Single trial prediction of self-paced reaching directions from EEG signals

被引:51
|
作者
Lew, Eileen Y. L. [1 ,2 ]
Chavarriaga, Ricardo [1 ]
Silvoni, Stefano [3 ]
Millan, Jose del R. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Ctr Neuroprosthet, Sch Engn, Defitech Chair Noninvas Brain Machine Interface, CH-1015 Lausanne, Switzerland
[2] Univ Lausanne, Inst Psychol, Lab Expt Res Behav, Lausanne, Switzerland
[3] IRCCSS Camillo Hosp Fdn, Lab Robot & Kinemat, Venice, Italy
关键词
stroke; self-paced voluntary movement; movement-related potentials; EEG; movement direction; brain-machine interface; SLOW CORTICAL POTENTIALS; BRAIN-COMPUTER INTERFACE; HAND MOVEMENTS; AVERAGE REFERENCE; PARIETAL CORTEX; MOTOR CORTEX; PLASTICITY; PHASE; REHABILITATION; REPRESENTATION;
D O I
10.3389/fnins.2014.00222
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Early detection of movement intention could possibly minimize the delays in the activation of neuroprosthetic devices. As yet, single trial analysis using non-invasive approaches for understanding such movement preparation remains a challenging task. We studied the feasibility of predicting movement directions in self-paced upper limb center-out reaching tasks, i.e., spontaneous movements executed without an external cue that can better reflect natural motor behavior in humans. We reported results of non-invasive electroencephalography (EEG) recorded from mild stroke patients and able-bodied participants. Previous studies have shown that low frequency EEG oscillations are modulated by the intent to move and therefore, can be decoded prior to the movement execution. Motivated by these results, we investigated whether slow cortical potentials (SCPs) preceding movement onset can be used to classify reaching directions and evaluated the performance using 5-fold cross-validation. For able-bodied subjects, we obtained an average decoding accuracy of 76% (chance level of 25%) at 62.5 ms before onset using the amplitude of on-going SCPs with above chance level performances between 875 to 437.5 ms prior to onset. The decoding accuracy for the stroke patients was on average 47% with their paretic arms. Comparison of the decoding accuracy across different frequency ranges (i.e., SCPs, delta, theta, alpha, and gamma) yielded the best accuracy using SCPs filtered between 0.1 to 1 Hz. Across all the subjects, including stroke subjects, the best selected features were obtained mostly from the fronto-parietal regions, hence consistent with previous neurophysiological studies on arm reaching tasks. In summary, we concluded that SCPs allow the possibility of single trial decoding of reaching directions at least 312.5 ms before onset of reach.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A Two-class Self-Paced BCI to Control a Robot in Four Directions
    Ron-Angevin, Ricardo
    Velasco-Alvarez, Francisco
    Sancha-Ros, Salvador
    da Silva-Sauer, Leandro
    [J]. 2011 IEEE INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2011,
  • [22] Single Cell Self-Paced Clustering with Transcriptome Sequencing Data
    Zhao, Peng
    Xu, Zenglin
    Chen, Junjie
    Ren, Yazhou
    King, Irwin
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (07)
  • [23] Predictive classification of self-paced upper-limb analytical movements with EEG
    Ibanez, Jaime
    Serrano, J. I.
    del Castillo, M. D.
    Minguez, J.
    Pons, J. L.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2015, 53 (11) : 1201 - 1210
  • [24] Predictive classification of self-paced upper-limb analytical movements with EEG
    Jaime Ibáñez
    J. I. Serrano
    M. D. del Castillo
    J. Minguez
    J. L. Pons
    [J]. Medical & Biological Engineering & Computing, 2015, 53 : 1201 - 1210
  • [25] SLOW EEG POTENTIALS PRECEDING SELF-PACED PLANTAR FLEXIONS OF HAND AND FOOT
    HARI, R
    ANTERVO, A
    SALMI, T
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1983, 119 (01): : 55 - 59
  • [26] Unsupervised movement onset detection from EEG recorded during self-paced real hand movement
    Hasan, Bashar Awwad Shiekh
    Gan, John Q.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (03) : 245 - 253
  • [27] Unsupervised movement onset detection from EEG recorded during self-paced real hand movement
    Bashar Awwad Shiekh Hasan
    John Q. Gan
    [J]. Medical & Biological Engineering & Computing, 2010, 48 : 245 - 253
  • [28] SPE$∧{2}$: Self-Paced Ensemble of Ensembles for Software Defect Prediction
    Wan, Xiaohui
    Zheng, Zheng
    Liu, Yang
    [J]. IEEE TRANSACTIONS ON RELIABILITY, 2022, 71 (02) : 865 - 879
  • [29] Self-paced and Bayes-decision-rule linear KNN prediction
    Jin Zhang
    Zekang Bian
    Shitong Wang
    [J]. International Journal of Machine Learning and Cybernetics, 2022, 13 : 3267 - 3283
  • [30] Self-paced and Bayes-decision-rule linear KNN prediction
    Zhang, Jin
    Bian, Zekang
    Wang, Shitong
    [J]. INTERNATIONAL JOURNAL OF MACHINE LEARNING AND CYBERNETICS, 2022, 13 (11) : 3267 - 3283