Simultaneous determination of the five HIV-protease inhibitors: Amprenavir, indinavir, nelfinavir, ritonavir, and saquinavir in human plasma by solid-phase extraction and column liquid chromatography

被引:23
|
作者
Poirier, JM [1 ]
Radembino, N [1 ]
Robidou, P [1 ]
Jaillon, P [1 ]
机构
[1] St Antoine Univ Hosp, Dept Pharmacol, F-75571 Paris 12, France
关键词
liquid chromatography; solid-phase extraction; HIV-protease inhibitors;
D O I
10.1097/00007691-200008000-00017
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A sensitive and selective liquid chromatographic assay has been developed for the determination of the five protease inhibitors currently approved by the Food and Drug Administration (FDA) (amprenavir, indinavir; nelfinavir, ritonavir, and saquinavir) in a single run. Pretreatment of a 1-mL plasma sample spiked with internal standard was made by a solid-phase extraction procedure using a polymeric reversed-phase sorbent. Liquid chromatography was performed using a narrowbore C18 reversed-phase column and gradient elution. A double ultraviolet detection at 265 nm (amprenavir) and at 210 nm (indinavir, nelfinavir, ritonavir, saquinavir and internal standard) was used. Calibration curves were linear in the range 25-10000 ng/mL and the assay has been validated over the range 25-5000 ng/mL. Average accuracy at four concentrations was in the range of 100.5-104.2% and 96.9-100.5% for within-day and between-day. respectively. The coefficients of variation were less than 10%. Mean absolute recoveries varied from 85.4% (ritonavir) to 98.8% (saquinavir). No metabolite of the protease inhibitors was found to coelute with the drugs of interest or with the internal standard. At this time, among the tested drugs, especially all the presently licensed nucleoside and nonnucleoside reverse transcriptase inhibitors that can be used a combination with the protease inhibitors, none was found to interfere with the assay. This method is now in use in the authors' laboratory for the therapeutic monitoring of the HIV-protease inhibitors.
引用
收藏
页码:465 / 473
页数:9
相关论文
共 50 条
  • [31] Determination of a HIV protease inhibitor (DMP 450) in animal and human plasma by solid-phase extraction and high-performance liquid chromatography
    Grubb, MF
    Robinson, CA
    White, SJ
    Krauthauser, CL
    Shum, LY
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 678 (02): : 303 - 308
  • [32] Simultaneous determination of six HIV protease inhibitors, one metabolite, and two non-nucleoside reverse transcriptase inhibitors in human plasma by isocratic reversed-phase liquid chromatography after solid-phase extraction
    Faux, J
    Venisse, N
    Le Moal, G
    Dupuis, A
    Bouquet, S
    [J]. CHROMATOGRAPHIA, 2003, 58 (7-8) : 421 - 426
  • [33] Simultaneous Determination of Six HIV Protease Inhibitors, One Metabolite, and Two Non-nucleoside Reverse Transcriptase Inhibitors in Human Plasma by Isocratic Reversed-Phase Liquid Chromatography After Solid-Phase Extraction
    J. Faux
    N. Venisse
    G. Le Moal
    A. Dupuis
    S. Bouquet
    [J]. Chromatographia, 2003, 58 : 421 - 426
  • [34] The HIV protease inhibitors saquinavir, ritonavir, and nelfinavir but not indinavir impair the epithelial barrier in the human intestinal cell line HT-29/B6
    Bode, H
    Schmidt, W
    Schulzke, JD
    Fromm, M
    Zippel, T
    Wahnschaffe, U
    Bendfeldt, K
    Riecken, EO
    Ullrich, R
    [J]. AIDS, 1999, 13 (18) : 2595 - 2597
  • [35] Determination of clozapine in human plasma by solid-phase extraction and liquid chromatography with amperometric detection
    M. A. Raggi
    F. Bugamelli
    R. Mandrioli
    D. De Ronchi
    V. Volterra
    [J]. Chromatographia, 1998, 47 : 8 - 12
  • [36] Determination of clozapine in human plasma by solid-phase extraction and liquid chromatography with amperometric detection
    Raggi, MA
    Bugamelli, F
    Mandrioli, R
    De Ronchi, D
    Volterra, V
    [J]. CHROMATOGRAPHIA, 1998, 47 (1-2) : 8 - 12
  • [37] Determination of Ligustrazine in Human Plasma by High Performance Liquid Chromatography with Solid-Phase Extraction
    Weng Weiyu
    Shen Teng
    Xu Huinan
    Zhang Jianfang
    Huang Jianming
    Huang Zhaochang
    Cai Jia
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (03) : 276 - 278
  • [38] Determination of atazanavir and other antiretroviral drugs (indinavir, amprenavir, nelfinavir and its active metabolite M8, saquinavir, ritonavir, lopinavir, nevirapine and efavirenz) plasma levels by high performance liquid chromatography with UV detection
    Dailly, E
    Raffi, F
    Jolliet, P
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 353 - 358
  • [39] Simultaneous determination of the enantiomers of esmolol and its acid metabolite in human plasma by reversed phase liquid chromatography with solid-phase extraction
    Tang, YH
    He, Y
    Yao, TW
    Zeng, S
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (02): : 249 - 254
  • [40] Determination of cotinine in plasma by liquid chromatography after solid-phase extraction
    Dunn, EJ
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (13) : 2043 - 2050