External quality assessment (EQA) for CoaguChek monitors

被引:25
|
作者
Jespersen, Joergen [2 ,3 ]
Poller, Leon [1 ]
van den Besselaar, A. M. H. P.
van der Meer, Felix J. M. [4 ]
Palareti, Gualtiero [5 ]
Tripodi, Armando [6 ]
Shiach, Caroline [7 ]
Keown, Michelle [1 ]
Ibrahim, Saied [1 ]
机构
[1] Univ Manchester, Fac Life Sci, EAA Cent Facil, Manchester M13 9PT, Lancs, England
[2] Univ So Denmark, Inst Publ Hlth, Dept Thrombosis Res, Esbjerg, Denmark
[3] Hosp SW Denmark, Dept Clin Biochem, Esbjerg, Denmark
[4] Leiden Univ, Med Ctr, Dept Thrombosis & Haemostasis, Thrombosis Serv Leiden, Leiden, Netherlands
[5] Univ Hosp St Orsola Malpighi, Dept Angiol & Blood Coagulat, Bologna, Italy
[6] Univ & IRCCS Maggiore Hosp, Mangiagalli & Regina Elena Fdn, Milan, Italy
[7] Manchester Royal Infirm, Dept Haematol, Manchester M13 9WL, Lancs, England
关键词
Oral anticoagultaion; external quality assessment; point-of-care monitors; INR deviation; accuracy; precision; EUROPEAN CONCERTED ACTION; INTERNATIONAL NORMALIZED RATIOS; PROTHROMBIN TIME MONITORS; POINT; ANTICOAGULATION; CALIBRATION; PRECISION; THERAPY; SYSTEM; MINI;
D O I
10.1160/TH09-10-0683
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Anticoagulant control facilities are being overwhelmed by requests for monitoring and large numbers of patients are not therefore receiving treatment. Procedures designed for point-of-care testing have therefore been developed, the most popular being the CoaguChek.The need for external quality assessment (EQA) of monitors used by patients in self-management has been stressed in a European Commission (EC) Directive. It would not however be feasible for all CoaguChek monitors to be enrolled in national or regional EQA schemes which take time to organise and analyse. The European Concerted Action on Anticoagulation (ECAA) has therefore evolved a simpler system. Its value has been assessed in collaboration with the European Concerted Action on Thrombosis (ECAT). 523 monitors were tested at nine clinics which asked patients to bring their CoaguChek instruments to be assessed with the ECAA/ECAT procedure based on a set of 5 plasma samples with certified international normalised ratios (INR). 15% or more deviation from the certified INR on a single certified plasma sample from the set was defined by the ECAA as the limit of acceptable performance. One hundred and six (20.3%) of the monitors tested showed significant deviation and higher than average incidence of significant INR deviations reported with one specific numbered lot of test strips. Recent ECAA/ECAT, Danish and Italian studies report regular EQA of CoaguChek monitors is essential. There is general agreement that this should be performed at reasonably frequent intervals, at six months or whenever there is a change of the manufacturer's test strips.
引用
收藏
页码:936 / 941
页数:6
相关论文
共 50 条
  • [31] External Quality Assessment (EQA) for Molecular Diagnostics of Zika Virus: Experiences from an International EQA Programme, 2016-2018
    Mantke, Oliver Donoso
    McCulloch, Elaine
    Wallace, Paul S.
    Yue, Constanze
    Baylis, Sally A.
    Niedrig, Matthias
    [J]. VIRUSES-BASEL, 2018, 10 (09):
  • [32] Development of a virtual web-based external quality assessment [EQA] scheme in cytopathology
    O'Shea, D.
    Doolan, C.
    Bolger, N.
    Cullen, R.
    Pilkington, L.
    Martin, C. M.
    Magee, D.
    Griffin, M.
    Gibbons, D.
    O'Leary, J. J.
    [J]. MODERN PATHOLOGY, 2008, 21 : 81A - 81A
  • [33] Development of a virtual web-based external quality assessment [EQA] scheme in cytopathology
    O'Shea, D.
    Doolaa, C.
    Bolger, M.
    Cullen, R.
    Pilkington, L.
    Martin, C. M.
    Magee, D.
    Griffins, M.
    Gibbons, D.
    O'Leary, J. J.
    [J]. LABORATORY INVESTIGATION, 2008, 88 : 81A - 81A
  • [34] Are external quality assurance (EQA) slide schemes a valid tool for the performance assessment of histopathologists?
    Parham, DM
    [J]. PATHOLOGY RESEARCH AND PRACTICE, 2005, 201 (02) : 117 - 121
  • [35] Italian National Survey of Blood Donors: External Quality Assessment (EQA) of Syphilis Testing
    Vulcano, Francesca
    Milazzo, Luisa
    Volpi, Sabrina
    Battista, Mara Maria
    Barca, Alessandra
    Hassan, Hamisa Jane
    Pimpinelli, Fulvia
    Giampaolo, Adele
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (03) : 753 - 757
  • [36] External quality assessment (EQA) and alternative assessment procedures (AAPs) in molecular diagnostics: findings of an international survey
    Payne, Deborah A.
    Russomando, Graciela
    Linder, Mark W.
    Baluchova, Katarina
    Ashavaid, Tester
    Steimer, Werner
    Ahmad-Nejad, Parviz
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (02) : 301 - 306
  • [37] Characterisation and evaluation of external quality assessment scheme serum - Discussion paper from the European external quality assessment (EQA) organisers working group C
    Middle, JG
    Libeer, JC
    Malakhov, V
    Penttila, I
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (02) : 119 - 130
  • [38] LAUNCH OF A NEW FECAL MOLECULAR EXTERNAL QUALITY ASSESSMENT (EQA) SCHEME BY UK NEQAS PARASITOLOGY
    Shrivastava, Jaya
    Chiodini, Peter L.
    Saez, Agatha C.
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2019, 101 : 156 - 156
  • [39] Nationwide external quality assessment (EQA) of EGFR testing in circulating tumor DNA: The French experience
    Denis, M.
    Vallee, A.
    Charpentier, S.
    Nanni-Metellus, I.
    Lacroix, L.
    Jovelet, C.
    Francilette, M.
    Fetique, D.
    Bellocq, J-P.
    Rouleau, E.
    [J]. ANNALS OF ONCOLOGY, 2017, 28
  • [40] External quality assessment (EQA) of Neisseria gonorrhoeae antimicrobial susceptibility testing in primary laboratories in Germany
    Regina Selb
    Klaus Jansen
    Matthias Eckardt
    Thalea Tamminga
    Sandra Dudareva
    Martyna Gassowski
    Ingeborg Graeber
    Eva Guhl
    Dagmar Heuer
    Susanne Buder