In vitro evaluation of marginal microleakage and adaptation of metal-ceramic crowns luted with three types of cements.

被引:0
|
作者
Motta, B [1 ]
Pegoraro, LF [1 ]
机构
[1] USP, Dept Protese Dent, FOB, Sao Paulo, Brazil
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
引用
收藏
页码:B183 / B183
页数:1
相关论文
共 50 条
  • [31] Marginal adaptation of all-ceramic crowns using different luting-cements.
    Behr, M
    Rosentritt, M
    Lang, R
    Regnet, T
    Handel, G
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A421 - A421
  • [32] Marginal integrity after fatigue loading of ceramic inlay restorations luted with three different cements
    Abdalla, AI
    Davidson, CL
    AMERICAN JOURNAL OF DENTISTRY, 2000, 13 (02): : 77 - 80
  • [33] Radiographic evaluation of the margins of clinically acceptable metal-ceramic crowns
    Badar, Sheikh Bilal
    Zafar, Kamil
    Ghafoor, Robia
    Khan, Farhan Raza
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2022, 72 (02) : S42 - S46
  • [34] Evaluation of marginal fit of single implant-supported metal-ceramic crowns prepared by using presintered metal blocks
    Pasali, Baris
    Sarac, Duygu
    Kaleli, Necati
    Sarac, Yakup Sinasi
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (02): : 257 - 262
  • [35] In vitro evaluation of microleakage of the ceramics inlays luted with two types of resinbonded cement.
    Rocha, P
    Araujo, CRP
    Araujo, PA
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1157 - 1157
  • [36] Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology
    Quante, Katrin
    Ludwig, Klaus
    Kern, Matthias
    DENTAL MATERIALS, 2008, 24 (10) : 1311 - 1315
  • [37] Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology
    Private Dental Office, Cologne, Germany
    不详
    Dent. Mater., 10 (1311-1315):
  • [38] Marginal discrepancy of screw-retained and cemented metal-ceramic crowns on implant abutments
    Keith, SE
    Miller, BH
    Woody, RD
    Higginbottom, FL
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1999, 14 (03) : 369 - 378
  • [39] Marginal and Internal Fit of Conventional Metal-Ceramic and Lithium Disilicate CAD/CAM Crowns
    Nam, Se-Jin
    Yoon, Mi-Jung
    Kim, Won-Hee
    Ryu, Gil-Ju
    Bang, Min-Ki
    Huh, Jung-Bo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (05) : 519 - 521
  • [40] Evaluation of Microleakage Using Different Luting Cements in Kedo Zirconia Crowns: An In Vitro Assessment
    Vishnu, Guru
    Jeevanandan, Ganesh
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)