A portable detection system for in vivo monitoring of 131I in routine and emergency situations

被引:0
|
作者
Lucena, E. A. [1 ]
Dantas, A. L. A. [1 ]
Dantas, B. M. [1 ]
机构
[1] CNEN, Inst Radioprotecao & Dosimetria, Av Salvador Allende S-N, BR-22780160 Rio De Janeiro, RJ, Brazil
关键词
D O I
10.1088/1742-6596/975/1/012058
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In vivo monitoring of I-131 in human thyroid is often used to evaluate occupational exposure in nuclear medicine facilities and in the case of accidental intakes in nuclear power plants for the monitoring of workers and population. The device presented in this work consists on a Pb-collimated NaI(Tl) 3"x3" scintillation detector assembled on a tripod and connected to a portable PC. The evaluation of the applicability and limitations of the system is based on the estimation of the committed effective doses associated to the minimum detectable activities in different facilities. It has been demonstrated that the system is suitable for use in routine and accidental situations.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Thyroid uptake test with portable device (COTI) after 131I tracer administration: proof of concept
    Mohammad Abuqbeitah
    Mustafa Demir
    Nami Yeyin
    Sait Sager
    David Gray
    Radiation and Environmental Biophysics, 2020, 59 : 553 - 558
  • [42] Thyroid uptake test with portable device (COTI) after 131I tracer administration: proof of concept
    Abuqbeitah, Mohammad
    Demir, Mustafa
    Yeyin, Nami
    Sager, Sait
    Gray, David
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2020, 59 (03) : 553 - 558
  • [43] Portable Alcohol Detection System for Driver Monitoring
    Wakana, Hironori
    Yamada, Masuyoshi
    2019 IEEE SENSORS, 2019,
  • [44] Performance analysis of different methods to determine 131I in water samples for environmental monitoring
    A. Rodríguez
    J. A. Corbacho
    N. Dickson
    E. Tovar
    A. Baeza
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 317 : 1071 - 1078
  • [45] Radiation Monitoring of an Isolation Room for 131I Therapy After the Patients Were Released
    Karo, Choeung
    Ideguchi, Reiko
    Nishi, Kodai
    Fukuda, Naoko
    Miura, Miwa
    Matuda, Naoki
    Kudo, Takashi
    HEALTH PHYSICS, 2019, 117 (04): : 419 - 425
  • [46] A methodology for auto-monitoring of internal contamination by 131I in nuclear medicine workers
    Vidal, M. V. S.
    Dantas, A. L. A.
    Dantas, B. M.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 483 - 487
  • [47] A PORTABLE, HIGH-RESOLUTION GAMMA-RAY SPECTROMETER FOR ROUTINE AND EMERGENCY MONITORING
    COOPER, EL
    HEALTH PHYSICS, 1983, 44 (06): : 713 - 713
  • [48] Performance analysis of different methods to determine 131I in water samples for environmental monitoring
    Rodriguez, A.
    Corbacho, J. A.
    Dickson, N.
    Tovar, E.
    Baeza, A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 317 (02) : 1071 - 1078
  • [49] Comparison of 131I whole-body imaging, 131I SPECT/CT, and 18F-FDG PET/CT in the detection of metastatic thyroid cancer
    Oh, Jong-Ryool
    Byun, Byung-Hyun
    Hong, Sun-Pyo
    Chong, Ari
    Kim, Jahae
    Yoo, Su-Woong
    Kang, Sae-Ryung
    Kim, Dong-Yeon
    Song, Ho-Chun
    Bom, Hee-Seung
    Min, Jung-Joon
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (08) : 1459 - 1468
  • [50] Comparison of 131I whole-body imaging, 131I SPECT/CT, and 18F-FDG PET/CT in the detection of metastatic thyroid cancer
    Jong-Ryool Oh
    Byung-Hyun Byun
    Sun-Pyo Hong
    Ari Chong
    Jahae Kim
    Su-Woong Yoo
    Sae-Ryung Kang
    Dong-Yeon Kim
    Ho-Chun Song
    Hee-Seung Bom
    Jung-Joon Min
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 1459 - 1468