Appropriate use criteria in clinical routine practice: implications in a nuclear cardiology lab

被引:5
|
作者
Gimelli, Alessia [1 ]
Rovai, Ilaria [2 ]
Liga, Riccardo [2 ]
Pasanisi, Emilio Maria [1 ]
Marzullo, Paolo [1 ,3 ]
机构
[1] Fdn Toscana Gabriele Monasterio, Via Moruzzi 1, I-56124 Pisa, Italy
[2] Univ Hosp Pisa, Pisa, Italy
[3] CNR, Inst Clin Physiol, Via Savi 8, I-56100 Pisa, Italy
来源
关键词
Appropriate use criteria; Myocardial perfusion imaging; Ischaemic heart disease; SPECT; COMPUTED-TOMOGRAPHY; TEMPORAL TRENDS; RADIATION; DISEASE; IMPACT;
D O I
10.1007/s10554-016-0864-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The efforts for a broad application of the appropriate use criteria to reduce inappropriate nuclear stress testing have frequently been unsuccessful and the reported rates of inappropriateness have varied widely between studies. We sought to analyze the criteria of clinical appropriateness of a cohort of consecutive patients referred to our nuclear cardiology laboratory to perform stress myocardial perfusion imaging (MPI) and to assess the relationships between test appropriateness and the evaluation of ischaemia. A cohort of 251 consecutive patients, admitted to our Institute from January to March 2015, who underwent stress/rest MPI on a dedicated cardiac camera equipped with cadmium-zinc-telluride detectors, was selected. The level of clinical appropriateness of each MPI test was categorized in each patient according to the AUC criteria. According to the accepted criteria, the majority of the MPI stress-tests could be classified as clinically appropriate (218 of 251, 87 % of the tests), while only 16 (6 %) and 17 (7 %) resulted of uncertain appropriateness or clearly inappropriate, respectively. Of the 251 appropriate tests, 22 (10 %), 65 (30 %), and 131 (60 %) showed the presence of a mild (SDS < 4), moderate (4 a parts per thousand yen SDS < 7), and severe (SDS a parts per thousand yen 7) ischemic burden, respectively, while none of the inappropriate test showed moderate-to-severe ischaemia (P < 0.001 for comparisons). The rate of inappropriate MPI tests is considerably low in a high-volume laboratory. Appropriate and inappropriate studies identify patients at high and low probability of significant ischemia, respectively, providing insights on the effects of the level of appropriateness on stress-test results.
引用
收藏
页码:1003 / 1009
页数:7
相关论文
共 50 条
  • [1] Appropriate use criteria in clinical routine practice: implications in a nuclear cardiology lab
    Alessia Gimelli
    Ilaria Rovai
    Riccardo Liga
    Emilio Maria Pasanisi
    Paolo Marzullo
    [J]. The International Journal of Cardiovascular Imaging, 2016, 32 : 1003 - 1009
  • [2] Pediatric Appropriate Use Criteria for Echocardiography: Implications for Clinical Practice
    Sachdeva, Ritu
    Samai, Cyrus
    Vincent, Robert N.
    [J]. PEDIATRICS, 2015, 135 (05) : E1128 - E1130
  • [3] Two Perspectives of the Appropriate Use Criteria in Cardiology Practice: Advantageousand Useful or Limiting and Harmful?
    Krishnan, Sandeep K.
    Bahia, Amit
    Brindis, Ralph G.
    Lepor, Norman E.
    Itchhaporia, Dipti
    Patel, Pranav M.
    [J]. REVIEWS IN CARDIOVASCULAR MEDICINE, 2017, 18 (02) : 73 - 77
  • [4] APPLYING APPROPRIATE USE CRITERIA FOR TRANSTHORACIC ECHOCARDIOGRAPHY TO CLINICAL PRACTICE
    Robbins, Zach
    Burgess, Malcolm
    Harrison, Ben
    [J]. HEART, 2017, 103 : A89 - A89
  • [5] Nuclear cardiology in clinical practice
    Appleby, MA
    Pennell, DJ
    [J]. HOSPITAL MEDICINE, 1999, 60 (03): : 183 - 186
  • [6] Comparative utility of appropriate use criteria versus clinical practice guidelines
    Brandon Worley
    Rachel Kyllo
    Vishnu Harikumar
    Bianca Y. Kang
    Sarah A. Ibrahim
    Ian A. Maher
    Joseph F. Sobanko
    Todd V. Cartee
    Nour Kibbi
    Joshua L. Owen
    Kelly A. Reynolds
    Diana Bolotin
    Abigail H. Waldman
    Kira Minkis
    Brian Petersen
    M. Laurin Council
    Kishwer S. Nehal
    Y. Gloria Xu
    S. Brian Jiang
    Murad Alam
    [J]. Archives of Dermatological Research, 2022, 314 : 381 - 383
  • [7] Comparative utility of appropriate use criteria versus clinical practice guidelines
    Worley, Brandon
    Kyllo, Rachel
    Harikumar, Vishnu
    Kang, Bianca Y.
    Ibrahim, Sarah A.
    Maher, Ian A.
    Sobanko, Joseph F.
    Cartee, Todd, V
    Kibbi, Nour
    Owen, Joshua L.
    Reynolds, Kelly A.
    Bolotin, Diana
    Waldman, Abigail H.
    Minkis, Kira
    Petersen, Brian
    Council, M. Laurin
    Nehal, Kishwer S.
    Xu, Y. Gloria
    Jiang, S. Brian
    Alam, Murad
    [J]. ARCHIVES OF DERMATOLOGICAL RESEARCH, 2022, 314 (04) : 381 - 383
  • [8] Understanding Appropriate Use Criteria in Nuclear Medicine
    Farrell, Mary Beth
    Cerqueira, Manuel D.
    [J]. JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2012, 40 (02) : 81 - 86
  • [9] The appropriate use criteria: Improvements for its integration into real world clinical practice
    Klein, Lloyd W.
    Tamis-Holland, Jacqueline
    Kirtane, Ajay J.
    Anderson, H. Vernon
    Cigarroa, Joaquin
    Duffy, Peter L.
    Blankenship, James
    Valentine, C. Michael
    Welt, Frederick G. P.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (07) : 1349 - 1357
  • [10] ACC Appropriate Use Criteria Methodology: 2018 Update A Report of the American College of Cardiology Appropriate Use Criteria Task Force
    Hendel, Robert C.
    Lindsay, Bruce D.
    Allen, Joseph M.
    Brindis, Ralph G.
    Patel, Manesh R.
    White, Leah
    Winchester, David E.
    Wolk, Michael J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (08) : 935 - 948