An Internet service for manipulating 3D models of human organs reconstructed from computer tomography and magnetic resonance imaging

被引:2
|
作者
Clapworthy, G
Krokos, M
Vasilonikolidakis, N
机构
[1] De Montfort Univ, Dept Comp & Informat Sci, Milton Keynes MK7 6HP, Bucks, England
[2] Neuroware, Dept Res & Dev, Athens 10433, Greece
关键词
distributed databases; 3D volumetric models; human pathologies; interactive manipulation; World Wide Web;
D O I
10.1016/S1386-5056(97)00093-2
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Our paper describes an integrated methodology addressing the development of an Internet service for medical professionals, medical students and generally, people interested in medicine. The service (currently developed in the framework of IAEVA, a Telematics Application Programme project of the European Union), incorporates a mechanism for retrieving from a relational database (reference library) 3D volumetric models of human organs reconstructed from computer tomography (CT) and/or magnetic resonance imaging (MRI). Retrieval is implemented in a way transparent to the actual physical location of the database. Prospective users are provided with a Solid Object Viewer that offers them manipulation (rotation, zooming, dissection etc.) of 3D volumetric models. The service constitutes an excellent foundation of understanding for medical professionals/students and a mechanism for broad and rapid dissemination of information related to particular pathological conditions; although pathological conditions of the knee and skin are supported currently, our methodology allows easy service extension into other human organs ultimately covering the entire human body. The service accepts most Internet browsers and supports MS-Windows 32 platforms; no graphics accelerators or any specialised hardware are necessary, thereby allowing service availability to the widest possible audience. Nevertheless, the service operates in near real-time not only over high speed expensive network lines but also over low/medium network connections. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:121 / 124
页数:4
相关论文
共 50 条
  • [21] Myocardial strains from 3D displacement encoded magnetic resonance imaging
    Katarina Kindberg
    Henrik Haraldsson
    Andreas Sigfridsson
    Jan Engvall
    Neil B Ingels
    Tino Ebbers
    Matts Karlsson
    BMC Medical Imaging, 12
  • [22] Myocardial strains from 3D displacement encoded magnetic resonance imaging
    Kindberg, Katarina
    Haraldsson, Henrik
    Sigfridsson, Andreas
    Engvall, Jan
    Ingels, Neil B., Jr.
    Ebbers, Tino
    Karlsson, Matts
    BMC MEDICAL IMAGING, 2012, 12
  • [23] Usefulness of 3D reconstructed computed tomography imaging for double outlet right ventricle
    Chen, Shyh-Jye
    Lin, Ming-Tai
    Liu, Kao-Lang
    Chang, Chung-I
    Chen, Hsu-Yi
    Wang, Jou-Kou
    Lee, Wen-Jeng
    Tsang, Yuk-Ming
    Li, Yiu-Wah
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2008, 107 (05) : 371 - 380
  • [24] Femoroacetabular impingement with chronic acetabular rim fracture - 3D computed tomography, 3D magnetic resonance imaging and arthroscopic correlation
    Chhabra, Avneesh
    Nordeck, Shaun
    Wadhwa, Vibhor
    Madhavapeddi, Sai
    Robertson, William J.
    WORLD JOURNAL OF ORTHOPEDICS, 2015, 6 (06): : 498 - 504
  • [25] Modelling of the 3D geometry in the human rectum based on magnetic resonance imaging (MRI)
    Frokjaer, JB
    McMahon, BP
    Liao, DH
    Drewes, AM
    Gregersen, H
    GASTROENTEROLOGY, 2004, 126 (04) : A202 - A203
  • [26] Reconstructed human 3D tissue models in toxicology: from initial idea to the regulatory acceptance
    Kandarova, H.
    TOXICOLOGY LETTERS, 2022, 368 : S10 - S11
  • [27] Rhinoplasty Pre-Surgery Models by Using Low-Dose Computed Tomography, Magnetic Resonance Imaging, and 3D Printing
    Baldi, Dario
    Basso, Luca
    Nele, Gisella
    Federico, Giovanni
    Antonucci, Giuseppe Walter
    Salvatore, Marco
    Cavaliere, Carlo
    DOSE-RESPONSE, 2021, 19 (04):
  • [28] Automatic magnetic resonance imaging segmentation of the eye based on 3D Active Shape Models
    Ciller, Carlos
    De Zanet, Sandro Ivo
    Pica, Alessia
    Thiran, Jean-Philippe
    Maeder, Philippe
    Munier, Francis L.
    Kowal, Jens Horst
    Cuadra, Meritxell Bach
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [29] Hemodynamics of human carotid artery bifurcations: Computational studies with models reconstructed from magnetic resonance imaging of normal subjects
    Milner, JS
    Moore, JA
    Rutt, BK
    Steinman, DA
    JOURNAL OF VASCULAR SURGERY, 1998, 28 (01) : 143 - 156
  • [30] Comparison of computed tomography and 3D magnetic resonance imaging in evaluating glenohumeral instability bone loss
    Lander, Sarah T.
    Liles, Jordan L.
    Kim, Billy I.
    Taylor, Dean C.
    Lau, Brian C.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (11) : 2217 - 2224