Long ablation cycles result in increased depth of multi-electrode ablation lesions using pulsed radiofrequency energy

被引:0
|
作者
McRury, I [1 ]
Schlichting, A [1 ]
Wilson, C [1 ]
Diamond, S [1 ]
机构
[1] Bard Electrophysiol, Lowell, MA USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A RF controller that sequentially distributes RF energy to up to 4 electrodes in 5ms pulses was used to create linear lesions in vitro and in vivo. A quad-polar ablation catheter with four 4mm electrodes was used for the ablation of bovine myocardium in blood at 60 degrees C with 50W. The temperature, energy, and lesion shape were measured from ablations of 1, 2, 3, 4, and 5 minutes. Results were compared to 2 and 5-minute ablations performed in. vivo. All the lesions were continuous. In vitro, lesion depth increased with ablation cycle and was directly proportional to energy (R=0.89). Lesion length was approximately 28mm in all cases. In vivo 2 min vs. 5 min lesion depth was 3.5+/-0.7 vs. 4.8+/-0.7mm (p=0.01),with similar length (20+/-8 vs. 24+/-8mm) and temperature (46+/-5 vs. 47+/-4 degrees C). It can be concluded that lesion depth of ablations from multiple electrodes increases with increasing ablation duration.
引用
收藏
页码:851 / 855
页数:5
相关论文
共 50 条
  • [1] Conventional radiofrequency catheter ablation compared to multi-electrode ablation for atrial fibrillation
    Gal, Pim
    Aarntzen, Alissa E. S. M.
    Smit, Jaap Jan J.
    Adiyaman, Ahmet
    Misier, Anand R. Ramdat
    Delnoy, Peter Paul H. M.
    Elvan, Arif
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 176 (03) : 891 - 895
  • [2] Lesion Characteristics Using a Novel Multi-Electrode Radiofrequency Balloon Ablation Catheter
    Lee, Byron K.
    Al-Ahmad, Amin
    Rippy, Marian
    Reddy, Vivek
    Narayan, Girish
    Kuck, Karl-Heinz
    Crozier, Ian
    Daly, Matt
    Melton, Iain
    Walters, Tomas E.
    Lee, Randall J.
    Badhwar, Nitish
    CIRCULATION, 2016, 134
  • [3] Site localization of painful lesions during radiofrequency ablation of pulmonary veins using circular multi-electrode catheters
    Laish-Farkash, Avishag
    Katz, Amos
    Cohen, Ornit
    Osherov, Azriel
    Bruocha, Sharon
    Khalameizer, Vladimir
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 45 (01) : 63 - 69
  • [4] Site localization of painful lesions during radiofrequency ablation of pulmonary veins using circular multi-electrode catheters
    Avishag Laish-Farkash
    Amos Katz
    Ornit Cohen
    Azriel Osherov
    Sharon Bruocha
    Vladimir Khalameizer
    Journal of Interventional Cardiac Electrophysiology, 2016, 45 : 63 - 69
  • [5] Pulsed radiofrequency energy and multi-electrode catheters: Comparison of two different monitoring modes for ablation of porcine right atrium
    Kongsgaard, E
    O'Callaghan, P
    Maarouf, N
    Rowland, E
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 88A - 88A
  • [6] Characterization of lesions in swine atrium using novel multi-electrode ablation catheters
    Wijffels, M. C. E. F.
    Van Oosterhout, M. F.
    Vos, M. A.
    Beekman, J. D.
    Boersma, L. V. A.
    EUROPEAN HEART JOURNAL, 2008, 29 : 412 - 412
  • [7] The Use of the Multi-Electrode Duty-Cycled Radiofrequency Ablation Catheter PVAC for the Ablation of a Left Atrial Tachycardia
    Leftheriotis, Dionyssios
    Flevari, Panayota
    Simeonidou, Eftihia
    Niokou, Dimitra
    Anastasiou-Nana, Maria
    HELLENIC JOURNAL OF CARDIOLOGY, 2012, 53 (02) : 163 - 167
  • [8] Radiofrequency catheter ablation of frequent premature ventricular contractions using ARRAY multi-electrode balloon catheter
    Dubner, Sergio
    Hadid, Claudio
    Azocar, Damian
    Labadet, Carlos
    Valsecchi, Cecilia
    Dominguez, Agustin
    CARDIOLOGY JOURNAL, 2016, 23 (01) : 17 - 22
  • [9] A comparative study on computational models of multi-electrode radiofrequency ablation of large liver tumors
    Audigier, Chloe
    Mohaiu, Antonia Teodora
    Alzaga, Amilcar
    Bale, Reto
    Mansi, Tommaso
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (08) : 1489 - 1496
  • [10] A comparative study on computational models of multi-electrode radiofrequency ablation of large liver tumors
    Chloé Audigier
    Antonia Teodora Mohaiu
    Amilcar Alzaga
    Reto Bale
    Tommaso Mansi
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 1489 - 1496