Measurement Enhancement on Two-Dimensional Temperature Distribution of Methane-Air Premixed Flame Using SMART Algorithm in CT-TDLAS

被引:10
|
作者
Jeon, Min-Gyu [1 ,2 ]
Doh, Deog-Hee [1 ]
Deguchi, Yoshihiro [2 ]
机构
[1] Korea Maritime & Ocean Univ, Div Mech Engn, Busan 49112, South Korea
[2] Tokushima Univ, Grad Sch Adv Technol & Sci, Tokushima 7708501, Japan
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 22期
基金
新加坡国家研究基金会;
关键词
Methane-Air premixed flame; computed tomography-tunable diode laser absorption spectroscopy; temperature; concentration; burner; exhaust gas; IN-SITU MEASUREMENTS; DIODE-LASER SENSOR; HYPERSPECTRAL TOMOGRAPHY; NITRIC-OXIDE; GAS;
D O I
10.3390/app9224955
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, the temperature distribution of the Methane-Air premixed flame was measured. In order to enhance the measurement accuracy of the CT-TDLAS (Computed tomography-tunable diode laser absorption spectroscopy), the SMART (simultaneous multiplicative algebraic reconstruction technique) algorithm has been adopted. Further, the SLOS (summation of line of sight) and the CSLOS (corrective summation of line of sight) methods have been adopted to increase measurement accuracies. It has been verified that the relative error for the temperatures measured by the thermocouples and calculated by the CT-TDLAS was about 10%.