Influence of Implant Impression Methods, Polymer Materials, and Implant Angulation on the Accuracy of Dental Models

被引:1
|
作者
Djurovic Koprivica, Daniela [1 ]
Puskar, Tatjana [1 ]
Budak, Igor [2 ]
Sokac, Mario [2 ]
Jeremic Knezevic, Milica [1 ]
Maletin, Aleksandra [1 ]
Milekic, Bojana [1 ]
Vukelic, Djordje [2 ]
机构
[1] Univ Novi Sad, Fac Med, Novi Sad 21000, Serbia
[2] Univ Novi Sad, Fac Tech Sci, Novi Sad 21000, Serbia
关键词
3D scanning; geometrical accuracy; CAD inspection; implants; polymer materials; impression materials; EDENTULOUS PATIENTS; PROSTHESES; SURVIVAL; ABUTMENT; CASTS; BONE;
D O I
10.3390/polym14142821
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The paper presents the influence of impression methods, polymer materials, and implant angulation on the accuracy of the definitive working model for the production of implant-supported dental restorations, based on the analysis of results obtained using different impression methods, materials, and parallel and angulated implants. The study findings indicate that all aforementioned factors impact the accuracy of the definitive working model. Specifically, 20 degrees implant angulation in relation to the vertical plane has a greater impact on the impression accuracy compared to parallel implants. The open and splint method in combination with addition silicone, as well as the splint method and polyether combination yielded more accurate results when using implants under 20 degrees angulation compared to other method and material combinations. The splint method in combination with addition silicone resulted in the smallest mean deviations from the center of the parallel implant base compared to other combinations of methods and materials. Analysis results further revealed statistically significant differences in the measured indicators across impression methods, implants, and polymer materials.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study
    Jo, Si-Hoon
    Kim, Kyoung-Ii
    Seo, Jae-Min
    Song, Kwang-Yeob
    Park, Ju-Mi
    Ahn, Seung-Geun
    JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (04): : 128 - 133
  • [2] Influence of Implant Angulation and Implant Number on the Accuracy of Definitive Casts
    Narayane, Abhay Kiran
    Shamsuddeen, Suhana
    Kharat, Swati
    Rashidi, Tabish
    Pandav, Aachut
    Thakur, Manoj Kumar
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (05): : 367 - 369
  • [3] Effects of Implant Angulation and Impression Coping Type on the Dimensional Accuracy of Impressions
    Shim, Ji Suk
    Ryu, Jae Jun
    Shin, Sang Wan
    Lee, Jeong Yol
    IMPLANT DENTISTRY, 2015, 24 (06) : 726 - 729
  • [4] Accuracy of five implant impression technique: effect of splinting materials and methods
    Lee, Sang-Jik
    Cho, Sung-Bum
    JOURNAL OF ADVANCED PROSTHODONTICS, 2011, 3 (04): : 177 - 185
  • [5] Effects of Implant Angulation, Impression Material, and Variation in Arch Curvature Width on Implant Transfer Model Accuracy
    Akalin, Zerrin Fidan
    Ozkan, Yasemin Kulak
    Ekerim, Ahmet
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 149 - 157
  • [6] Effect of dental implant angulation on the dimensional accuracy of master casts
    Barjini, Negar
    Sayahpour, Sahar
    Jafari, Maryam
    DENTAL AND MEDICAL PROBLEMS, 2021, 58 (04) : 473 - 482
  • [7] IMPACT OF REUSE OF DENTAL IMPLANT ANALOGS ON IMPRESSION ACCURACY
    Deniz, Sergen
    Zortuk, Mustafa
    Manav, Taha Yasar
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2025, 26 (01): : 94 - 100
  • [8] Effects of Implant Angulation, Material Selection, and Impression Technique on Impression Accuracy: A Preliminary Laboratory Study
    Rutkunas, Vygandas
    Sveikata, Kestutis
    Savickas, Raimondas
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (05) : 512 - 515
  • [9] The effects of implant angulation on the resonance frequency of a dental implant
    Harirforoush, R.
    Arzanpour, S.
    Chehroudi, B.
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (08) : 1024 - 1032
  • [10] Clinical accuracy outcomes of splinted and nonsplinted implant impression methods in dental residency settings
    Perez-Davidi, Michael
    Levit, Michael
    Walter, Ofer
    Eilat, Yuval
    Rosenfeld, Peter
    QUINTESSENCE INTERNATIONAL, 2016, 47 (10): : 843 - 852