Comparison of the Jcerity Endoscoper Airway with the LMA supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial

被引:1
|
作者
Zhou, Junfei [1 ]
Li, Lu [1 ]
Wang, Fang [2 ]
Lv, Yunqi [1 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Anesthesiol Pain & Perioperat Med, Zhengzhou 450052, Peoples R China
[2] Zhengzhou Univ, Dept Pain Med, Affiliated Hosp 2, Zhengzhou, Peoples R China
关键词
Laryngeal mask airway; Airway management; Cerebral aneurysm embolization; Anesthesiology; LARYNGEAL MASK AIRWAY; ENDOVASCULAR TREATMENT; PROSEAL; INTUBATION; EFFICACY; SAFETY;
D O I
10.1186/s12871-022-01666-w
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Jcerity Endoscoper Airway is a new back-open endoscopic laryngeal mask airway device with a unique design. Our study sought to compare the implantation, ventilation quality and complications of JEA (Jcerity Endoscoper airway) versus LMA (Laryngeal Mask Airway) Supreme in the procedure of cerebral aneurysm embolization. Methods: In this prospective, randomised clinical trial, 182 adult patients with American Society of Anesthesiologists class I-II scheduled for interventional embolization of cerebral aneurysms were randomly allocated into the Jcerity Endoscoper airway group and the LMA Supreme group. We compared success rate of LMA implantation, ventilation quality, airway sealing pressure, peak airway pressure, degree of blood staining, postoperative oral hemorrhage, sore throat and other complications between the groups. Results: There were no significant differences between the groups in terms of one-time success rate of LMA implantation, ventilation quality, airway sealing pressure or airway peak pressure. However, LMA Supreme group showed a higher degree of blood staining than the JEA group when the laryngeal mask airway was removed (P=0.04), and there were also more oral hemorrhages and pharyngeal pain than JEA group (P=0.03, P=0.02). No differences were observed between groups in terms of other airway complications related to the LMA. Conclusions: The JEA could not only achieve comparable one-time success rate of implantation and quality of ventilation as the LMA Supreme, but also have lower blood staining degree of mask and less sore throat in patients undergoing perioperative anticoagulation for cerebral aneurysm interventional embolization.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of the Jcerity Endoscoper Airway with the LMA supreme for airway management in patients undergoing cerebral aneurysm embolization: a randomized controlled non-inferiority trial
    Junfei Zhou
    Lu Li
    Fang Wang
    Yunqi Lv
    [J]. BMC Anesthesiology, 22
  • [2] Comparison of the Jcerity endoscoper airway and the endotracheal tube in endoscopic esophageal variceal ligation: a prospective randomized controlled trial
    Le Zhang
    Lu Li
    Jun Wang
    Can Zhao
    Erxian Zhao
    Yanrong Li
    Yunqi Lv
    [J]. Scientific Reports, 13 (1)
  • [3] Comparison of the Jcerity endoscoper airway and the endotracheal tube in endoscopic esophageal variceal ligation: a prospective randomized controlled trial
    Zhang, Le
    Li, Lu
    Wang, Jun
    Zhao, Can
    Zhao, Erxian
    Li, Yanrong
    Lv, Yunqi
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01):
  • [4] Comparison of the LMA Supreme™ with the LMA Proseal™ for airway management in patients anaesthetized in prone position
    Lopez, A. M.
    Valero, R.
    Hurtado, P.
    Gambus, P.
    Pons, M.
    Anglada, T.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2011, 107 (02) : 265 - 271
  • [5] Comparison of the I-gel Laryngeal Mask Airway With the LMA-Supreme for Airway Management in Patients Undergoing Elective Lumbar Vertebral Surgery
    Kang, Fang
    Li, Juan
    Chai, XiaoQing
    Yu, JinGui
    Zhang, HuaMing
    Tang, ChaoLiang
    [J]. JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2015, 27 (01) : 37 - 41
  • [6] Comparison of intranasal and nebulized dexmedetomidine for premedication in pediatric patients: A non-inferiority randomized controlled trial
    Verma, Shilpi
    Bhatia, Pradeep Kumar
    Sharma, Vandana
    Mohammed, Sadik
    Saran, Anita
    [J]. JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2022, 38 (04) : 617 - 623
  • [7] A prospective randomized controlled trial of the Baska® mask and the LMA Supreme® in patients undergoing laparoscopic cholecystectomy
    Belena, J. M.
    Nunez, M.
    Alvarez-Manzanedo, R.
    Fernandez-Lanza, V
    Vidal, A.
    [J]. ACTA ANAESTHESIOLOGICA BELGICA, 2020, 71 (01) : 23 - 28
  • [8] Comparison of LMA Supreme™ with i-geI™ and LMA ProSeal™ in children for airway management during general anaesthesia: A meta-analysis of randomized controlled trials
    Bhattacharjee, Sulagna
    Som, Anirban
    Maitra, Souvik
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2017, 41 : 5 - 10
  • [9] Comparison of the supraglottic airway device BlockBusterTM and laryngeal mask airway Supreme in anaesthetised, paralyzed adult patients: a multicenter randomized controlled trial
    Gao, Xue
    Liu, Ju-Hui
    Chen, Chun-Mei
    Wang, Yong
    Wang, Zhong-Yu
    Yan, Chun-Ling
    Zuo, Ming-Zhang
    Cao, Yu
    Qiao, Xin
    Huang, Ya-Qi
    Liu, Pei-Chang
    Zhang, Hui
    Zhang, Jia-Qiang
    Shen, Jun-Mei
    Li, Chao
    Wang, Yi
    Sun, Yan-Yan
    Song, Jian-Nan
    Zhang, Xi-Zhe
    Zhang, Yun-Long
    Luo, Xiao-Ting
    Wu, Lu-Nan
    Zhang, Ye
    Shi, Li
    Zhang, Yuan
    Xue, Fu-Shan
    Tian, Ming
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (08) : 649 - 656
  • [10] Comparison of intragastric pressure between endotracheal tube and supraglottic airway devices in laparoscopic hepatectomy A randomized, controlled, non-inferiority study
    Ahn, Jin Hee
    Jeong, Jiseon
    Kang, Se Hee
    Yeon, Ji Eun
    Cho, Eun A.
    Choi, Gyu Sung
    Kim, Jong Man
    Kim, Gaab Soo
    [J]. MEDICINE, 2021, 100 (24) : E26287