Seismic response and damage limit of concrete filled steel tube frame

被引:0
|
作者
Goto, K. [1 ]
机构
[1] Miyakonojo Natl Coll Technol, Miyazaki, Japan
来源
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismic response and damage of Concrete Filled steel Tube frame (CFT frame) under strong ground motion are calculated. The damage ratios of cracking and local buckling of CFT column and H-section beam, which are closely related to the collapse of CFT frame, are obtained in relation with the column-over-design factor and the strength ratio of CFT column. On the basis of the calculated results, the damage limits of CFT frame are investigated to prevent the local buckling and steel tube cracking of CFT column in relation with the ultimate state design conditions which are the column-over-design factor of CFT frame, the strength ratio of CFT column and the maximum velocity of input ground motion.
引用
收藏
页码:533 / 539
页数:7
相关论文
共 50 条
  • [41] Seismic Performance of Concrete-Filled Steel Tube to Concrete Pile-Cap Connections
    Kappes, Lenci
    Berry, Michael
    Murray, Flynn
    Stephens, Jerry
    Barnes, Kent
    JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (07)
  • [42] Seismic Damage Evaluation of Concrete-Encased Steel Frame-Reinforced Concrete Core Tube Buildings Based on Dynamic Characteristics
    Zeng, Lei
    Xiao, Yunfeng
    Chen, Yiguang
    Jin, Siqian
    Xie, Wei
    Li, Xianjie
    APPLIED SCIENCES-BASEL, 2017, 7 (04):
  • [43] Experimental Investigation on the Seismic Performance of Novel Prefabricated Composite RC Shear Walls with Concrete-Filled Steel Tube Frame
    Dou, Lijun
    Huang, Ziheng
    Liu, Yuxi
    Wang, Yuhao
    Zhao, Lei
    BUILDINGS, 2024, 14 (09)
  • [44] A study on the seismic performance of concrete-filled steel tube column-steel shelf-concrete core tube structures
    Zeng F.
    Huang Y.
    Zhou J.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2020, 39 (12): : 190 - 197
  • [45] Analysis on design parameters of seismic performance based on damage for recycled aggregate concrete-filled steel tube column
    Zhang, Xianggang
    Deng, Dapeng
    Yang, Jianhui
    INTERNATIONAL JOURNAL OF STRUCTURAL INTEGRITY, 2020, 11 (02) : 185 - 201
  • [46] Experimental study on the seismic damage behavior of composite joints of concrete-filled steel tube column with blind bolts
    Liu, Huanhuan
    Yan, Shilin
    Wang, Xinwu
    Zhang, Jianke
    Lin, Yongle
    STRUCTURES, 2024, 70
  • [47] Analysis of the seismic response and vulnerability of square stirrup-confined concrete-filled steel tube columns
    Ding, Faxing
    Luo, Shijia
    Sadat, Said Ikram
    Sun, Hao
    Lyu, Fei
    ENGINEERING STRUCTURES, 2025, 333
  • [48] Seismic performance of concrete filled steel tubular frame with integral assembled infilled wall
    Zhou Z.
    Xu Z.
    Tian L.
    Wang T.
    Li Y.
    Feng A.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2021, 53 (04): : 89 - 95
  • [49] Research on seismic performance of prefabricated concrete-filled steel tubular frame joints
    Li, Shufeng
    Zhao, Di
    Zhou, Yating
    INTERNATIONAL JOURNAL OF STRUCTURAL INTEGRITY, 2022, 13 (02) : 327 - 347
  • [50] Evaluation of Damage Indices for Rectangular Concrete-filled Steel Tube Structures
    Guan, Minsheng
    Lin, Siying
    Du, Hongbiao
    Cui, Jie
    Yan, Taizhou
    MEASUREMENT SCIENCE REVIEW, 2019, 19 (04): : 170 - 184