Signal-to-background ratio and lateral resolution in deep tissue imaging by optical coherence microscopy in the 1700 nm spectral band

被引:9
|
作者
Yamanaka, Masahito [1 ]
Hayakawa, Naoki [1 ]
Nishizawa, Norihiko [1 ]
机构
[1] Nagoya Univ, Dept Elect, Chikusa Ku, Furo Cho, Nagoya, Aichi 4648603, Japan
关键词
1.7; MU-M; TOMOGRAPHY; SCATTERING; DEPTH;
D O I
10.1038/s41598-019-52175-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We quantitatively investigated the image quality in deep tissue imaging with optical coherence microscopy (OCM) in the 1700 nm spectral band, in terms of the signal-to-background ratio (SBR) and lateral resolution. In this work, to demonstrate the benefits of using the 1700 nm spectral band for OCM imaging of brain samples, we compared the imaging quality of OCM en-face images obtained at the same position by using a hybrid 1300 nm/1700 nm spectral domain (SD) OCM system with shared sample and reference arms. By observing a reflective resolution test target through a 1.5 mm-thick tissue phantom, which had a similar scattering coefficient to brain cortex tissue, we confirmed that 1700 nm OCM achieved an SBR about 6-times higher than 1300 nm OCM, although the lateral resolution of the both OCMs was similarly degraded with the increase of the imaging depth. Finally, we also demonstrated high-contrast deep tissue imaging of a mouse brain at a depth up to 1.8 mm by using high-resolution 1700 nm SD-OCM.
引用
收藏
页数:8
相关论文
共 39 条
  • [31] Long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed
    Yilei Shao
    Aizhu Tao
    Hong Jiang
    Meixiao Shen
    Dexi Zhu
    Fan Lu
    Carol L. Karp
    Yufeng Ye
    Jianhua Wang
    Eye and Vision, 5
  • [32] Long scan depth optical coherence tomography on imaging accommodation: impact of enhanced axial resolution, signal-to-noise ratio and speed
    Shao, Yilei
    Tao, Aizhu
    Jiang, Hong
    Shen, Meixiao
    Zhu, Dexi
    Lu, Fan
    Karp, Carol L.
    Ye, Yufeng
    Wang, Jianhua
    EYE AND VISION, 2018, 5
  • [33] Coregistered Spectral Optical Coherence Tomography and Two-Photon Microscopy for Multimodal Near-Instantaneous Deep-Tissue Imaging (Apr, 10.1002/cyto.a.24012, 2020)
    Zimmermann, Hanna G.
    Motamedi, Seyedamirhosein
    CYTOMETRY PART A, 2020, 97 (09) : 975 - 975
  • [34] Improving lateral resolution and image quality of optical coherence tomography by the multi-frame superresolution technique for 3D tissue imaging
    Shen, Kai
    Lu, Hui
    Baig, Sarfaraz
    Wang, Michael R.
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (11): : 4887 - 4918
  • [35] Powell lens-based line-field spectral domain optical coherence tomography system for cellular resolution imaging of biological tissue
    Chen, Keyu
    Song, Weixiang
    Han, Le
    Bizheva, Kostadinka
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (05) : 2003 - 2014
  • [36] High-resolution 1050 nm spectral domain retinal optical coherence tomography at 120 kHz A-scan rate with 6.1 mm imaging depth
    An, Lin
    Li, Peng
    Lan, Gongpu
    Malchow, Doug
    Wang, Ruikang K.
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (02): : 245 - 259
  • [37] Full-range ultrahigh-resolution spectral-domain optical coherence tomography in 1.7 μm wavelength region for deep-penetration and high-resolution imaging of turbid tissues
    Kawagoe, Hiroyuki
    Yamanaka, Masahito
    Makita, Shuichi
    Yasuno, Yoshiaki
    Nishizawa, Norihiko
    APPLIED PHYSICS EXPRESS, 2016, 9 (12)
  • [38] High-power supercontinuum generation using high-repetition-rate ultrashort-pulse fiber laser for ultrahigh-resolution optical coherence tomography in 1600 nm spectral band
    Yamanaka, Masahito
    Kawagoe, Hiroyuki
    Nishizawa, Norihiko
    APPLIED PHYSICS EXPRESS, 2016, 9 (02)
  • [39] High-Resolution Ultrasound-Switchable Fluorescence Imaging in Centimeter-Deep Tissue Phantoms with High Signal-To-Noise Ratio and High Sensitivity via Novel Contrast Agents
    Cheng, Bingbing
    Bandi, Venugopal
    Wei, Ming-Yuan
    Pei, Yanbo
    D'Souza, Francis
    Nguyen, Kytai T.
    Hong, Yi
    Yuan, Baohong
    PLOS ONE, 2016, 11 (11):