A portable detection system for in vivo monitoring of 131I in routine and emergency situations

被引:0
|
作者
Lucena, E. A. [1 ]
Dantas, A. L. A. [1 ]
Dantas, B. M. [1 ]
机构
[1] CNEN, Inst Radioprotecao & Dosimetria, Av Salvador Allende S-N, BR-22780160 Rio De Janeiro, RJ, Brazil
关键词
D O I
10.1088/1742-6596/975/1/012058
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In vivo monitoring of I-131 in human thyroid is often used to evaluate occupational exposure in nuclear medicine facilities and in the case of accidental intakes in nuclear power plants for the monitoring of workers and population. The device presented in this work consists on a Pb-collimated NaI(Tl) 3"x3" scintillation detector assembled on a tripod and connected to a portable PC. The evaluation of the applicability and limitations of the system is based on the estimation of the committed effective doses associated to the minimum detectable activities in different facilities. It has been demonstrated that the system is suitable for use in routine and accidental situations.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Development of Portable Thyroid Monitoring System for 131I and 133I in Nuclear Emergency
    Jang, Mee
    Kim, Hyun Ki
    Choi, Chang Woon
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 428 - 431
  • [2] Effectiveness of an Imaging Plate System in Emergency 131I Thyroid Monitoring
    Deji, Shizuhiko
    Li, Xiaojuan
    Ito, Shigeki
    Hirota, Masahiro
    Saze, Takuya
    Nishizawa, Kunihide
    HEALTH PHYSICS, 2018, 115 (02): : 221 - 226
  • [3] In vivo thyroid 131I monitoring system using an imaging plate
    Hirota, M
    Saze, T
    Nishizawa, K
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 457 - 460
  • [4] In vivo thyroid 131I monitoring system using an imaging plate
    Hirota, M
    Saze, T
    Nishizawa, K
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A457 - A460
  • [5] Characterization of an in vivo thyroid 131I monitoring system using an imaging plate
    Hirota, Masahiro
    Saze, Takuya
    Nishizawa, Kunihide
    Appl. Radiat. Isot., 5 (733-740):
  • [6] Characterization of an in vivo thyroid 131I monitoring system using an imaging plate
    Hirota, M
    Saze, T
    Nishizawa, K
    APPLIED RADIATION AND ISOTOPES, 2004, 60 (05) : 733 - 740
  • [7] Feasibility of in vivo thyroid 131I monitoring with an imaging plate
    Hirota, M
    Saze, T
    Ogata, Y
    Nishizawa, K
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (04) : 513 - 516
  • [8] Development of a calibration system for airborne 131I monitoring devices
    Zhao, C.
    Tang, F.
    He, L.
    Xu, Y.
    Lu, X.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 460 - 464
  • [9] Design and evaluation of portable shielding case for thyroid 131I monitoring by imaging plate
    Li, Xiao Juan
    Tang, Jing Chun
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 295 (02) : 1177 - 1180
  • [10] Establishing a Protocol for Quick Estimation of Thyroid Internal Contamination with 131I in Normal and Emergency Situations
    Naderi, S. Mehdizadeh
    Karimipourfard, M.
    Lotfalizadeh, F.
    Zamani, E.
    Molaeimanesh, Z.
    Sadeghi, M.
    Entezarmahdi, M.
    Sina, S.
    Faghihi, R.
    MEDICAL PHYSICS, 2015, 42 (06) : 3260 - 3260