Appropriate use criteria in clinical routine practice: implications in a nuclear cardiology lab

被引:5
|
作者
Gimelli, Alessia [1 ]
Rovai, Ilaria [2 ]
Liga, Riccardo [2 ]
Pasanisi, Emilio Maria [1 ]
Marzullo, Paolo [1 ,3 ]
机构
[1] Fdn Toscana Gabriele Monasterio, Via Moruzzi 1, I-56124 Pisa, Italy
[2] Univ Hosp Pisa, Pisa, Italy
[3] CNR, Inst Clin Physiol, Via Savi 8, I-56100 Pisa, Italy
来源
关键词
Appropriate use criteria; Myocardial perfusion imaging; Ischaemic heart disease; SPECT; COMPUTED-TOMOGRAPHY; TEMPORAL TRENDS; RADIATION; DISEASE; IMPACT;
D O I
10.1007/s10554-016-0864-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The efforts for a broad application of the appropriate use criteria to reduce inappropriate nuclear stress testing have frequently been unsuccessful and the reported rates of inappropriateness have varied widely between studies. We sought to analyze the criteria of clinical appropriateness of a cohort of consecutive patients referred to our nuclear cardiology laboratory to perform stress myocardial perfusion imaging (MPI) and to assess the relationships between test appropriateness and the evaluation of ischaemia. A cohort of 251 consecutive patients, admitted to our Institute from January to March 2015, who underwent stress/rest MPI on a dedicated cardiac camera equipped with cadmium-zinc-telluride detectors, was selected. The level of clinical appropriateness of each MPI test was categorized in each patient according to the AUC criteria. According to the accepted criteria, the majority of the MPI stress-tests could be classified as clinically appropriate (218 of 251, 87 % of the tests), while only 16 (6 %) and 17 (7 %) resulted of uncertain appropriateness or clearly inappropriate, respectively. Of the 251 appropriate tests, 22 (10 %), 65 (30 %), and 131 (60 %) showed the presence of a mild (SDS < 4), moderate (4 a parts per thousand yen SDS < 7), and severe (SDS a parts per thousand yen 7) ischemic burden, respectively, while none of the inappropriate test showed moderate-to-severe ischaemia (P < 0.001 for comparisons). The rate of inappropriate MPI tests is considerably low in a high-volume laboratory. Appropriate and inappropriate studies identify patients at high and low probability of significant ischemia, respectively, providing insights on the effects of the level of appropriateness on stress-test results.
引用
收藏
页码:1003 / 1009
页数:7
相关论文
共 50 条
  • [21] Nuclear Cardiology: Basic and Advanced Concepts in Clinical Practice
    AlJaroudi, Wael
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (04) : 1775 - 1780
  • [22] Electron beam tomography: Current practice and implications for nuclear cardiology
    Hecht, HS
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (06) : 714 - 721
  • [23] The routine use of Cedilanid in clinical practice
    Parsonnet, AE
    Bernstein, A
    [J]. AMERICAN HEART JOURNAL, 1943, 26 (01) : 39 - 41
  • [24] Electron beam tomography: Current practice and implications for nuclear cardiology
    Harvey S. Hecht
    [J]. Journal of Nuclear Cardiology, 2000, 7 : 714 - 721
  • [25] Use of clinical guidelines in cardiology practice in Sudan
    Elsadig, Hwaida
    Weiss, Marjorie
    Scott, Jenny
    Laaksonen, Raisa
    [J]. JOURNAL OF EVALUATION IN CLINICAL PRACTICE, 2018, 24 (01) : 127 - 134
  • [26] Implications of SENSE MR in routine clinical practice
    van den Brink, JS
    Watanabe, Y
    Kuhl, CK
    Taylor, C
    Muthupillai, R
    Van Cauteren, M
    Yamada, K
    Dymarkowski, S
    Bogaert, J
    Maki, JH
    Matos, C
    Casselman, JW
    Hoogeveen, RM
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2003, 46 (01) : 3 - 27
  • [27] Utility of the AAOS Appropriate Use Criteria (AUC) for Pediatric Supracondylar Humerus Fractures in Clinical Practice
    Ibrahim, Talal
    Hegazy, Abdelsalam
    Abulhail, Safa I. S.
    Ghomrawi, Hassan M. K.
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2017, 37 (01) : 14 - 19
  • [28] An Evaluation of Industry Relationships Among Contributors to AAOS Clinical Practice Guidelines and Appropriate Use Criteria
    Checketts, Jake X.
    Cook, Courtney
    Vassar, Matt
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (02):
  • [29] Usability of the AAOS Appropriate Use Criteria (AUC) for the surgical management of knee osteoarthritis in clinical practice
    Ghalib Oudah Ahmed
    Kareem ELSweify
    Abdulaziz F. Ahmed
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 2077 - 2081
  • [30] Usability of the AAOS Appropriate Use Criteria (AUC) for the surgical management of knee osteoarthritis in clinical practice
    Ahmed, Ghalib Oudah
    ElSweify, Kareem
    Ahmed, Abdulaziz F.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (07) : 2077 - 2081