Investigation of dielectric breakdown probability distribution for vacuum disconnecting switch

被引:0
|
作者
Shioiri, T
Sasage, K
Toru, K
Homma, M
Kaneko, E
机构
关键词
vacuum insulation; vacuum disconnecting switch; Weibull plot; breakdown probability distribution; no-load switching;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Vacuum insulation system has little effect on environments. Therefore, vacuum insulation system is expected to find wider application, such as disconnecting switch and earthing switch. To investigate the reliability of equipment of vacuum insulation, a study was carried out to clarify breakdown probability distributions in vacuum gap. Experiments were carried out to compare a uniform field gap and non-uniform field gap on the breakdown probability distributions. Further, experiments were carried out to investigate effects of no-load switching on the breakdown probability distributions for vacuum disconnecting switch. The electrode materials were oxygen-free copper and copper-chromium alloy. The test results show that the breakdown probability distribution of the vacuum gap can be represented by a Weibull distribution using a location parameter, which show the voltage that permits a zero breakdown probability. When aiming for highly reliable vacuum disconnecting switch, an important factor is insulation design with the location parameter just mentioned take into account. The location parameter obtained Weibull plot depends on electrode area. This is probably because the existence probability of factors as weak-points for breakdowns such as micro-protrusions and microparticles depends on the electrode area. The shape parameter obtained Weibull plot of vacuum gap was 1013, and is constant irrespective non-uniform field factor. The breakdown probability distribution after no-load switching can be represented by Weibull distribution using a location parameter. The shape parameter after no-load switching was 6similar to8.5, and is constant, irrespective of gap length. This indicates that the scatter of breakdown voltage was increased by no-load switching. It is supposed that the cause of this phenomena is generation of microparticles and field emission site on the surface of copper-chromium contacts.
引用
收藏
页码:1780 / 1785
页数:6
相关论文
共 50 条
  • [21] Dielectric breakdown probabilities for uniform field gap in vacuum
    Shioiri, T
    Kamikawaji, T
    Yokokura, K
    Kaneko, E
    Ohshima, I
    Yanabu, S
    ISDEIV: XIXTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, VOLS 1 AND 2, PROCEEDINGS, 2000, 19 : 17 - 20
  • [22] Investigation of charge distribution on the dielectric envelope of high-voltage vacuum tube
    Bochkov, VD
    Pogorelsky, MM
    ISDEIV - XVIITH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, PROCEEDINGS, VOLS I AND II, 1996, : 415 - 419
  • [23] Prediction Method of the Breakdown Probability for Multiple Vacuum Gaps in Series Considering Dielectric Recovery Under a Lightning Impulse Voltage
    Ma, Hui
    Shen, Jingyu
    Ding, Jian'gang
    Chi, Dianyu
    Liu, Zhiyuan
    Geng, Yingsan
    Wang, Jianhua
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2022, 29 (02) : 753 - 761
  • [24] INVESTIGATION OF A SUPER-HIGH VACUUM BREAKDOWN
    PROSKUROVSKII, DI
    PUCHKAREV, VF
    CHESNOKOV, SM
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII FIZIKA, 1974, (07): : 136 - 138
  • [25] INVESTIGATION OF HIGH-VACUUM ELECTRICAL BREAKDOWN
    TARASOVA, LV
    KALININ, VG
    SOVIET PHYSICS-TECHNICAL PHYSICS, 1964, 9 (04): : 514 - +
  • [26] Investigation of Vacuum Breakdown in Pulsed DC Systems
    Kaufmann, Helena T. C.
    Profatilova, Iaroslava
    Popov, Inna
    Wuensch, Walter
    Benilov, Mikhail S.
    29TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2020), 2021, : 19 - 22
  • [27] Investigation and Optimization of Magnetron Discharge in a Vacuum Switch
    Godechot, X.
    Nicolle, C.
    Hairour, M.
    Olive, S.
    Picot, P.
    25TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2012), 2012, : 465 - 468
  • [28] Lifetime Investigation of Vacuum Surface Flashover Switch
    Zeng, B.
    Su, J. C.
    Zhang, X. B.
    Cheng, J.
    Wu, X. L.
    Fang, J. P.
    Wang, L. M.
    Sun, X.
    Zhao, L.
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 460 - 463
  • [29] Initial Plasma Development of Field-Breakdown Triggered Vacuum Switch
    Zhou, Zhengyang
    Liao, Minfu
    Zou, Jiyan
    Lin, Fuchang
    Zhang, Li
    Li, Hua
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2011, 39 (01) : 360 - 363
  • [30] Switching-on experiment of a field-breakdown triggered vacuum switch
    Zhou, Zheng-Yang
    Liao, Min-Fu
    Zou, Ji-Yan
    Lin, Fu-Chang
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (12): : 3059 - 3064