Effect of Exercise Protocol on Deoxy[Hb plus Mb]: Incremental Step versus Ramp Exercise

被引:38
|
作者
Boone, Jan [1 ,2 ]
Koppo, Katrien [3 ]
Barstow, Thomas J. [4 ]
Bouckaert, Jacques [1 ,2 ]
机构
[1] Univ Ghent, Dept Movement & Sports Sci, B-9000 Ghent, Belgium
[2] Ghent Univ Hosp, Ctr Sports Med, Ghent, Belgium
[3] Univ Ghent, Dept Pharmacol, B-9000 Ghent, Belgium
[4] Kansas State Univ, Dept Kinesiol, Manhattan, KS 66506 USA
来源
关键词
NIRS; SIGMOID MODEL; DEOXYGENATION; MUSCLE BLOOD FLOW; DIFFERENT FIBER TYPES; NEAR-INFRARED SPECTROSCOPY; PULMONARY O-2 UPTAKE; MUSCLE BLOOD-FLOW; CARDIOVASCULAR-RESPONSES; CYCLE ERGOMETRY; CARDIAC-OUTPUT; GAS-EXCHANGE; RAT MUSCLES; DEOXYGENATION;
D O I
10.1249/MSS.0b013e3181c0ecea
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
BOONE, J., K. KOPPO, T. J. BARSTOW, and J. BOUCKAERT. Effect of Exercise Protocol on Deoxy[Hb + Mb]: Incremental Step versus Ramp Exercise. Med. Sci. Sports Exerc., Vol. 42, No. 5, pp. 935-942, 2010. Purpose: The aim of the present study was to investigate whether the sigmoid pattern of deoxy[Hb + Mb] during incremental exercise is specific to non-steady-state conditions. Methods: Ten highly trained cyclists performed an incremental step (40 W.3 min(-1)) and ramp (35 W.min(-1)) exercise. Deoxy[Hb + Mb] was measured at the distal and proximal sites of the musculus vastus lateralis throughout the exercises using near- infrared spectroscopy. Deoxy[Hb + Mb] was set out as a function of work rate (% peak power), and using curve-fitting techniques, the best-fitting model was determined. Results: These procedures showed that the sigmoid pattern also provided the best fit for the pattern of deoxy[ Hb + Mb] in the step exercise. Furthermore, it was observed that the sigmoid model was similar for the ramp (d = 6.9% T 1.1% and 6.9% +/- 1.4%.%(-1) peak power; c/d = 52.1% +/- 3.8% and 52.1% +/- 4.5% peak power, for the proximal and distal measurement sites, respectively) and the step exercise (d = 7.4% +/- 1.5% and 6.4% +/- 1.5%.%(-1) peak power; c/d = 52.3% +/- 6.0% and 52.5% +/- 4.2% peak power, for the proximal and distal measurement sites, respectively). The pattern of deoxy[Hb + Mb] was not influenced by measurement site. Conclusions: From the present study, it can be concluded that the sigmoid pattern of deoxy[Hb + Mb] during incremental exercise is not specific to non-steady-state conditions. It was hypothesized that this pattern is an expression of a nonlinear (Q) over dot(m)/(V) over dotO(2m) relationship, related to changes in muscle fiber-type recruitment.
引用
收藏
页码:935 / 942
页数:8
相关论文
共 50 条
  • [11] CORRELATION OF THE PHYSIOLOGICAL-PARAMETERS OF A CONTINUOUS RAMP VERSUS AN INCREMENTAL JAMES EXERCISE PROTOCOL IN NORMAL-CHILDREN
    TANNER, CS
    HEISE, CT
    BARBER, G
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (04): : 309 - 312
  • [12] Characterizing Oxy[Hb plus Mb] and Deoxy[Hb plus Mb] Changes During Post Occlusion Reactive Hyperemia
    Bopp, Christopher M.
    Townsend, Dana K.
    Barstow, Thomas J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S310 - S310
  • [13] Evaluation of the "Step-Ramp-Step" Protocol: Accurate Aerobic Exercise Prescription with Different Steps and Ramp Slopes
    Mackie, Mary Z.
    Iannetta, Danilo
    Keir, Daniel A.
    Murias, Juan M.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (05) : 990 - 998
  • [14] The constant work rate critical power protocol overestimates ramp incremental exercise performance
    Black, Matthew I.
    Jones, Andrew M.
    Kelly, James A.
    Bailey, Stephen J.
    Vanhatalo, Anni
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2016, 116 (11-12) : 2415 - 2422
  • [15] The constant work rate critical power protocol overestimates ramp incremental exercise performance
    Matthew I. Black
    Andrew M. Jones
    James A. Kelly
    Stephen J. Bailey
    Anni Vanhatalo
    European Journal of Applied Physiology, 2016, 116 : 2415 - 2422
  • [16] A treadmill ramp protocol using simultaneous changes in speed and grade - A (ramp) step forward in exercise testing
    Myers, J
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (09): : 1604 - 1604
  • [17] A modified step-ramp-step protocol to prescribe constant-speed exercise in treadmill running
    Faricier, Robin
    Micheli, Lorenzo
    Guluzade, Nasimi A.
    Murias, Juan M.
    Keir, Daniel A.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2024, 124 (11) : 3445 - 3455
  • [18] Systemic versus Peripheral Adjustments of Blood Flow and Oxygen Extraction During Ramp Incremental Exercise
    Keir, Daniel A.
    Murias, Juan M.
    Spencer, Matthew D.
    Paterson, Donald H.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 516 - 516
  • [19] Comparison of ramp versus step protocols for exercise testing in patients ≥60 years of age
    Bader, DS
    Maguire, TE
    Balady, GJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (01): : 11 - 14
  • [20] COMPARISON OF THE RAMP VERSUS STANDARD EXERCISE PROTOCOLS
    MYERS, J
    BUCHANAN, N
    WALSH, D
    KRAEMER, M
    MCAULEY, P
    HAMILTONWESSLER, M
    FROELICHER, VF
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (06) : 1334 - 1342