Turbo spin-echo diffusion-weighted MR of ischemic stroke

被引:0
|
作者
Lovblad, KO
Jakob, PM
Chen, Q
Baird, AE
Schlaug, G
Warach, S
Edelman, RR
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA USA
[2] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Neurol, Boston, MA USA
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PURPOSE: Our objective was to determine whether a multisection technique, diffusion-weighted half-Fourier single-shot turbo spin-echo (BASTE:) imaging, can compensate for the drawbacks common to other diffusion-weighted techniques; specifically, the need for echo-planar technology and the presence of susceptibility artifacts in areas close to the skull base, METHODS: Forty subjects who were referred to the stroke service with signs of acute (less than 24 hour) neurologic dysfunction were included in this prospective study, MR imaging of the brain was performed with diffusion-weighted echo-planar and diffusion-weighted HASTE sequences, The images obtained with both sequences were analyzed for the presence of hyperintensities corresponding to ischemic lesions as well as for the presence of image artifacts and distortions, RESULTS: Diffusion-weighted HASTE images showed areas of hyperintensity corresponding to the infarcts present on diffusion-weighted echo-planar imaging studies without distortion or susceptibility artifacts in all the patients who had a stroke, Twelve patients had no acute ischemic lesions; of these, five had other findings, six had normal findings, and in one patient, a hyperintensity seen on diffusion-weighted echo-planar images proved to be an artifact on diffusion-weighted HASTE images, CONCLUSIONS: Diffusion-weighted HASTE is equal to diffusion-weighted echo-planar imaging in the detection of early ischemia, Because of the absence of significant image distortions and other artifacts, diffusion-weighted HASTE permits fast multiplanar imaging in artifact-prone regions, such as the posterior fossa and the inferior frontal and temporal lobes, Diffusion imaging can be performed on conventional systems with strengths of 1.5 T that do not have echo-planar imaging capabilities.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 50 条
  • [21] Intravoxel Incoherent Motion Diffusion-Weighted Imaging of Lung Cancer: Comparison Between Turbo Spin-Echo and Echo-Planar Imaging
    Wan, Qi
    Lei, Qiang
    Wang, Peng
    Hu, Jianfeng
    Zhang, Tianjing
    Yu, Deng
    Li, Xinchun
    Liang, Changhong
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (03) : 334 - 340
  • [22] Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck
    Ryoji Mikayama
    Hidetake Yabuuchi
    Shinjiro Sonoda
    Koji Kobayashi
    Kazuya Nagatomo
    Mitsuhiro Kimura
    Satoshi Kawanami
    Takeshi Kamitani
    Seiji Kumazawa
    Hiroshi Honda
    [J]. European Radiology, 2018, 28 : 316 - 324
  • [23] Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck
    Mikayama, Ryoji
    Yabuuchi, Hidetake
    Sonoda, Shinjiro
    Kobayashi, Koji
    Nagatomo, Kazuya
    Kimura, Mitsuhiro
    Kawanami, Satoshi
    Kamitani, Takeshi
    Kumazawa, Seiji
    Honda, Hiroshi
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (01) : 316 - 324
  • [24] MR imaging of the rotator cuff mechanism: Comparison of spin-echo and turbo spin-echo sequences
    Sonin, AH
    Peduto, AJ
    Fitzgerald, SW
    Callahan, CM
    Bresler, ME
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) : 333 - 338
  • [25] Differences in apparent diffusion coefficients between normal brain echo-planar images and turbo spin-echo diffusion-weighted images with distortion correction
    Takatsu, Yasuo
    Nakamura, Masafumi
    Sagawa, Hajime
    Suzuki, Yuichi
    Mori, Nobuyuki
    Motegi, Shunichi
    Miyati, Tosiaki
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2022, 149
  • [26] Artifact-robust diffusion-weighted whole-body imaging with background suppression at 3 T using improved turbo spin-echo diffusion-weighted imaging
    Suzuki, Makoto
    Morita, Satoru
    Goto, Yasuhiro
    Tadenuma, Hitoshi
    Nishina, Yu
    Yoneyama, Masami
    Tanaka, Isao
    Sakai, Shuji
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1094):
  • [27] T2-WEIGHTED MR-IMAGING OF THE CHEST - COMPARISON OF ELECTROCARDIOGRAPH-TRIGGERED CONVENTIONAL AND TURBO SPIN-ECHO AND NONTRIGGERED TURBO SPIN-ECHO SEQUENCES
    HADDAD, JL
    ROFSKY, NM
    AMBROSINO, MM
    NAIDICH, DP
    WEINREB, JC
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 325 - 329
  • [28] MR evaluation of rotator cuff tears: Comparison of turbo spin-echo STIR and fat-suppressed turbo spin-echo T2-weighted images
    Chun, KA
    Ahn, B
    Kim, YJ
    Kim, KT
    [J]. RADIOLOGY, 1999, 213P : 376 - 376
  • [29] Sources of functional apparent diffusion coefficient changes investigated by diffusion-weighted spin-echo fMRI
    Jin, Tao
    Zhao, Fuqiang
    Kim, Seong-Gi
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1283 - 1292
  • [30] Evaluation of apparent diffusion coefficient of two-dimensional BLADE turbo gradient- and spin-echo diffusion-weighted imaging with a breast phantom
    Akiko Ohki
    Hajime Sagawa
    Mami Iima
    Masako Kataoka
    Yasutaka Fushimi
    Kun Zhou
    [J]. Radiological Physics and Technology, 2023, 16 : 118 - 126