Electrochemical determination of meloxicam in pharmaceutical preparation and biological fluids using oxidized glassy carbon electrodes

被引:14
|
作者
Farhadi, Khalil [1 ]
Karimpour, Ahmad [1 ]
机构
[1] Urmia Univ, Fac Sci, Dept Chem, Orumiyeh, Iran
关键词
meloxicam; electrochemical determination; stripping; biological fluids;
D O I
10.1248/cpb.55.638
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The adsorptive and electrochemical behaviors of meloxicam (MLC) was investigated on a glassy carbon electrode that was electrochemically treated by anodic oxidation at +1.8 V, following potential cycling in the potential range from -0.8 to 1.0 V vs. Ag/AgCl reference electrode. The resulting electrode showed a good activity to improve the electrochemical response of the drug. MLC was accumulated at an electrochemically activated glassy carbon electrode (phosphate buffer pH 6) in a certain time and then determined by linear sweep voltammetry. The oxidative peak currents showed a linear function in the concentration ranges of 0.02 to 10,um using a 240 s preconcentration time. The preconcentration medium-exchange approach was utilized for the selective determination of the drug in spiked urine and plasma samples with satisfactory results. The recovery values of the proposed method obtained 105% (RSD 2.5%) and 100% (RSD 1.8%) for urine and plasma samples, respectively. Also, the proposed method has been successfully used for determination of MLC in tablets.
引用
收藏
页码:638 / 642
页数:5
相关论文
共 50 条
  • [41] Electrochemical Preparation of a MIP-Glassy Carbon Electrode for the Determination of Dimethoate
    Capoferri, Denise
    Del Carlo, Michele
    Ntshongontshi, Nomaphelo
    Iwuoha, Emmanuel I.
    Compagnone, Dario
    SENSORS, 2018, 431 : 157 - 162
  • [42] Electrochemical determination of Sudan IV in food samples by using graphene-modified glassy carbon electrodes
    Chen, Meifeng
    Ma, Xinying
    Li, Xia
    TURKISH JOURNAL OF CHEMISTRY, 2013, 37 (06) : 959 - 965
  • [43] Voltammetric determination of meloxicam in pharmaceutical formulation and human serum at glassy carbon electrode modified by cysteic acid formed by electrochemical oxidation of L-cysteine
    Wang, Cheng Yin
    Wang, Zhi Xian
    Guan, Jun
    Hu, Xiao Ya
    SENSORS, 2006, 6 (09) : 1139 - 1152
  • [44] Electrochemical oxidation of butein at glassy carbon electrodes
    Yamil Tesio, Alvaro
    Noel Robledo, Sebastian
    Fernandez, Hector
    Alicia Zon, Maria
    BIOELECTROCHEMISTRY, 2013, 91 : 62 - 69
  • [45] Electrochemical Sensing of Anesthetics using Polythiophene Coated Glassy Carbon Electrodes
    Ramkumar, Ramya
    Sangaranarayanan, M. V.
    CHEMISTRYSELECT, 2019, 4 (33): : 9776 - 9783
  • [46] ELECTROCHEMICAL PRETREATMENT OF GLASSY-CARBON ELECTRODES
    ENGSTROM, RC
    ANALYTICAL CHEMISTRY, 1982, 54 (13) : 2310 - 2314
  • [47] Sensitive and selective electrochemical determination of doxycycline in pharmaceutical formulations using poly(dipicrylamine) modified glassy carbon electrode
    Gashu, Mulu
    Kassa, Adane
    Tefera, Molla
    Amare, Meareg
    Aragaw, Belete Asefa
    SENSING AND BIO-SENSING RESEARCH, 2022, 37
  • [48] DIRECT ELECTROCHEMICAL DETERMINATION OF ADENINE USING HPMFP-MODIFIED GLASSY CARBON ELECTRODE IN COMMERCIAL PHARMACEUTICAL PRODUCTS
    Song, Yun
    Li, Jin-Zhou
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2011, 39 (03) : 261 - 272
  • [49] A study on oxidized glassy carbon sheets for bipolar supercapacitor electrodes
    Braun, A
    Bärtsch, M
    Geiger, F
    Schnyder, B
    Kötz, R
    Haas, O
    Carlen, M
    Christen, T
    Ohler, C
    Unternährer, P
    Krause, E
    NEW MATERIALS FOR BATTERIES AND FUEL CELLS, 2000, 575 : 369 - 380
  • [50] PREPARATION OF GLASSY CARBON ELECTRODES FOR STRIPPING VOLTAMMETRY
    MIWA, T
    TOYOTA, T
    MIZUIKE, A
    BUNSEKI KAGAKU, 1975, 24 (12) : 792 - 794