Long ablation cycles result in increased depth of multi-electrode ablation lesions using pulsed radiofrequency energy

被引:0
|
作者
McRury, I [1 ]
Schlichting, A [1 ]
Wilson, C [1 ]
Diamond, S [1 ]
机构
[1] Bard Electrophysiol, Lowell, MA USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A RF controller that sequentially distributes RF energy to up to 4 electrodes in 5ms pulses was used to create linear lesions in vitro and in vivo. A quad-polar ablation catheter with four 4mm electrodes was used for the ablation of bovine myocardium in blood at 60 degrees C with 50W. The temperature, energy, and lesion shape were measured from ablations of 1, 2, 3, 4, and 5 minutes. Results were compared to 2 and 5-minute ablations performed in. vivo. All the lesions were continuous. In vitro, lesion depth increased with ablation cycle and was directly proportional to energy (R=0.89). Lesion length was approximately 28mm in all cases. In vivo 2 min vs. 5 min lesion depth was 3.5+/-0.7 vs. 4.8+/-0.7mm (p=0.01),with similar length (20+/-8 vs. 24+/-8mm) and temperature (46+/-5 vs. 47+/-4 degrees C). It can be concluded that lesion depth of ablations from multiple electrodes increases with increasing ablation duration.
引用
收藏
页码:851 / 855
页数:5
相关论文
共 50 条
  • [31] One-year follow-up after irrigated multi-electrode radiofrequency ablation of persistent atrial fibrillation
    Pavlovic, Nikola
    Sticherling, Christian
    Knecht, Sven
    Reichlin, Tobias
    Muehl, Aline
    Schaer, Beat
    Osswald, Stefan
    Kuehne, Michael
    EUROPACE, 2016, 18 (01): : 85 - 91
  • [32] Atrial Fibrillation Ablation with a Novel Fully 3D-Mapping-Integrated Multi-Electrode Radiofrequency Balloon Catheter
    Teumer, Yannick
    Miesbichler, Clemens
    Hauke, Andreas
    Katov, Lyuboslav
    Bothner, Carlo
    Pott, Alexander
    Mueller, Martin
    Walter, Benjamin
    Rottbauer, Wolfgang
    Dahme, Tillman
    Weinmann, Karolina
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (01)
  • [33] Ablation of atrial fibrillation in the rapid pacing canine model using a multi-electrode loop catheter
    Avitall, B
    Urbonas, A
    Millard, S
    Urboniene, D
    Helms, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (06) : 1733 - 1740
  • [34] Ultrastructural insights from myocardial ablation lesions from microsecond pulsed field vs radiofrequency energy
    Kawamura, Iwanari
    Wang, Bingyan J.
    Nies, Moritz
    Watanabe, Keita
    Chaudhry, Hina W.
    Maejima, Yasuhiro
    Sasano, Tetsuo
    Gordon, Ronald
    Dukkipati, Srinivas R.
    Reddy, Vivek Y.
    Koruth, Jacob
    HEART RHYTHM, 2024, 21 (04) : 389 - 396
  • [35] Comparison of pulsed versus continuous radiofrequency energy delivery: Diameter of lesions induced with multipolar ablation catheter
    Erdogan, A
    Carlsson, J
    Roederich, H
    Schulte, B
    Sperzel, J
    Berkowitsch, A
    Neuzner, J
    Pitschner, HF
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (11): : 1852 - 1855
  • [36] Efficacy of multiple ring and coil electrode radiofrequency ablation catheters for the creation of long linear lesions in the atria
    McRury, ID
    Haines, DE
    MEDICAL ENGINEERING & PHYSICS, 1998, 20 (08) : 551 - 557
  • [37] Pulmonary vein isolation for persistent atrial fibrillation using a novel gold multi-electrode duty cycled radiofrequency ablation catheter, first results
    Spitzer, S. G.
    Langbein, A.
    Raemmler, C.
    Scharfe, F.
    Weinmann, T.
    Otto, T.
    Karolyi, L.
    EUROPEAN HEART JOURNAL, 2015, 36 : 730 - 730
  • [38] Safety of pulmonary vein isolation and left atrial complex fractionated atrial electrograms ablation for atrial fibrillation with phased radiofrequency energy and multi-electrode catheters
    Mulder, Anton A. W.
    Bait, Jippe C.
    Wijffels, Maurits C. E. F.
    Weyer, Eric F. D.
    Boersma, Lucas V. A.
    EUROPACE, 2012, 14 (10): : 1433 - 1440
  • [39] Efficacy of multi-electrode duty-cycled radiofrequency ablation for pulmonary vein disconnection in patients with paroxysmal and persistent atrial fibrillation
    Beukema, Rypko P.
    Beukema, Willem P.
    Smit, Jaap Jan J.
    Misier, Anand R. Ramdat
    Delnoij, Peter Paul H. M.
    Wellens, Hein
    Elvan, Arif
    EUROPACE, 2010, 12 (04): : 502 - 507
  • [40] Multi-electrode ablation with duty-cycled low power bipolar/uniplolar RF energy for chronic AF
    Boersma, L. V. A.
    Scharf, C.
    Davies, W.
    Kanagaratnam, P.
    Paul, V.
    Rowland, E.
    Grace, A.
    Fyn, S.
    Oral, H.
    Morady, F.
    EUROPEAN HEART JOURNAL, 2008, 29 : 410 - 410