Use of calorimetric technique for studying radiation-chemical reactions in polyethylene

被引:0
|
作者
Koptelov, AA
Karyazov, SV
Shlenskii, OF
机构
[1] Soyuz Fed Ctr Dual Technol, Dzerzhinskii 140090, Moscow Oblast, Russia
[2] Mendeleev Univ Chem Technol, Moscow 125190, Russia
关键词
D O I
暂无
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The kinetics of radiation-induced chemical processes in LDPE was studied by means of an adiabatic calorimeter, which allows the heat capacity of polymers to be measured in the course of gamma-irradiation. It was found that irradiation of virgin LDPE samples with a dose of 16 kGy was accompanied by an exothermic effect exceeding 1600 J/kg but led to an endothermic effect in the case of samples preirradiated with doses above 30 kGy. As is shown, the most likely explanations for the observed heat evolution is the reaction of disappearance of vinyl and vinylidene double bonds in the polymer. The rate of this reaction as found by calorimetric measurements is compared with data obtained by other methods.