Role of electrolyte additives on in-vitro corrosion behavior of DC plasma electrolytic oxidization coatings formed on Cp-Ti

被引:40
|
作者
Hariprasad, S. [1 ]
Ashfaq, M. [2 ]
Arunnellaiappan, T. [1 ]
Harilal, Manu [3 ]
Rameshbabu, N. [1 ]
机构
[1] Natl Inst Technol, Dept Met & Mat Engn, Tiruchirappalli 620015, Tamil Nadu, India
[2] King Saud Univ, Coll Engn, Adv Mfg Inst, FARCAMT Chair, Riyadh 11421, Saudi Arabia
[3] Amal Jyothi Coll Engn, Dept Met, Kottayam 686518, Kerala, India
来源
关键词
Cp-Ti; Plasma electrolytic oxidation; Electrolyte chemistry; Corrosion resistance; Bioactivity; Cell adhesion; OXIDIZED TITANIA FILMS; SURFACE MODIFICATION; CELL RESPONSE; DUTY CYCLE; OXIDATION; PERFORMANCE; FABRICATION; SI;
D O I
10.1016/j.surfcoat.2016.03.016
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The present investigation reports the effect of different electrolyte additives on in-vitro corrosion behavior of the plasma electrolytic oxidation (PEO) coatings formed on commercially pure titanium (Cp-Ti). PEO coatings were produced using a pulsed DC power source at a constant current density of 70 mA/cm(2) and a treatment time of 8 min. Different coatings were developed with different additives (sodium sulfate, Tris, di-ammonium hydrogen phosphate and ammonium acetate) added to a base electrolyte consisting of TSOP and KOH. PEO coatings were characterized for phase composition, elemental composition, surface and cross-sectional microstructure, corrosion behavior, apatite forming ability and osteoblast cell adhesion. The corrosion resistance of the developed oxide coatings was evaluated in a Kokubo simulated body fluid (SBF) by potentiodynamic polarization test and EIS study. The in-vitro bioactivity of all the PEO coatings and the untreated substrate was studied by soaking the samples in an SBF environment for 21 days. The TiO2 layer formed in phosphate, sulfate and nitrite containing electrolyte highly enhances the apatite formation in SBF. An in-vitro cell adhesion test was performed on all coatings using human osteosarcoma cells for 48 h. SEM images of cell adhesion test showed that human osteosarcoma cells were well adhered and spread on all PEO treated samples. Among all the additives, Tris has provided higher corrosion resistance in the SBF environment with good apatite forming ability and osteoblast cell adhesion. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 29
页数:10
相关论文
共 50 条
  • [21] Corrosion Behavior of Ta-10W Coatings on CP-Ti and TC4 Substrates
    Sun, Pei
    Gu, Yi
    Li, Yaqi
    Liu, Baoshan
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2019, 28 (07) : 4152 - 4162
  • [22] Role of electrolyte composition on structural, morphological and in-vitro biological properties of plasma electrolytic oxidation films formed on zirconium
    Sandhyarani, M.
    Prasadrao, T.
    Rameshbabu, N.
    APPLIED SURFACE SCIENCE, 2014, 317 : 198 - 209
  • [23] Corrosion Behavior of Ta-10W Coatings on CP-Ti and TC4 Substrates
    Pei Sun
    Yi Gu
    Yaqi Li
    Baoshan Liu
    Journal of Materials Engineering and Performance, 2019, 28 : 4152 - 4162
  • [24] Study of Coatings Formed on Zirconium Alloy by Plasma Electrolytic Oxidation in Electrolyte with Submicron Yttria Powder Additives
    Savushkina, Svetlana
    Gerasimov, Mikhail
    Apelfeld, Andrey
    Suminov, Igor
    METALS, 2021, 11 (09)
  • [25] Plasma Electrolytic Oxidation (PEO) Process on Commercially Pure Ti Surface: Effects of Electrolyte on the Microstructure and Corrosion Behavior of Coatings
    Fattah-Alhosseini, Arash
    Keshavarz, Mohsen K.
    Molaei, Maryam
    Gashti, Seyed Omid
    METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2018, 49A (10): : 4966 - 4979
  • [26] Plasma Electrolytic Oxidation (PEO) Process on Commercially Pure Ti Surface: Effects of Electrolyte on the Microstructure and Corrosion Behavior of Coatings
    Arash Fattah-Alhosseini
    Mohsen K. Keshavarz
    Maryam Molaei
    Seyed Omid Gashti
    Metallurgical and Materials Transactions A, 2018, 49 : 4966 - 4979
  • [27] The Electrochemical Corrosion Behavior of Plasma Electrolytic Oxidation Coatings Fabricated on Aluminum in Silicate Electrolyte
    Yang, Zhong
    Wang, Rui-qiang
    Liu, Chen
    Wu, Ye-kang
    Wang, Dong-dong
    Liu, Xin-tong
    Zhang, Xu-zhen
    Wu, Guo-rui
    Shen, De-jiu
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2019, 28 (06) : 3652 - 3660
  • [28] The Electrochemical Corrosion Behavior of Plasma Electrolytic Oxidation Coatings Fabricated on Aluminum in Silicate Electrolyte
    Zhong Yang
    Rui-qiang Wang
    Chen Liu
    Ye-kang Wu
    Dong-dong Wang
    Xin-tong Liu
    Xu-zhen Zhang
    Guo-rui Wu
    De-jiu Shen
    Journal of Materials Engineering and Performance, 2019, 28 : 3652 - 3660
  • [29] Formation of bioactive hydroxyapatite-containing titania coatings on CP-Ti 4+alloy generated by plasma electrolytic oxidation
    Lederer, S.
    Sankaran, S.
    Smith, T.
    Fuerbeth, W.
    SURFACE & COATINGS TECHNOLOGY, 2019, 363 : 66 - 74
  • [30] Influence of sodium aluminate concentration and process duration on microstructure, mechanical and electrochemical behavior of PEO coatings formed on CP-Ti
    Malinovschi, V
    Marin, A.
    Ducu, C.
    Andrei, V
    Coaca, E.
    Craciun, Valentin
    Lungu, Mihail
    SURFACE & COATINGS TECHNOLOGY, 2021, 418