Contrast Sensitivity Comparison between Two Thin Lenses, Thinoptx® versus Acrismart®, after Micro Incision Cataract Surgery

被引:0
|
作者
Mirzaie, Mohammad [1 ]
Sadigh, Afshin Lotfi [1 ]
Mirzaie, Amaneh [1 ]
机构
[1] Tabriz Univ Med Sci, Alavi Hosp, Tabriz, Iran
来源
IRANIAN JOURNAL OF OPHTHALMOLOGY | 2009年 / 21卷 / 04期
关键词
Contrast Sensitivity; Spatial Frequencies; Micro Incision Cataract Surgery; Thin Lens; INTRAOCULAR-LENS;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Contrast sensitivity (CS) evaluation by SV-1000E chart in all spatial frequencies after micro incision cataract surgery (MICS) and its comparison between two thin lenses after optical correction in natural and glare conditions Methods: In this cross sectional study, 100 eyes having MICS with Dodick ARC phacolaser system were evaluated. 50 Thinoptx lenses and 50 Acrismart lenses were randomly implanted in the eyes. Uncorrected visual acuity (UCVA), best spectacle corrected visual acuity (BSCVA), refractive error and CS, in all spatial frequencies were measured three months after surgery. CSV-1000E chart with or without glare test was used for CS evaluation. Normalized measures of CS were compared between two thin lenses with Student's T-test. Results: CS profile was within the normal range in 52% of eyes and 48% of eyes had CS in lower than the normal range. The differences of CS in lower spatial frequencies [3 and 6 cycle/degree (c/d)] and higher spatial frequencies (12 and 18 c/d) between two lenses were not significant (P<0.449 and P<0.835, respectively). Conclusion: After implantation of two lenses by MICS, the CS in all spatial frequencies was similar.
引用
收藏
页码:72 / 75
页数:4
相关论文
共 24 条
  • [1] COMPARISON OF ACUITY, CONTRAST SENSITIVITY, AND DISABILITY GLARE BEFORE AND AFTER CATARACT-SURGERY
    RUBIN, GS
    ADAMSONS, IA
    STARK, WJ
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (01) : 56 - 61
  • [2] Immediate changes in intraocular pressure after clear corneal micro-incision versus small-incision cataract surgery
    Ken Hayashi
    Motoaki Yoshida
    Koichi Yoshimura
    [J]. Japanese Journal of Ophthalmology, 2014, 58 : 402 - 408
  • [3] Immediate changes in intraocular pressure after clear corneal micro-incision versus small-incision cataract surgery
    Hayashi, Ken
    Yoshida, Motoaki
    Yoshimura, Koichi
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2014, 58 (05) : 402 - 408
  • [4] Comparison of Morphological and Functional Endothelial Cell Changes after Cataract Surgery: Phacoemulsification Versus Manual Small-Incision Cataract Surgery
    Ganekal, Sunil
    Nagarajappa, Ashwini
    [J]. MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2014, 21 (01) : 56 - 60
  • [5] Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery
    Kurz, Sabine
    Krummenauer, Frank
    Thieme, Hagen
    Dick, H. Burkhard
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03): : 393 - 400
  • [6] Comparison of macular thickness and inflammatory cytokine levels after microincision versus small incision coaxial cataract surgery
    Hwang, Ho Sik
    Ahn, Ye Jin
    Lee, Hee Jin
    Kim, Man Soo
    Kim, Eun Chul
    [J]. ACTA OPHTHALMOLOGICA, 2016, 94 (03) : E189 - E194
  • [7] Comparison between two devices in the detection of corneal thickness changes after cataract surgery
    Maddalena De Bernardo
    Livio Vitiello
    Giulia Abbinante
    Ilaria De Pascale
    Luigi Capasso
    Giuseppe Marotta
    Nicola Rosa
    [J]. Scientific Reports, 11
  • [8] Comparison between two devices in the detection of corneal thickness changes after cataract surgery
    De Bernardo, Maddalena
    Vitiello, Livio
    Abbinante, Giulia
    De Pascale, Ilaria
    Capasso, Luigi
    Marotta, Giuseppe
    Rosa, Nicola
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [9] Correlation between contrast sensitivity and higher-order aberration based on pupil diameter after cataract surgery
    Yamaguchi, Takefumi
    Negishi, Kazuno
    Ohnuma, Kazuhiko
    Tsubota, Kazuo
    [J]. CLINICAL OPHTHALMOLOGY, 2011, 5 : 1701 - 1707
  • [10] Intraocular pressure rise after small incision cataract surgery: a randomised intraindividual comparison of two dispersive viscoelastic agents
    Rainer, G
    Menapace, R
    Findl, O
    Kiss, B
    Petternel, V
    Georgopoulos, M
    Schneider, B
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (02) : 139 - 142