Are hip protectors correctly positioned in use?

被引:25
|
作者
Minns, R. J.
Marsh, A. -M.
Chuck, A.
Todd, J.
机构
[1] RMPD, Newcastle Gen Hosp, Newcastle Upon Tyne, Tyne & Wear, England
[2] Univ Hosp N Durham, OutPatients Dept, Durham, England
[3] Darlington Mem Hosp, Durham, England
关键词
hip protectors; hip fracture; older people; elderly; undergarment design; greater trochanter; soft tissue thickness; hip protector movement;
D O I
10.1093/ageing/afl186
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
There are many designs of hip protectors ranging from small elliptical shaped hard shell designs to large circular soft pads. They are held in position usually by being contained in a close fitting pocket on a garment that patients wear all the time they are at risk of sustaining a fracture of the hip if they fall onto the area of the greater trochanter (GT). It is important for the function of the hip protector that the pad element is positioned over the GT when the subject falls onto a surface such as the floor so as to provide the maximal protection by reducing the large forces transmitted to the femoral neck that lead to the fracture of the bone. In this study, anatomical measurements show where the GT is relevant to the centre of the hip protector, and position and movement studies have shown that generally the hard shell design of the hip protector lies posterior and proximal to the GT both for erect and flexed positions of the hip. The position of the GT relevant to the anterior superior iliac crest was established using ultrasound examinations on control and patients admitted with a fracture of the hip due to a fall. The diagonal surface distance for the three groups of test subjects was approximately 12 cm and a template was developed that could be used to locate the GT. A 'zone' of GT position and movement has been established relative to the anterior superior iliac crest, and designers of garments should ensure that this zone is within the area of protection provided by their hip protector pad design.
引用
收藏
页码:140 / 144
页数:5
相关论文
共 50 条
  • [31] Effectiveness of hip protectors -: Reply
    Meyer, G
    Warnke, A
    Mühlhauser, I
    BRITISH MEDICAL JOURNAL, 2003, 326 (7395): : 931 - 931
  • [32] The other side of hip protectors
    Becker, C
    Walter-Jung, B
    Nikolaus, T
    AGE AND AGEING, 2000, 29 (02) : 186 - 186
  • [33] Are hip protectors cost effective?
    Kumar, BA
    Parker, MJ
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (09): : 693 - 695
  • [34] Prevention of fractures by hip protectors
    Kiel, D. P.
    BONE, 2009, 44 (02) : S204 - S204
  • [35] This geriatrician wears hip protectors
    Sherman, Fredrick T.
    GERIATRICS-US, 2007, 62 (08): : 6 - 7
  • [36] Mechanical testing of hip protectors
    Nabhani, F
    Bamford, J
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2002, 124 (03) : 311 - 318
  • [37] Prevention of hip fracture in aged-care facilities with increased use of hip protectors in Japan.
    Koike, T
    Orito, Y
    Toyoda, H
    Tada, M
    Sugama, R
    Kobayashi, S
    Takaoka, K
    JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (09) : S291 - S292
  • [38] Effect on hip fractures of increased use of hip protectors in nursing homes:: cluster randomised controlled trial
    Meyer, G
    Warnke, A
    Bender, R
    Mühlhauser, I
    BMJ-BRITISH MEDICAL JOURNAL, 2003, 326 (7380): : 76 - 78A
  • [39] Anatomical hip model for the mechanical testing of hip protectors
    Derler, S
    Spierings, AB
    Schmitt, KU
    MEDICAL ENGINEERING & PHYSICS, 2005, 27 (06) : 475 - 485
  • [40] Hip protectors for preventing hip fractures in older people
    Santesso, Nancy
    Carrasco-Labra, Alonso
    Brignardello-Petersen, Romina
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2014, (03):