Fast-rate residual generator based on multiple slow-rate sensors

被引:8
|
作者
Geng, Hang [1 ]
Liang, Yan [1 ]
Zhang, Xiaojing [1 ]
Yang, Feng [1 ]
机构
[1] Northwestern Polytech Univ, Sch Automat, Xian 710072, Peoples R China
基金
美国国家科学基金会;
关键词
sensor fusion; signal detection; eigenvalues and eigenfunctions; signal sampling; signal generators; fast-rate residual generator; multiple slow-rate sensors; fast-rate fault detection; casuality constraint; left eigenvector assignment; disturbance-decoupling; multisensor model; multirate sensor sampling; MULTIRATE SAMPLED-DATA; RATE FAULT-DETECTION; DATA SYSTEMS;
D O I
10.1049/iet-spr.2013.0296
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study puts forward the problem of fast-rate fault detection based on multiple slow-rate sensors. A fast-rate residual generator with casuality constraint is established from the multi-sensor model. Parameters of the residual generator are determined via disturbance-decoupling based on left eigenvector assignment. It is found that the condition of disturbance-decoupling is related to the multi-rate sensor sampling nature. A numerical example is given to illustrate the effectiveness of the proposed residual generator.
引用
收藏
页码:878 / 884
页数:7
相关论文
共 50 条
  • [31] A bioreactor for subjecting cultured cells to fast-rate intermittent hypoxia
    Tsapikouni, Theodora
    Garreta, Elena
    Melo, Esther
    Navajas, Daniel
    Farre, Ramon
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2012, 182 (01) : 47 - 52
  • [32] REMOVAL OF TRACE-LEVEL ORGANICS BY SLOW-RATE LAND TREATMENT
    PARKER, LV
    JENKINS, TF
    WATER RESEARCH, 1986, 20 (11) : 1417 - 1426
  • [33] ACCELERATION OF SINUS RHYTHM DURING SLOW-RATE ATRIAL-PACING
    HABERL, R
    STEINBECK, G
    LUDERITZ, B
    CIRCULATION, 1983, 67 (06) : 1368 - 1373
  • [34] THERMOLUMINESCENT DETECTOR PERFORMANCE IN LOW-DOSE SLOW-RATE ENVIRONMENTS
    STASSINOPOULOS, EG
    BRUCKER, GJ
    STAUBER, MC
    STEPHEN, JH
    CHANG, JY
    SANDERSON, TK
    APPLIED RADIATION AND ISOTOPES, 1988, 39 (04) : 303 - 309
  • [35] Prenatal diagnosis of slow-rate ventricular tachycardia using fetal electrocardiography
    Yumoto, Y
    Satoh, S
    Koga, T
    Nagata, H
    Nagamatsu, R
    Nakano, H
    PRENATAL DIAGNOSIS, 2004, 24 (06) : 463 - 467
  • [36] Reduced sensitivity to slow-rate dynamic auditory information in children with dyslexia
    Poelmans, Hanne
    Luts, Heleen
    Vandermosten, Maaike
    Boets, Bart
    Ghesquiere, Pol
    Wouters, Jan
    RESEARCH IN DEVELOPMENTAL DISABILITIES, 2011, 32 (06) : 2810 - 2819
  • [37] Multirate sampled-data systems: computing fast-rate models
    Wang, JD
    Chen, TW
    Huang, B
    JOURNAL OF PROCESS CONTROL, 2004, 14 (01) : 79 - 88
  • [38] OXYGEN-CONSUMPTION DURING PRANAYAMIC TYPE OF VERY SLOW-RATE BREATHING
    TELLES, S
    DESIRAJU, T
    INDIAN JOURNAL OF MEDICAL RESEARCH SECTION B-BIOMEDICAL RESEARCH OTHER THAN INFECTIOUS DISEASES, 1991, 94 : 357 - 363
  • [39] Efficient online algorithms for fast-rate regret bounds under sparsity
    Gaillard, Pierre
    Wintenberger, Olivier
    ADVANCES IN NEURAL INFORMATION PROCESSING SYSTEMS 31 (NIPS 2018), 2018, 31
  • [40] Cerebellar Purkinje Cells Generate Highly Correlated Spontaneous Slow-Rate Fluctuations
    Cao, Ying
    Liu, Yu
    Jaeger, Dieter
    Heck, Detlef H.
    FRONTIERS IN NEURAL CIRCUITS, 2017, 11