An elastomeric patch derived from poly(glycerol sebacate) for delivery of embryonic stem cells to the heart

被引:146
|
作者
Chen, Qi-Zhi [1 ]
Ishii, Hikaru [2 ]
Thouas, George A. [3 ]
Lyon, Alexander R. [2 ]
Wright, Jamie S. [2 ]
Blaker, Jonny J. [4 ]
Chrzanowski, Wojciech [5 ]
Boccaccini, Aldo R. [6 ]
Ali, Nadire N. [2 ]
Knowles, Jonathan C. [5 ]
Harding, Sian E. [2 ]
机构
[1] Monash Univ, Dept Mat Engn, Clayton, Vic 3800, Australia
[2] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, London SW7 2AZ, England
[3] Monash Univ, Div Biol Engn, Clayton, Vic 3800, Australia
[4] Univ London Imperial Coll Sci Technol & Med, Dept Chem Engn, Polymer & Composite Engn Grp, London SW7 2AZ, England
[5] UCL, Eastman Dent Inst, Div Biomat & Tissue Engn, London WC1X 8LD, England
[6] Univ London Imperial Coll Sci Technol & Med, Dept Mat, London SW7 2AZ, England
基金
英国生物技术与生命科学研究理事会;
关键词
Poly(glycerol sebacate); Embryonic stem cell; In vitro; In vivo; Heart; IN-VIVO; MYOCARDIAL TISSUE; INFARCTION; SCAFFOLDS; DEVICE; VITRO;
D O I
10.1016/j.biomaterials.2010.01.108
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We hypothesize that a combinatorial approach of ventricle constraint and stem cell therapy would offer a greater benefit for the treatment of heart failure than either strategy alone. A heart patch would serve two therapeutic purposes: biomechanical support and cell delivery. In this study, we describe a hybrid heart patch engineered from a synthetic elastomer, poly(glycerol sebacate) (PGS), supplemented with cardiomyocytes differentiated from human embryonic stem cells (hESCs). In line with two therapeutically relevant considerations, i.e. biocompatibility and cell delivery efficiency, the PGS was (a) preconditioned in culture medium for 6 days, and (b) prepared without gelatin coatings to facilitate detachment and delivery of cardiomyocytes following patch implantation. Following pre-conditioning under physiological conditions, the PGS patch material without gelatin coating was found to satisfactorily support cardiomyocyte viability and attachment, with active cell beating for periods of longer than 3 months until interrupted. Dynamic culture studies revealed that cells detached more efficiently from the uncoated surface of PGS than from gelatin-coated PGS. No significant differences were detected between the beating rates of human embryonic stem cell-derived cardiomyocytes on tissue culture plate and the pre-conditioned and gelatin-uncoated PGS. PGS patches sutured over the left ventricle of rats in vivo remained intact over a 2 week period without any deleterious effects on ventricular function. We conclude that PGS is a suitable biomaterial for stem cell-based regeneration strategies to restore cardiomyocyte function, and the hybrid heart patch engineered under optimal conditions would be a promising support device for the cardiac repair. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3885 / 3893
页数:9
相关论文
共 50 条
  • [31] Chondrocytes derived from mouse embryonic stem cells
    Jan Kramer
    Claudia Hegert
    Gunnar Hargus
    Jürgen Rohwedel
    Cytotechnology, 2003, 41 : 177 - 187
  • [32] Effect of multi-walled carbon nanotubes on the cross-linking density of the poly(glycerol sebacate) elastomeric nanocomposites
    Yan, Yi
    Sencadas, Vitor
    Jin, Tiantian
    Huang, Xufeng
    Lie, Wilford
    Wei, Dongbin
    Jiang, Zhengyi
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2018, 521 : 24 - 32
  • [33] Acrylate-modified poly( glycerol sebacate) as a photocurable ink to form 3D biodegradable and elastomeric structures
    Highley, Christopher
    Yeh, Yi-Cheun
    Ouyang, Liliang
    Burdick, Jason
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [34] Drug loaded poly(glycerol sebacate) as a local drug delivery system for the treatment of periodontal disease
    Yang, Bo
    Lv, Wei
    Deng, Ying
    RSC ADVANCES, 2017, 7 (59) : 37426 - 37435
  • [35] Elastomeric and pH-responsive hydrogels based on direct crosslinking of the poly(glycerol sebacate) pre-polymer and gelatin
    Yoon, Sungkwon
    Chen, Biqiong
    POLYMER CHEMISTRY, 2018, 9 (27) : 3727 - 3740
  • [36] Elaboration and mechanical properties of elastomeric fibrous scaffolds based on crosslinked poly(glycerol sebacate) and cyclodextrin for soft tissue engineering
    Flaig, Florence
    Faria Bellani, Caroline
    Uyumaz, Ozgun
    Schlatter, Guy
    Hebraud, Anne
    MATERIALS ADVANCES, 2021, 2 (04): : 1284 - 1293
  • [37] Differentiation roadmap of embryonic Sertoli cells derived from mouse embryonic stem cells
    Xu, Chenze
    Mohsin, Ali
    Luo, Yanxia
    Xie, Lili
    Peng, Yan
    Wang, Qizheng
    Hang, Haifeng
    Zhuang, Yingping
    Guo, Meijin
    STEM CELL RESEARCH & THERAPY, 2019, 10 (1)
  • [38] Heart tissue generated from embryonic stem cells
    Siegel-Itzkovich, Judy
    BRITISH MEDICAL JOURNAL, 2007, 334 (7586): : 174 - 175
  • [39] Differentiation roadmap of embryonic Sertoli cells derived from mouse embryonic stem cells
    Chenze Xu
    Ali Mohsin
    Yanxia Luo
    Lili Xie
    Yan Peng
    Qizheng Wang
    Haifeng Hang
    Yingping Zhuang
    Meijin Guo
    Stem Cell Research & Therapy, 10
  • [40] Electrospun Fibrous Scaffolds of Poly(glycerol-dodecanedioate) for Engineering Neural Tissues From Mouse Embryonic Stem Cells
    Dai, Xizi
    Huang, Yen-Chih
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (88):