Contrast Sensitivity Comparison between Two Thin Lenses, Thinoptx® versus Acrismart®, after Micro Incision Cataract Surgery

被引:0
|
作者
Mirzaie, Mohammad [1 ]
Sadigh, Afshin Lotfi [1 ]
Mirzaie, Amaneh [1 ]
机构
[1] Tabriz Univ Med Sci, Alavi Hosp, Tabriz, Iran
来源
IRANIAN JOURNAL OF OPHTHALMOLOGY | 2009年 / 21卷 / 04期
关键词
Contrast Sensitivity; Spatial Frequencies; Micro Incision Cataract Surgery; Thin Lens; INTRAOCULAR-LENS;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Contrast sensitivity (CS) evaluation by SV-1000E chart in all spatial frequencies after micro incision cataract surgery (MICS) and its comparison between two thin lenses after optical correction in natural and glare conditions Methods: In this cross sectional study, 100 eyes having MICS with Dodick ARC phacolaser system were evaluated. 50 Thinoptx lenses and 50 Acrismart lenses were randomly implanted in the eyes. Uncorrected visual acuity (UCVA), best spectacle corrected visual acuity (BSCVA), refractive error and CS, in all spatial frequencies were measured three months after surgery. CSV-1000E chart with or without glare test was used for CS evaluation. Normalized measures of CS were compared between two thin lenses with Student's T-test. Results: CS profile was within the normal range in 52% of eyes and 48% of eyes had CS in lower than the normal range. The differences of CS in lower spatial frequencies [3 and 6 cycle/degree (c/d)] and higher spatial frequencies (12 and 18 c/d) between two lenses were not significant (P<0.449 and P<0.835, respectively). Conclusion: After implantation of two lenses by MICS, the CS in all spatial frequencies was similar.
引用
收藏
页码:72 / 75
页数:4
相关论文
共 24 条
  • [21] Comparison of two one-piece acrylic foldable intraocular lenses: Short-term change in axial movement after cataract surgery and its effect on refraction
    Goto, So
    Maeda, Naoyuki
    Ohnuma, Kazuhiko
    Noda, Toru
    [J]. PLOS ONE, 2022, 17 (08):
  • [22] Intraocular Pressure After Cataract Surgery Combined With Ab Interno Trabeculectomy Versus Trabecular Micro-bypass Stent: An Intrasubject Same-surgeon Comparison
    Weiner, Adam J.
    Weiner, Yotam
    Weiner, Asher
    [J]. JOURNAL OF GLAUCOMA, 2020, 29 (09) : 773 - 782
  • [23] Comparison Between Two Intraoperative Intravenous Loading Doses of Paracetamol on Pain After Minor Hand Surgery : Two Grams Versus One Gram
    Cornesse, D.
    Senard, M.
    Hans, G. A.
    Ledoux, D.
    Kirsch, M.
    Hick, G.
    Hallet, C.
    Joris, J.
    [J]. ACTA CHIRURGICA BELGICA, 2010, 110 (05) : 529 - 532
  • [24] Comparison of posterior capsule opacification rates between femto-second laser-assisted and micro-incision cataract surgery over 24 months; [Vergleich der Rate an hinteren Kapseltrübungen zwischen femtosekundenlaserassistierter und Mikroinzisions-Kataraktoperation über 24 Monate]
    Rabinovich M.
    Niegowski L.J.
    Bovet J.
    Aramburu del Boz A.
    Baumgartner J.-M.
    Gillmann K.
    [J]. Spektrum der Augenheilkunde, 2021, 35 (6) : 241 - 245