This study discusses the behavior of reinforced concrete (RC) walls reinforced with different types of ferrocement composites under concentric and eccentric loading. The study incorporated experimental examination and nonlinear finite element analysis of ten RC walls with dimensions of 1000 mm in height, 1500 mm in width, and 150 mm in depth with RC footing with dimensions 1900 mm X 500 mm X 200 mm. The specimens were divided into two groups, one examined under concentric load and the other examined under eccentric load with eccentricity of 50 mm. Also, the structural behavior of the tested walls was validated with numerical development of a finite element model utilizing Ansys 2019-R1 software. Expanded or glass fiber wire mesh ferrocement tested specimens under concentric and eccentric line compression loading exhibited enhanced ultimate loads compared to control specimens. Expanded steel wire mesh reinforcement increased the ductility ratio compared to glass fiber mesh reinforcement. Glass fiber wire mesh produced a higher first cracking load, serviceability load, load carrying capacity, and energy absorption compared to expanded wire mesh. Good agreement between numerical and experimental results in first cracking load, load-carrying capacity, crack pattern, and deflection was found. The agreement between the experimental load carrying capacity and non linear finite element (NLFE) ones is about 86 % with coefficient of variance equals 0.003 and standard deviation of 0.06. The finite element analysis gave suitable estimation for the structural performance of nonlinear ferrocement RC walls. (C) 2021 The Author(s). Published by Elsevier Ltd.
引用
收藏
页数:19
相关论文
共 50 条
  • [11] Behavior of RC columns confined with CFRP sheet under eccentric loading
    Jing, D. H.
    Cao, S. Y.
    Sun, N.
    [J]. ISISS 2005: Innovation & Sustainability of Structures, Vol 1-3, 2005, : 2002 - 2012
  • [12] Behaviour of PVC encased reinforced concrete walls under eccentric axial loading
    Havez, Amr Abdel
    Wahab, Noran
    Al-Mayah, Adil
    Soudki, Khaled A.
    [J]. STRUCTURES, 2016, 5 : 67 - 75
  • [13] Experimental and analytical study of TRM strengthened brickwork walls under eccentric compressive loading
    Bernat, Ernest
    Gil, Lluis
    Roca, Pere
    Escrig, Christian
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2013, 44 : 35 - 47
  • [14] THE BEHAVIOR OF RC CONCRETE SPECIMEN WRAPPED BY FERROCEMENT COMPOSITES
    Ghogare, Amol V.
    Kondraivendhan, B.
    [J]. Indian Concrete Journal, 2023, 97 (12): : 30 - 36
  • [15] Investigation of mechanical behavior of RC columns strengthened with glass fiber-reinforced polymer under eccentric loading
    Lab. of Coastal and Offshore Eng., Dalian Univ. of Technol., Dalian 116023, China
    [J]. 1600, 87-93 (October 2004):
  • [16] Behavior of precast ferrocement thin walls under cyclic loading: an experimental and analytical study
    Bedoya-Ruiz, D.
    Ortiz, G. A.
    Alvarez, D. A.
    [J]. INGENIERIA E INVESTIGACION, 2014, 34 (01): : 29 - 35
  • [17] MASONRY WALLS UNDER CENTRIC OR ECCENTRIC NORMAL FORCE
    SCHWARTZ, J
    THURLIMANN, B
    [J]. BRICK AND BLOCK MASONRY, VOLS 1-3, 1988, : 420 - 434
  • [18] The Behavior of Infill Walls in RC Frames Under Combined Bidirectional Loading
    Misir, Ibrahim Serkan
    Ozcelik, Ozgur
    Girgin, Sadik Can
    Yucel, Umut
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2016, 20 (04) : 559 - 586
  • [19] Behavior of Reinforced Stone Dust Walls Under Strip Loading
    Kandolkar, Sumitra S.
    Mandal, J. N.
    [J]. ADVANCES IN CIVIL ENGINEERING MATERIALS, 2015, 4 (01): : 1 - 30
  • [20] Behavior of RC columns strengthened with different CFRP systems under eccentric loading
    Quiertant, Marc
    Clement, Jean-Luc
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (02) : 452 - 460