Investigation of dielectric breakdown probability distribution for vacuum disconnecting switch

被引:0
|
作者
Shioiri, T
Sasage, K
Toru, K
Homma, M
Kaneko, E
机构
关键词
vacuum insulation; vacuum disconnecting switch; Weibull plot; breakdown probability distribution; no-load switching;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Vacuum insulation system has little effect on environments. Therefore, vacuum insulation system is expected to find wider application, such as disconnecting switch and earthing switch. To investigate the reliability of equipment of vacuum insulation, a study was carried out to clarify breakdown probability distributions in vacuum gap. Experiments were carried out to compare a uniform field gap and non-uniform field gap on the breakdown probability distributions. Further, experiments were carried out to investigate effects of no-load switching on the breakdown probability distributions for vacuum disconnecting switch. The electrode materials were oxygen-free copper and copper-chromium alloy. The test results show that the breakdown probability distribution of the vacuum gap can be represented by a Weibull distribution using a location parameter, which show the voltage that permits a zero breakdown probability. When aiming for highly reliable vacuum disconnecting switch, an important factor is insulation design with the location parameter just mentioned take into account. The location parameter obtained Weibull plot depends on electrode area. This is probably because the existence probability of factors as weak-points for breakdowns such as micro-protrusions and microparticles depends on the electrode area. The shape parameter obtained Weibull plot of vacuum gap was 1013, and is constant irrespective non-uniform field factor. The breakdown probability distribution after no-load switching can be represented by Weibull distribution using a location parameter. The shape parameter after no-load switching was 6similar to8.5, and is constant, irrespective of gap length. This indicates that the scatter of breakdown voltage was increased by no-load switching. It is supposed that the cause of this phenomena is generation of microparticles and field emission site on the surface of copper-chromium contacts.
引用
收藏
页码:1780 / 1785
页数:6
相关论文
共 50 条
  • [1] Investigation of dielectric breakdown characteristics for double-break vacuum interrupter and dielectric breakdown probability distribution in vacuum interrupter
    Toshiba Corporation, 1, Toshiba-cho, Fuchu 183-8511, Japan
    IEEJ Trans. Power Energy, 2008, 12 (1452-1458+4):
  • [2] Investigation of Dielectric Breakdown Characteristics of Double-Break Vacuum Interrupter and Dielectric Breakdown Probability Distribution in Vacuum Interrupter
    Shioiri, Tetsu
    Asari, Naoki
    Sato, Junichi
    Sasage, Kosuke
    Yokokura, Kunio
    Homma, Mitsutaka
    Suzuki, Katsumi
    ELECTRICAL ENGINEERING IN JAPAN, 2011, 175 (02) : 13 - 20
  • [3] Investigation of dielectric breakdown probability distribution for double-break vacuum circuit breaker
    Shioiri, T
    Niwa, Y
    Kamikawaji, T
    Homma, M
    ISDEIV: XXTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, PROCEEDINGS, 2002, 20 : 323 - 326
  • [4] Probability distribution investigation of air breakdown
    Wei, Jin-jin
    Hu, Tao
    Zhou, Dong-fang
    WIRELESS COMMUNICATION AND SENSOR NETWORK, 2016, : 858 - 863
  • [5] Conditioning Development in Vacuum Based on Breakdown Probability Distribution
    Kojima, H.
    Otake, Y.
    Sakaki, M.
    Saito, H.
    Hasegawa, K.
    Hayakawa, N.
    PROCEEDINGS OF THE 2014 26TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV-2014), 2014, : 13 - 16
  • [6] Analysis of Conditioning and Damaging Process in Vacuum based on Breakdown Probability Distribution
    Kojima, H.
    Otake, Y.
    Takahashi, T.
    Hayakawa, N.
    Hasegawa, K.
    Saito, H.
    Sakaki, M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (01) : 43 - 48
  • [7] Investigation on Dielectric Window Treelike Breakdown and Suppression Under HPM in Vacuum
    Hao, Xi-Wei
    Zhang, Guan-Jun
    Qiu, Shi
    Huang, Wen-Hua
    Liu, Guo-Zhi
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2010, 38 (06) : 1403 - 1410
  • [8] INVESTIGATION OF BREAKDOWN IN VACUUM
    BOROVIK, ES
    BATRAKOV, BP
    SOVIET PHYSICS-TECHNICAL PHYSICS, 1958, 3 (09): : 1811 - 1818
  • [9] Three position switch based on vacuum interrupter technology suitable for disconnecting and earthing purposes
    Gentsch, D
    Fink, H
    Dullni, E
    ISDEIV: XXITH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, VOLS 1 AND 2, PROCEEDINGS, 2004, 21 : 446 - 449
  • [10] BREAKDOWN OF A SOLID-DIELECTRIC SWITCH.
    Andrezen, A.B.
    Burtsev, V.A.
    Produvnov, A.B.
    Soviet Physics, Technical Physics (English translation of Zhurnal Tekhnicheskoi Fiziki), 1975, 20 (02): : 187 - 190