Imaging of peripheral arteries by 16-row multidetector computed tomography angiography: A feasible tool?

被引:14
|
作者
Mishra, Anuj
Bhaktarahalli, Jahnavi Narayanaswamy
Ehtuish, Ehtuish F.
机构
[1] Natl Organ Transplant Program, Dept Radiol, Tripoli, Libya
[2] Tripoli Med Ctr, Dept Clin Pathol, Tripoli, Libya
[3] Natl Organ Transplant Program, Dept Surg, Tripoli, Libya
关键词
multidetector CT angiography; peripheral arterial occlusive disease; catheter angiography;
D O I
10.1016/j.ejrad.2006.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the efficacy of multi detector(16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral arterial occlusive disease (PAOD). Methods: Thirty-three patients underwent MDCT angiography (MDCTA) of the upper or the lower limb on 16-row MDCT scanner between November, 2004 and July, 2005. The findings were compared with the surgical outcome in cases with trauma and suspected arterial injuries or color Doppler correlation was obtained for patients of PAOD. Results: MDCTA allowed a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In the 23 cases of PAOD, MDCT adequately demonstrated the presence of stenosis or occlusion, its degree and extent, the presence of collaterals and plaques. Conclusion: Our experience of CT angiography (CTA) with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries and as a useful screening modality in cases of PAOD for diagnosis and for grading. (C) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:528 / 533
页数:6
相关论文
共 50 条
  • [31] 16-row multislice computer tomography coronary angiography in stable angina pectoris
    Mollet, N
    EUROPEAN HEART JOURNAL, 2004, 25 : 369 - 369
  • [32] CT-angiography with a 16-row CT scanner for perioperative evaluation of the hepatic arteries
    Bitschnau, S
    Oberholzer, K
    Kreitner, KF
    Otto, G
    Thelen, M
    Mildenberger, P
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (11): : 1634 - 1640
  • [33] Multidetector-row computed tomography imaging of splenic trauma
    Marmery, Helen
    Shanmuganathan, K.
    SEMINARS IN ULTRASOUND CT AND MRI, 2006, 27 (05) : 404 - 419
  • [34] Radiation dose in multidetector row computed tomography cardiac imaging
    Bae, KT
    Hong, C
    Whiting, BR
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (06) : 859 - 863
  • [35] Accuracy of 16-row multislice computed tomographic angiography for assessment of small cerebral aneurysms
    Chen, Wenhua
    Wang, Jie
    Xin, Wei
    Peng, Ya
    Xu, Qing
    NEUROSURGERY, 2008, 62 (01) : 113 - 121
  • [36] A morphological study of the inferior phrenic arteries on multidetector computed tomography and angiography
    Pavlov, Roman
    Belbl, Miroslav
    Krecek, Jan
    Palous, Daniel
    Adla, Theodor
    Kachlik, David
    Whitley, Adam
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2024, 254
  • [37] Multiple Renal Arteries: Variations Demonstrated by Multidetector Computed Tomography Angiography
    Koplay, Mustafa
    Onbas, Omer
    Alper, Fatih
    Gulcan, Erim
    Kantarci, Mecit
    MEDICAL PRINCIPLES AND PRACTICE, 2010, 19 (05) : 412 - 414
  • [38] Multidetector-row computed tomography
    El-Khoury, GY
    Bennett, DL
    Ondr, GJ
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2004, 12 (01) : 1 - 5
  • [39] 16-row multidetector CT angiography of the aortoiliac system and lower extremity arteries: Contrast enhancement and image quality using a standarized examination protocol
    Meyer, BC
    Ribbe, C
    Kruschewski, M
    Wolf, KJ
    Albrecht, T
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (11): : 1562 - 1570
  • [40] Errors in multidetector row computed tomography
    M. A. Mazzei
    L. Volterrani
    La radiologia medica, 2015, 120 : 785 - 794