Fast GC-MS of endocrine disrupting chemicals

被引:8
|
作者
Huskova, Renata [1 ]
Matisova, Eva [1 ]
Ondrekova, Silvia [1 ]
Durcanska, Jarmila [2 ]
机构
[1] Slovak Tech Univ Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, Slovakia
[2] State Vet & Food Inst Bratislava, Bratislava 84252, Slovakia
关键词
fast GC-MS; endocrine disrupting pesticides; calibration approaches; analyte protectants; non-fatty food; ultratrace analysis; FAST GAS-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; PESTICIDE-RESIDUES ANALYSIS; MASS-SPECTROMETRY; ANALYTE PROTECTANTS; WATER SAMPLES; ULTRATRACE ANALYSIS; BABY FOOD; INJECTION; MATRICES;
D O I
10.1080/03067310902871273
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method has been developed and evaluated for the determination of endocrine disrupting chemicals (EDCs) - pesticides in non-fatty food. Twenty-nine analytes of different chemical classes according to EDCs draft list of European Commision were selected. The method is based on fast GC-MS with bench top quadrupole MS detector and electron impact (EI) ionisation (70 eV). For the effective separation programme temperature vaporiser (PTV) injector and narrow-bore column were used. Slightly modified QuEChERS sample preparation technique was applied for the preparation of apple extracts for matrix-matched standards, synthetic sample and real sample extracts. Two internal standards (I. S.) - heptachlor (HPT) and triphenylphosphate (TPP) - were used. The results needed for the method validation were calculated from absolute peak areas and normalised areas to HPT and TPP. The important part of the study is the utilisation of analyte protectants (APs). Three calibrations approaches: matrix-matched standards without/with APs and acetonitrile (MeCN) standards with APs were used. The best results were obtained with matrix-matched standards without APs. The developed and validated analytical method was used for the identification and quantification of EDCs pesticides in real samples (orange, lettuce, strawberry and plum).
引用
收藏
页码:173 / 187
页数:15
相关论文
共 50 条
  • [21] Passive sampling and stir bar sorptive extraction for the determination of endocrine-disrupting compounds in water by GC-MS
    Emanuele Magi
    Marina Di Carro
    Camilla Liscio
    [J]. Analytical and Bioanalytical Chemistry, 2010, 397 : 1335 - 1345
  • [22] GC-MS determination of endocrine disruption compounds in extractants
    Yao, W.
    Luan, H.-L.
    [J]. Kuang Yeh/Mining and Metallurgy, 2001, 10 (03): : 82 - 86
  • [23] Fast GC-MS in supersonic molecular beams
    Amirav, A
    Dagan, S
    [J]. ISRAEL JOURNAL OF CHEMISTRY, 1997, 37 (04) : 475 - 482
  • [24] GC OR GC-MS
    PRATZEL, B
    STURINO, E
    [J]. POLLUTION ENGINEERING, 1983, 15 (08) : 28 - 29
  • [25] Cryptorchidism and endocrine disrupting chemicals
    Virtanen, Helena E.
    Adamsson, Annika
    [J]. MOLECULAR AND CELLULAR ENDOCRINOLOGY, 2012, 355 (02) : 208 - 220
  • [26] Detection of endocrine disrupting chemicals
    Koizumi, M
    Hasegawa, R
    [J]. JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 1999, 40 (02): : J203 - J207
  • [27] Toxicity of endocrine disrupting chemicals
    Mitsumori, K
    [J]. JOURNAL OF PESTICIDE SCIENCE, 1999, 24 (01): : 93 - 94
  • [28] Endocrine-Disrupting Chemicals
    Gore, Andrea C.
    [J]. JAMA INTERNAL MEDICINE, 2016, 176 (11) : 1705 - 1706
  • [29] Endocrine disrupting chemicals and endometriosis
    Smarr, Melissa M.
    Kannan, Kurunthachalam
    Louis, Germaine M. Buck
    [J]. FERTILITY AND STERILITY, 2016, 106 (04) : 959 - 966
  • [30] Endocrine disrupting chemicals and bone
    Turan, Serap
    [J]. BEST PRACTICE & RESEARCH CLINICAL ENDOCRINOLOGY & METABOLISM, 2021, 35 (05)