Development non-contact gripper with flowrate-amplification using Coanda ejector

被引:4
|
作者
Liu, Hanbang [1 ,2 ]
Li, Xinrong [1 ,2 ]
Ma, Qianli [3 ]
Feng, Wenqian [1 ,2 ]
机构
[1] Tiangong Univ, Sch Mech Engn, Tianjin 300387, Peoples R China
[2] Key Lab Modern Mech & Elect Equipment Technol, Tianjin 300387, Peoples R China
[3] Henan Haochang Combing Machine Joint Stock Ltd Co, Kaifeng 475000, Henan, Peoples R China
基金
国家重点研发计划;
关键词
Coanda effect; Non-contact gripping; Energy saving; Lifting force; BERNOULLI-PRINCIPLE; END-EFFECTOR; OBJECTS; PUMP;
D O I
10.1016/j.vacuum.2021.110108
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The energy-saving mechanism for the gas consumption of a non-contact gripper with flowrate-amplification using Coanda ejector is proposed to solve the problems of excessive power consumption and an insufficient lifting force in non-contact grippers. The mechanism of the proposed non-contact gripper is derived using pressure differences to generate the lifting force, and the energy-saving principle is described in detail. The effects of the supply gas flow rate and the gap height on the adsorption capacity of the non-contact gripper are studied experimentally. Finally, comparing the proposed non-contact gripper with traditional approaches indicates that the lifting force is 15-20% higher under the same supply gas flow rate. This research provides new ideas for research on non-contact grippers and provides theoretical support for their design.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A non-contact ammeter using phosphor thermometry
    Shope, DA
    Mahajan, SM
    PROCEEDINGS OF THE THIRTY-FOURTH SOUTHEASTERN SYMPOSIUM ON SYSTEM THEORY, 2002, : 184 - 187
  • [32] Development of new calibration standard for non-contact tonometers
    Pavlasek, Peter
    Chytil, Miroslav
    Rybar, Jan
    Palencar, Jakub
    Duris, Stanislav
    Pavlasek, Peter
    2018 11TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2018), 2018,
  • [33] THE DEVELOPMENT OF NON-CONTACT 'TOUCHLESS' MONITORING OF RESPIRATORY RATE
    Addison, Paul S.
    Antunes, Andre
    Montgomery, Dean
    ANESTHESIA AND ANALGESIA, 2022, 134 (4S_SUPPL): : 62 - 63
  • [34] Development of a Non-contact Jet Dispensing of Liquid Metals
    Maslik, Jan
    Martensson, Gustaf
    Gumiero, Alessandro
    Cometti, Elio
    Hjort, Klas
    2024 IMAPS NORDIC CONFERENCE ON MICROELECTRONICS PACKAGING, NORDPAC 2024, 2024,
  • [35] Development of a non-contact sleep monitoring system for children
    Kamon, Masamitsu
    Okada, Shima
    Furuta, Masafumi
    Yoshida, Koki
    FRONTIERS IN DIGITAL HEALTH, 2022, 4
  • [36] Development of Non-Contact Measurement System of Human Stepping
    Kurita, Koichi
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 1031 - 1034
  • [37] THE DESIGN AND DEVELOPMENT OF A NON-CONTACT PRINTER FOR PRODUCT CODING
    KING, D
    LUK, R
    MASSINGBERDMUNDY, P
    SENDELL, A
    HOLMES, R
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 1988, 202 (02) : 87 - 92
  • [38] Thermal isolation of microchip reaction chambers for rapid non-contact DNA amplification
    Easley, Christopher J.
    Humphrey, Joseph A. C.
    Landers, James P.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2007, 17 (09) : 1758 - 1766
  • [39] Composite Evaluation Using Contact and Non-contact Ultrasound Excited Thermography
    Feng Lichun
    Chen Dapeng
    Zeng Zhi
    Tao Ning
    MATERIALS, MECHANICAL ENGINEERING AND MANUFACTURE, PTS 1-3, 2013, 268-270 : 1627 - +