Lumen enhancement and flow estimation by temporal correlation of radio frequency intravascular ultrasound

被引:0
|
作者
Li, W [1 ]
van der Steen, AFW [1 ]
Lancee, CT [1 ]
Gussenhoven, EJ [1 ]
Bom, N [1 ]
机构
[1] Erasmus Univ, Thoraxctr, NL-3000 DR Rotterdam, Netherlands
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study was designed to investigate the time-varying characteristics of blood scattering on high frequency intravascular ultrasound in vivo from pig experiments. Results show that blood scattering signals de-correlate significantly faster than signals received from arterial tissues. A correlation method based on this characteristic has been developed to suppress the blood echo intensity. Preliminary investigation also indicates that flow information can be extracted from the relationship between the temporal correlation and the flow velocity.
引用
收藏
页码:867 / 868
页数:2
相关论文
共 50 条
  • [21] Discrepant findings of computed tomography quantification of minimal lumen area of coronary artery stenosis: Correlation with intravascular ultrasound
    Li, Yuehua
    Zhang, Jiayin
    Lu, Zhigang
    Pan, Jingwei
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3270 - 3275
  • [22] Automated quantitation of non-steady flow and lumen area based on temporal correlation
    Lee, SH
    Alperin, N
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 2613 - 2616
  • [23] Automated quantitation of non-steady flow and lumen area using temporal correlation
    Lee, SH
    Alperin, N
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 593 - 596
  • [24] Estimation methods flow imaging with high frequency ultrasound
    Aoudi, W.
    Liebgott, H.
    Needles, A.
    Yang, V.
    Foster, F. S.
    Vray, D.
    ULTRASONICS, 2006, 44 (e135-e140) : E135 - E140
  • [25] Quantitative blood flow estimation error due to the in-plane component of the flow with intravascular ultrasound
    de Ana, FJ
    O'Donnell, M
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 580 - 583
  • [26] Quantitative blood flow estimation error due to the in-plane component of the flow with intravascular ultrasound
    de Ana, FJ
    O'Donnell, M
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 851 - 854
  • [27] Good correlation between minimal lumen area by 3D reconstruction coronary angiography and intravascular ultrasound.
    Sagara, S.
    Sadamatsu, K.
    Nagaoka, K.
    Shikada, T.
    Ooe, K.
    Morishige, K.
    Tanaka, E.
    Yamawaki, T.
    Tashiro, H.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (8B): : 42C - 42C
  • [28] Enhancement of cascaded frequency upconversion by ultrafast temporal correlation of twin beams
    Eto, Yujiro
    OPTICS LETTERS, 2024, 49 (12) : 3344 - 3347
  • [29] Towards Extra-Luminal Blood Detection from Intravascular Ultrasound Radio Frequency Data
    Mendizabal-Ruiz, E. Gerardo
    Biros, George
    Kakadiaris, Ioannis A.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 396 - +
  • [30] RADIO FREQUENCY SIGNAL ANALYSIS FOR TISSUE CHARACTERIZATION OF CORONARY ARTERY: IN VIVO INTRAVASCULAR ULTRASOUND STUDY
    Iwamoto, T.
    Saijo, Y.
    Tanaka, A.
    Filho, E. S.
    Li, S.
    Yoshizawa, M.
    ACOUSTICAL IMAGING, VOL 29, 2008, 29 : 147 - +