On-chip magnetic separation of superparamagnetic beads for integrated molecular analysis

被引:16
|
作者
Florescu, Octavian [1 ]
Wang, Kevan [1 ]
Au, Patrick [1 ]
Tang, Jimmy [1 ]
Harris, Eva [2 ]
Beatty, P. Robert [3 ]
Boser, Bernhard E. [1 ]
机构
[1] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Dept Publ Hlth, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Dept Mol & Cell Biol, Berkeley, CA 94720 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1063/1.3272779
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have demonstrated a postprocessed complementary metal oxide semiconductor (CMOS) integrated circuit (IC) capable of on-chip magnetic separation, i.e., removing via magnetic forces the nonspecifically bound magnetic beads from the detection area on the surface of the chip. Initially, 4.5 mu m wide superparamagnetic beads sedimenting out of solution due to gravity were attracted to the detection area by a magnetic concentration force generated by flowing current through a conductor embedded in the IC. After sedimentation, the magnetic beads that did not bind strongly to the functionalized surface of the IC through a specific biochemical complex were removed by a magnetic separation force generated by flowing current through another conductor placed laterally to the detection area. As the spherical bead pivoted on the surface of the chip, the lateral magnetic force was further amplified by mechanical leveraging, and 50 mA of current flowing through the separation conductor placed 18 mu m away from the bead resulted in 7.5 pN of tensile force on the biomolecular tether immobilizing the bead. This force proved high enough to break nonspecific interactions while leaving specific antibody-antigen bonds intact. A sandwich capture immunoassay on purified human immunoglobulin G showed strong correlation with a control enzyme linked immunosorbent assay and a detection limit of 10 ng/ml or 70 pM. The beads bound to the detection area after on-chip magnetic separation were detected optically. To implement a fully integrated molecular diagnostics platform, the on-chip magnetic separation functionality presented in this work can be readily combine with state-of-the art CMOS-based magnetic bead detection technology. (C) 2010 American Institute of Physics. [doi: 10.1063/1.3272779]
引用
收藏
页数:10
相关论文
共 50 条
  • [31] On-chip sample preconcentration for integrated microfluidic analysis
    Simon Song
    Anup K. Singh
    Analytical and Bioanalytical Chemistry, 2006, 384 : 41 - 43
  • [32] On-chip microfluidic biosensor using superparamagnetic microparticles
    Kokkinis, G.
    Keplinger, F.
    Giouroudi, I.
    BIOMICROFLUIDICS, 2013, 7 (05)
  • [33] Characterization of Superparamagnetic Particles Mobility by On-Chip Micromagnets
    Goudu, Sandhya Rani
    Hu, Xinghao
    Lim, Byeonghwa
    Kim, Kunwoo
    Kim, Keonmok
    Kim, Hyeonseol
    Yoon, Jonghwan
    Kim, CheolGi
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (06)
  • [34] On-Chip Magnetic Bead and Nanoparticle Separation in Compound Droplet EWOD
    Bansal, Shubhi
    Sen, Prosenjit
    2018 13TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS 2018), 2018, : 417 - 420
  • [35] Integrated Microfluidics for Single-Cell Separation and On-Chip Analysis: Novel Applications and Recent Advances
    Kutluk, Hazal
    Viefhues, Martina
    Constantinou, Iordania
    SMALL SCIENCE, 2024, 4 (04):
  • [36] Magnetic beads retention device for sandwich immunoassay: comparison of off-chip and on-chip antibody incubation
    Lacharme, F.
    Vandevyver, C.
    Gijs, M. A. M.
    MICROFLUIDICS AND NANOFLUIDICS, 2009, 7 (04) : 479 - 487
  • [37] On-chip manipulation of continuous picoliter-volume superparamagnetic droplets using a magnetic force
    Zhang, Kai
    Liang, Qionglin
    Ma, Sai
    Mu, Xuan
    Hu, Ping
    Wang, Yiming
    Luo, Guoan
    LAB ON A CHIP, 2009, 9 (20) : 2992 - 2999
  • [38] Magnetic beads retention device for sandwich immunoassay: comparison of off-chip and on-chip antibody incubation
    F. Lacharme
    C. Vandevyver
    M. A. M. Gijs
    Microfluidics and Nanofluidics, 2009, 7
  • [39] A compact and integrated immunoassay with on-chip dispensing and magnetic particle handling
    Zirath, Helene
    Peham, Johannes R.
    Schnetz, Guntram
    Coll, Albert
    Brandhoff, Lukas
    Spittler, Andreas
    Vellekoop, Michael J.
    Redl, Heinz
    BIOMEDICAL MICRODEVICES, 2016, 18 (01) : 1 - 9
  • [40] On-Chip Intra Decoupling Measurements for Integrated Magnetic Thin Film
    Kodate, Wataru
    Endo, Yasushi
    Yamaguchi, Masahiro
    2012 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2012, : 341 - 344