A novel algorithm for detecting active propulsion in wheelchair users following spinal cord injury

被引:37
|
作者
Popp, Werner L. [1 ,2 ]
Brogioli, Michael [2 ]
Leuenberger, Kaspar [1 ]
Albisser, Urs [2 ]
Frotzler, Angela [3 ]
Curt, Armin [2 ]
Gassert, Roger [1 ]
Starkey, Michelle L. [2 ]
机构
[1] Swiss Fed Inst Technol, Rehabil Engn Lab, Lengghalde 5, CH-8092 Zurich, Switzerland
[2] Univ Hosp Balgrist, Spinal Cord Injury Ctr, Zurich, Switzerland
[3] Swiss Parapleg Ctr, Nottwil, Switzerland
关键词
Wheelchair; Monitoring; Long-term; Algorithm; Propulsion; Spinal cord injury; Machine learning; Inertial measurement unit; PHYSICAL-ACTIVITY MONITOR; TRIAXIAL ACCELEROMETER; REAL-TIME; VALIDITY; VALIDATION;
D O I
10.1016/j.medengphy.2015.12.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Physical activity in wheelchair-bound individuals can be assessed by monitoring their mobility as this is one of the most intense upper extremity activities they perform. Current accelerometer-based approaches for describing wheelchair mobility do not distinguish between self- and attendant-propulsion and hence may overestimate total physical activity. The aim of this study was to develop and validate an inertial measurement unit based algorithm to monitor wheel kinematics and the type of wheelchair propulsion (self- or attendant-) within a "real-world" situation. Different sensor set-ups were investigated, ranging from a high precision set-up including four sensor modules with a relatively short measurement duration of 24 h, to a less precise set-up with only one module attached at the wheel exceeding one week of measurement because the gyroscope of the sensor was turned off. The "high-precision" algorithm distinguished self- and attendant-propulsion with accuracy greater than 93% whilst the long-term measurement set-up showed an accuracy of 82%. The estimation accuracy of kinematic parameters was greater than 97% for both set-ups. The possibility of having different sensor set-ups allows the use of the inertial measurement units as high precision tools for researchers as well as unobtrusive and simple tools for manual wheelchair users. (C) 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:267 / 274
页数:8
相关论文
共 50 条
  • [1] Motor learning outcomes of handrim wheelchair propulsion during active spinal cord injury rehabilitation in comparison with experienced wheelchair users
    Leving, Marika T.
    de Groot, Sonja
    Woldring, Ferry A. B.
    Tepper, Marga
    Vegter, Riemer J. K.
    van der Woude, Lucas H., V
    DISABILITY AND REHABILITATION, 2021, 43 (10) : 1429 - 1442
  • [2] The Case For Active Safety For Power Wheelchair Users With Spinal Cord Injury
    Henzel, M. Kristi
    Mitchell, Steven J.
    Lerchbacker, Joseph A.
    Majerus, Steve J. A.
    Bogie, Kath M.
    ASSISTIVE TECHNOLOGY, 2021, 33 (03) : 157 - 158
  • [3] Analysis of wheelchair propulsion in spinal cord injury rehabilitation
    Lentino, C.
    Massone, A.
    Moretto, S.
    Checchia, G. A.
    Vigo, G.
    De Luca, A.
    Basteris, A.
    Sanguineti, V.
    Zuliani, A.
    PROCEEDINGS OF THE XI EUROPEAN CONGRESS OF THE EUROPEAN FEDERATION FOR RESEARCH IN REHABILITATION, 2011, : 65 - 69
  • [4] Factors related to propulsion efficiency in manual wheelchair users with paraplegia due to spinal cord injury
    Curi, Haidar Tafner
    de Lima, Jaqueline
    Ferretti, Eliana Chaves
    CADERNOS BRASILEIROS DE TERAPIA OCUPACIONAL-BRAZILIAN JOURNAL OF OCCUPATIONAL THERAPY, 2020, 28 (03): : 999 - 1019
  • [5] Changes in supraspinatus and biceps tendon thickness: influence of fatiguing propulsion in wheelchair users with spinal cord injury
    Fransiska M. Bossuyt
    Michael L. Boninger
    Ann Cools
    Nathan Hogaboom
    Inge Eriks-Hoogland
    Ursina Arnet
    Spinal Cord, 2020, 58 : 324 - 333
  • [6] Changes in supraspinatus and biceps tendon thickness: influence of fatiguing propulsion in wheelchair users with spinal cord injury
    Bossuyt, Fransiska M.
    Boninger, Michael L.
    Cools, Ann
    Hogaboom, Nathan
    Eriks-Hoogland, Inge
    Arnet, Ursina
    SPINAL CORD, 2020, 58 (03) : 324 - 333
  • [7] Wheelchair Skills Capacity and Performance of Manual Wheelchair Users With Spinal Cord Injury
    Kirby, R. Lee
    Worobey, Lynn A.
    Cowan, Rachel.
    Pedersen, Jessica Presperin
    Heinemann, Allen W.
    Dyson-Hudson, Trevor A.
    Shea, Mary
    Smith, Cher
    Rushton, Paula W.
    Boninger, Michael. L.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2016, 97 (10): : 1761 - 1769
  • [8] Biomechanical Analysis of the Propulsion of the Manual Wheelchair in Patients with Spinal Cord Injury
    Quinones-Uriostegui, I.
    Bernal-Yescas, F.
    Tovar-Sandoval, J. A.
    Vela-Pena, E.
    Bourdon-Santoyo, M.
    Perez-Sanpablo, A. I.
    2014 PAN AMERICAN HEALTH CARE EXCHANGES (PAHCE), 2014,
  • [9] KINEMATICS OF WHEELCHAIR PROPULSION IN ADULTS AND CHILDREN WITH SPINAL-CORD INJURY
    BEDNARCZYK, JH
    SANDERSON, DJ
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1994, 75 (12): : 1327 - 1334
  • [10] The Effect of External Power Output and Its Reliability on Propulsion Technique Variables in Wheelchair Users With Spinal Cord Injury
    de Groot, Sonja
    Cowan, Rachel E.
    MacGillivray, Megan K.
    Leving, Marika T.
    Sawatzky, Bonita J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2022, 30 : 296 - 304