Comparison of intragastric pressure between endotracheal tube and supraglottic airway devices in laparoscopic hepatectomy A randomized, controlled, non-inferiority study

被引:1
|
作者
Ahn, Jin Hee [1 ]
Jeong, Jiseon [2 ]
Kang, Se Hee [2 ]
Yeon, Ji Eun [1 ]
Cho, Eun A. [1 ]
Choi, Gyu Sung [3 ]
Kim, Jong Man [3 ]
Kim, Gaab Soo [2 ]
机构
[1] Kangbuk Samsung Hosp, Dept Anaesthesiol & Pain Med, Seoul, South Korea
[2] CHA Univ Korea, Dept Anaesthesiol & Pain Med, Ilsan Med Ctr, Coll Med, Pocheon Si, South Korea
[3] Sungkyunkwan Univ, Samsung Med Ctr, Dept Gen Surg, Sch Med, Seoul, South Korea
关键词
airway management; hepatectomy; laparoscopic surgery; laryngeal mask; supraglottic device; LARYNGEAL MASK AIRWAY; GASTROESOPHAGEAL-REFLUX; SORE THROAT; ASPIRATION; LMA; VENTILATION; TRIAL; RISK;
D O I
10.1097/MD.0000000000026287
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Supraglottic airway (SGA) devices do not definitively protect the airway from regurgitation of gastric contents. Increased gastric pressure and long operation time are associated with development of complications such as aspiration pneumonia. The aim of this study was to compare intragastric pressure between second-generation SGA and endotracheal tube (ETT) devices during long-duration laparoscopic hepatectomy. Methods: A total of 66 patients was randomly assigned to 2 groups; 33 patients each in the ETT and SGA groups. Intragastric pressure was continuously measured via a gastric drainage tube with a three-way stopcock connected to the pressure monitoring device. Normal saline was added to the end of the gastric drainage tube at each operation time point. Results: Intragastric pressure during pneumoperitoneum was no different between the 2 groups (P = .146) or over time (P = .094). The mean (standard deviation [SD]) pH of the SGA tip measured after operation was 6.7 (0.4), and a pH <4 was not observed. Relative risk of postoperative complications was significantly higher in the ETT group relative to the SGA group (sore throat, 5.5; cough,13.0). Conclusions: Use of SGA devices does not further increase intragastric pressure, even during prolonged upper abdominal laparoscopic surgery. Also, the frequency of postoperative sore throat and cough was significantly lower when the second-generation SGA device was used.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Randomized controlled trial comparing the supraglottic airway to use of an endotracheal tube in sinonasal surgery
    Adams, Austin S.
    Wannemuehler, Todd J.
    Hull, Benjamin
    Wu, Jeffanie
    Chandra, Rakesh K.
    VonWahlde, Kate
    Shotwell, Matthew S.
    Harvey, Stephen
    Higgins, Michael
    McQueen, Kelly
    Turner, Justin H.
    [J]. INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2018, 8 (08) : 877 - 882
  • [2] Comparison of the Baska and I-gel supraglottic airway devices: a randomized controlled study
    Kara, Duygu
    Sarikas, Cafer Mutlu
    [J]. ANNALS OF SAUDI MEDICINE, 2019, 39 (05) : 302 - 308
  • [3] Comparison of supraglottic airway device and endotracheal tube in former preterm infants receiving general anesthesia: a randomized controlled trial
    Hu, Pin-Yang
    Chang, Yu-Tang
    Yang, Shu-Ting
    Wu, Ching-Shu
    Cheng, Kuang-, I
    Su, Miao-Pei
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01):
  • [4] Comparison of two doses of intrathecal morphine in laparoscopic donor hepatectomy: A randomized double-blinded non-inferiority trial
    Lee, Seungwon
    Kang, Ryung A.
    Choi, Gyu-Seong
    Kim, Jong Man
    Gwak, Mi Sook
    Lee, Sangmin Maria
    Kim, Gaab Soo
    Kim, Ah Hyun
    Ko, Justin Sangwook
    [J]. CLINICAL TRANSPLANTATION, 2023, 37 (08)
  • [5] Comparison between supraglottic airway devices and endotracheal tubes in patients undergoing laparoscopic surgery A systematic review and meta-analysis
    Park, Sun Kyung
    Ko, Geum
    Choi, Geun Joo
    Ahn, Eun Jin
    Kang, Hyun
    [J]. MEDICINE, 2016, 95 (33)
  • [6] Comparison of early postoperative recovery between laryngeal mask airway and endotracheal tube in laparoscopic cholecystectomy A randomized trial
    Kang, Se Hee
    Park, MiHye
    [J]. MEDICINE, 2019, 98 (25) : e16022
  • [7] Computational fluid dynamics comparison of the upper airway velocity, pressure, and resistance in cats using an endotracheal tube or a supraglottic airway device
    Zamora-Perarnau, Carla
    Malve, Mauro
    Fernandez-Parra, Rocio
    [J]. FRONTIERS IN VETERINARY SCIENCE, 2023, 10
  • [8] Comparison of the Jcerity Endoscoper Airway with the LMA supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial
    Zhou, Junfei
    Li, Lu
    Wang, Fang
    Lv, Yunqi
    [J]. BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [9] Comparison of the Jcerity Endoscoper Airway with the LMA supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial
    Junfei Zhou
    Lu Li
    Fang Wang
    Yunqi Lv
    [J]. BMC Anesthesiology, 22
  • [10] Comparison of silicone double-lumen tube and polyvinyl chloride single-lumen tube in fiberoptic tracheal intubation on a difficult airway model: a randomized controlled non-inferiority trial
    Seyoon Kang
    Yun Jeong Chae
    Dae Hee Kim
    Se Young Bae
    Ji Young Yoo
    [J]. Scientific Reports, 13