
引用
收藏
页码:1029 / 1035
页数:7
相关论文
共 50 条
  • [41] Current Readings: Improvements in Intensity Modulated Radiation Therapy for Malignant Pleural Mesothelioma
    Rosenzweig, Kenneth E.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2013, 25 (03) : 245 - 250
  • [42] A reply to "managing oligoprogressive malignant pleural mesothelioma with stereotactic body radiation therapy"
    Ceresoli, Giovanni L.
    Ghirardelli, Paolo
    Franceschini, Davide
    Scorsetti, Marta
    Vavassori, Vittorio
    LUNG CANCER, 2021, 157 : 165 - 166
  • [43] MALIGNANT PLEURAL MESOTHELIOMA - COMBINED ADRIAMYCIN AND RADIATION-THERAPY - A FEASIBILITY STUDY
    SINOFF, C
    FALKSON, G
    SANDISON, AG
    DEMUELENAERE, G
    PROCEEDINGS OF THE AMERICAN ASSOCIATION FOR CANCER RESEARCH, 1981, 22 (MAR): : 524 - 524
  • [44] Pleural resection and pleural infusion chemotherapy for therapy of malignant pleural mesothelioma
    Zhang, J.
    Zhang, Q.
    Zhao, W.
    Duan, J.
    Huang, T.
    GENETICS AND MOLECULAR RESEARCH, 2014, 13 (01) : 483 - 489
  • [45] Accuracy Assessment of Photon-Counting CT for Dose Calculation in Photon Therapy
    Wu, X.
    Shah, J.
    Wohlfahrt, P.
    Wu, Q.
    Wu, Q. J.
    Sheng, Y.
    MEDICAL PHYSICS, 2024, 51 (10) : 7669 - 7669
  • [46] Advances in the systemic therapy of malignant pleural mesothelioma
    Fennell, Dean A.
    Gaudino, Giovanni
    O'Byrne, Kenneth J.
    Mutti, Luciano
    van Meerbeeck, Jan
    NATURE CLINICAL PRACTICE ONCOLOGY, 2008, 5 (03): : 136 - 147
  • [47] Advances in the systemic therapy of malignant pleural mesothelioma
    Dean A Fennell
    Giovanni Gaudino
    Kenneth J O'Byrne
    Luciano Mutti
    Jan van Meerbeeck
    Nature Clinical Practice Oncology, 2008, 5 : 136 - 147
  • [48] Systemic Therapy of Inoperable Malignant Pleural Mesothelioma
    Scherpereel, Arnaud
    JOURNAL OF THORACIC ONCOLOGY, 2017, 12 (01) : S60 - S61
  • [49] Radical multimodality therapy for malignant pleural mesothelioma
    Abdel-Rahman, Omar
    Elsayed, Zeinab
    Mohamed, Hadeer
    Eltobgy, Mostafa
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2018, (01): : CD012605
  • [50] Trimodality therapy in the treatment of malignant pleural mesothelioma
    Castagnelo, B
    Manzin, E
    Zai, S
    Casadio, C
    Maggi, G
    Rovea, P
    Ozzello, F
    Botta, M
    Brelli, S
    ANNALS OF ONCOLOGY, 2000, 11 : 2 - 2