An improved Current Voltage Transferring Device for high current high frequency measurement

被引:4
|
作者
Pattanadech, Norasage [1 ]
Kando, Masaaki [1 ]
机构
[1] King Mongkuts Inst Technol Ladkrabang, Fac Engn, Elect Engn Dept, Chalongkrung Rd, Bangkok 10520, Thailand
关键词
Current Voltage Transferring Device; Rogowski coil; Current transformer; Lightning current; Lightning current generator; Printed circuit board; SHUNTS;
D O I
10.1016/j.epsr.2017.06.015
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper represents the characteristics of the improved Current Voltage Transferring Device (CVTD) for high current measurement including lightning impulse currents. The improved CVTD has been developed from the prototype CVTD to provide exceptional characteristics for high current with high frequency measurement. The improved CVTD in h-shaped configuration is made of copper and aluminium. The relationship between input current and output voltages of the new CVTD was investigated with short and long duration lightning impulse currents to establish the empirical formulas. The typical impulse current generator was used to generate 8/20 mu s lightning impulse current with the amplitude of 940 A while the impulse generator with crowbar elements was utilized to generate 10/350 mu s lightning impulse current with magnitude of 30.2 kA for the experiment. The lightning impulse current measurement characteristics of the CVTD and Rogowski coil were examined. From the experiments, the new improved CVTD shows the superior characteristics to measure the impulse currents with very fast rise time. Besides, nanosecond pulses superimposed on the lightning impulse currents were detected by only the improved CVTD. According to the experiments, there is no doubt that the new improved CVTD is a superior one for high current with high frequency measurement especially lightning impulse currents. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:767 / 773
页数:7
相关论文
共 50 条
  • [31] High-frequency combined converter with low voltage and high current input and high voltage-output
    Shi, Jianjiang
    Zhang, Jihai
    Zhang, Jianguo
    He, Xiangning
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2007, 22 (08): : 13 - 17
  • [32] Optical current measurement system for high-voltage applications
    Cruden, A.
    Michie, C.
    Madden, I.
    Niewczas, P.
    McDonald, J.R.
    Andonovic, I.
    Measurement: Journal of the International Measurement Confederation, 1998, 24 (02): : 97 - 102
  • [33] MEASUREMENT OF VOLTAGE ACROSS A HIGH-CURRENT DIODE.
    Zakutin, V.V.
    Nasonov, N.N.
    Shenderovich, A.M.
    1600, (19):
  • [34] Characteristic analysis of shunt for high voltage direct current measurement
    Pan, Feng
    Xu, Yan
    Xiao, Xia
    Xu, Ken
    Ren, Shiyan
    MEASUREMENT, 2012, 45 (03) : 597 - 603
  • [35] OPTICAL TECHNIQUE FOR MEASUREMENT OF CURRENT AT HIGH-VOLTAGE - REPLY
    ROGERS, AJ
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1973, 120 (07): : 800 - 800
  • [36] Vessel Sealing Device Using Microwave and High Frequency Current
    Rakhmadi, Aditya
    Saito, Kazuyuki
    Sekine, Masashi
    Sugiyama, Masashi
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2021, 5 (02): : 108 - 114
  • [37] VERY HIGH ISOLATION ac CURRENT MEASUREMENT DEVICE.
    Anon
    IBM technical disclosure bulletin, 1985, 28 (02): : 596 - 597
  • [38] Tailoring High-Voltage, High-Current Thyristors for Very High Frequency Switching
    Sanders, Howard
    Waldron, John
    2016 IEEE INTERNATIONAL POWER MODULATOR AND HIGH VOLTAGE CONFERENCE (IPMHVC), 2016, : 179 - 182
  • [39] FIBER SENSOR FOR THE SIMULTANEOUS MEASUREMENT OF CURRENT AND VOLTAGE IN A HIGH-VOLTAGE SYSTEM
    RAJKUMAR, N
    KUMAR, VJ
    SANKARAN, P
    APPLIED OPTICS, 1993, 32 (07): : 1225 - 1228
  • [40] Improved methodology for high-frequency low-current measurement of grounding rod impedance
    Llovera, Pedro
    Antonio Lliso, Juan
    Fuster, Vicente
    Quijano, Alfredo
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 1954 - 1960