Are hip protectors correctly positioned in use?

被引:25
|
作者
Minns, R. J.
Marsh, A. -M.
Chuck, A.
Todd, J.
机构
[1] RMPD, Newcastle Gen Hosp, Newcastle Upon Tyne, Tyne & Wear, England
[2] Univ Hosp N Durham, OutPatients Dept, Durham, England
[3] Darlington Mem Hosp, Durham, England
关键词
hip protectors; hip fracture; older people; elderly; undergarment design; greater trochanter; soft tissue thickness; hip protector movement;
D O I
10.1093/ageing/afl186
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
There are many designs of hip protectors ranging from small elliptical shaped hard shell designs to large circular soft pads. They are held in position usually by being contained in a close fitting pocket on a garment that patients wear all the time they are at risk of sustaining a fracture of the hip if they fall onto the area of the greater trochanter (GT). It is important for the function of the hip protector that the pad element is positioned over the GT when the subject falls onto a surface such as the floor so as to provide the maximal protection by reducing the large forces transmitted to the femoral neck that lead to the fracture of the bone. In this study, anatomical measurements show where the GT is relevant to the centre of the hip protector, and position and movement studies have shown that generally the hard shell design of the hip protector lies posterior and proximal to the GT both for erect and flexed positions of the hip. The position of the GT relevant to the anterior superior iliac crest was established using ultrasound examinations on control and patients admitted with a fracture of the hip due to a fall. The diagonal surface distance for the three groups of test subjects was approximately 12 cm and a template was developed that could be used to locate the GT. A 'zone' of GT position and movement has been established relative to the anterior superior iliac crest, and designers of garments should ensure that this zone is within the area of protection provided by their hip protector pad design.
引用
收藏
页码:140 / 144
页数:5
相关论文
共 50 条
  • [1] Hip fracture with correctly positioned external hip protector
    Specht-Leible, N
    Oster, P
    AGE AND AGEING, 1999, 28 (05) : 497 - 497
  • [2] Proximal femoral fracture while wearing correctly applied hip protectors
    Cameron, ID
    Kurrle, SE
    Cumming, RG
    Quine, S
    AGE AND AGEING, 2000, 29 (01) : 85 - 86
  • [3] Social medical assessment of the use of hip protectors
    Fergenbauer, G.
    GESUNDHEITSWESEN, 2006, 68 (07) : 463 - 464
  • [4] Predictors of adherence with the recommended use of hip protectors
    Kurrle, SE
    Cameron, ID
    Quine, S
    JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2004, 59 (09): : 958 - 961
  • [5] Hip protectors
    Cameron, ID
    Kurrle, SE
    LANCET, 2003, 362 (9399): : 1940 - 1941
  • [6] Hip protectors
    Wilkinson, TJ
    Sainsbury, R
    AGE AND AGEING, 1998, 27 (02) : 89 - 90
  • [7] Hip protectors and hip fractures
    Jäntti, PO
    Aho, HJ
    Mäki-Jokela, PL
    Heikinheimo, RJ
    AGE AND AGEING, 1998, 27 (06) : 758 - 759
  • [8] Availability and use of hip protectors in residents of nursing homes
    J. Klenk
    S. Kurrle
    U. Rissmann
    A. Kleiner
    S. Heinrich
    H-H. König
    C. Becker
    K. Rapp
    Osteoporosis International, 2011, 22 : 1593 - 1598
  • [9] Availability and use of hip protectors in residents of nursing homes
    Klenk, J.
    Kurrle, S.
    Rissmann, U.
    Kleiner, A.
    Heinrich, S.
    Koenig, H-H.
    Becker, C.
    Rapp, K.
    OSTEOPOROSIS INTERNATIONAL, 2011, 22 (05) : 1593 - 1598
  • [10] Hip protectors - Acceptability of hip protectors was 35% at six months in the community
    McAughey, JM
    McAdoo, M
    BRITISH MEDICAL JOURNAL, 2002, 324 (7351): : 1455 - 1455