Current source design for electrical impedance tomography

被引:105
|
作者
Ross, AS [1 ]
Saulnier, GJ
Newell, JC
Isaacson, D
机构
[1] Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY 12180 USA
[2] Rensselaer Polytech Inst, Dept Elect & Comp Syst Engn, Troy, NY 12180 USA
[3] Rensselaer Polytech Inst, Dept Math Sci, Troy, NY 12180 USA
关键词
electrical impedance imaging; electrical impedance tomography; current source; generalized impedance converter;
D O I
10.1088/0967-3334/24/2/361
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Questions regarding the feasibility of using electrical impedance tomography (EIT) to detect breast cancer may be answered by building a sufficiently precise multiple frequency EIT instrument. Current sources are desirable for this application, yet no current source designs have been reported that have the required precision at the multiple frequencies needed. We have designed an EIT current source using an enhanced Howland topology in parallel with a generalized impedance converter (GIC). This combination allows for nearly independent adjustment of output resistance and output capacitance, resulting in simulated output impedances in excess of 2 GOmega between 100 Hz and I MHz. In this paper, the theoretical operation of this current source is explained, and experimental results demonstrate the feasibility of creating a high precision, multiple frequency, capacitance compensated current source for EIT applications.
引用
收藏
页码:509 / 516
页数:8
相关论文
共 50 条
  • [21] Design of electrodes and current limits for low frequency electrical impedance tomography of the brain
    Gilad, O.
    Horesh, L.
    Holder, D. S.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (07) : 621 - 633
  • [22] Design of electrodes and current limits for low frequency electrical impedance tomography of the brain
    O. Gilad
    L. Horesh
    D. S. Holder
    Medical & Biological Engineering & Computing, 2007, 45 : 621 - 633
  • [23] Current patterns and electrode types for single-source electrical impedance tomography of the thorax
    Schuessler, TF
    Bates, JHT
    ANNALS OF BIOMEDICAL ENGINEERING, 1998, 26 (02) : 253 - 259
  • [24] Design of a microscopic electrical impedance tomography system using two current injections
    Liu, Qin
    Oh, Tong In
    Wi, Hun
    Lee, Eun Jung
    Seo, Jin Keun
    Woo, Eung Je
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (09) : 1505 - 1516
  • [25] Current Sources for Electrical Impedance Tomography IMPETOM
    Sanchez, Pablo
    David, Marcelo
    Gonzalez, Mariana
    Morales, Isabel
    Simini, Franco
    ADVANCES IN BIOENGINEERING AND CLINICAL ENGINEERING, VOL 1, SABI 2023, 2024, 106 : 233 - 248
  • [26] Current injection electrodes for electrical impedance tomography
    Armstrong, S
    Jennings, D
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (04) : 797 - 802
  • [27] Probe current sources for electrical impedance tomography
    Brazovskii K.S.
    Pekker J.S.
    Soldatov A.I.
    Biomedical Engineering, 2016, 49 (6) : 349 - 353
  • [28] On optimal current patterns for electrical impedance tomography
    Demidenko, E
    Hartov, A
    Soni, N
    Paulsen, KD
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (02) : 238 - 248
  • [29] A WIDE-BAND AC-COUPLED CURRENT SOURCE FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    BRAGOS, R
    ROSELL, J
    RIU, P
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 : A91 - A99
  • [30] An electrical impedance tomography system for current pulse measurements
    Kovacic, D
    Santic, A
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 255 - 257